Objective. Students will conduct an end-to-end simulated HVAC inspection on a full training system or residential host site, complete a professional field report section, and receive structured feedback mapped to credential exam competency areas.
This lesson, its worked examples and its practice questions has not yet been verified by a credentialed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
This lesson brings together every HVAC skill you have developed. You will inspect a complete residential HVAC system from end to end, document your findings, and write a professional report section—all under timed, realistic conditions. Performing well here directly prepares you for the HVAC content areas tested on the InterNACHI CPI and ASHI ACI credential exams and for the practical competencies required by most state licensing boards.
HVAC inspection is not maintenance or repair—you observe and report; you do not open sealed refrigerant circuits, remove electrical panel covers without authorization, or bypass any control. Before beginning:
Work through the system in a logical, repeatable order so you miss nothing and can explain your route in the report.
1. Thermostat and controls. Set the thermostat to call for heating, then cooling, and verify that the system responds. Note the thermostat type (manual, programmable, smart), its location, and any labeling issues.
2. Heating unit. Observe the heat exchanger area for rust, corrosion, or evidence of cracking—use your flashlight and inspection mirror at the burner compartment. Check the flue pipe connection, slope, material, and clearances. Record the fuel type, approximate age from the data plate, and BTU rating if visible. Use the combustible-gas detector along accessible gas supply lines. Measure supply-air temperature with the IR thermometer at a register and return-air temperature at the filter grille; a properly operating forced-air furnace typically produces a measurable temperature rise across the heat exchanger.
3. Cooling unit. Inspect the outdoor condensing unit: fins, refrigerant line insulation on the suction line, electrical disconnect, clearance to vegetation and structures, and concrete pad levelness. At the indoor air handler, check the evaporator coil drain pan for standing water or biological growth, confirm the condensate drain line is clear and properly terminated, and verify the refrigerant lines are insulated where exposed.
4. Air distribution. Walk every accessible space. Note supply and return register locations, visible duct material and condition, insulation on ducts in unconditioned spaces, and any obvious disconnections or crushing. Flex duct should not be kinked or compressed.
5. Ventilation terminations. Confirm that bath, kitchen, and mechanical exhaust fans terminate outside the building envelope—not into an attic or crawlspace. Verify that combustion air and flue terminations meet clearance requirements from windows, doors, and grade.
Take a photograph or make a labeled sketch for every defect before you move on. Your camera or smartphone is a primary documentation tool, not an afterthought. Note the exact location (e.g., "north wall of basement, furnace flue collar") so anyone reading the report can find the item without your help.
Mark every finding on your field checklist in real time. Relying on memory after the walk-through is the leading cause of omissions on both actual inspections and credential exams.
You have 45 minutes after the walk-through. The HVAC section of a professional report must include:
InterNACHI Standards of Practice and ASHI Standards of Practice both require that you report the systems you inspect, their condition, and deficiencies that affect safety or function. Neither standard requires you to determine the cause of every defect or to provide cost estimates—stay within scope.
The InterNACHI CPI and ASHI ACI exams both include questions on HVAC systems covering heating equipment types and their inspection points, cooling system components, distribution and ventilation, and report-writing standards. The credential-mapped debrief after this practice session will identify any content gaps so you can focus your exam study. State licensing exams draw from the same knowledge base and often weight safety-related findings heavily—exactly the category where automatic retests apply in this lesson.
Your instructor will score two things independently. First, defect detection: you must identify at least five of the six planted defects. Each defect is worth points regardless of severity—a minor finding you miss counts the same as a major one, because real inspectors must report everything within scope. Second, your report narrative is scored for correct scope, accurate terminology, and appropriate recommended actions. A safety protocol failure—touching a live component, skipping PPE, or using the gas detector improperly—triggers an automatic full retest regardless of your defect score.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →