Objective. Students will evaluate a ductwork system and building ventilation components for installation defects, leakage indicators, and blocked pathways, and connect findings to health and energy-efficiency impacts.
This lesson, its worked examples and its practice questions has not yet been verified by a credentialed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
The duct system carries conditioned air from the HVAC equipment to every room and returns it back for reconditioning. When ducts are damaged, disconnected, or improperly installed, the consequences reach beyond comfort: energy is wasted, moisture migrates into building cavities, and indoor air quality (IAQ) suffers. As a home inspector you are not an HVAC technician, but you are expected to identify visible defects, explain their significance, and recommend the appropriate follow-up action.
Disconnected flex duct is one of the most consequential findings in an attic or crawlspace. Conditioned air dumps directly into an unconditioned space, heating or cooling the attic instead of the living area. Look for detached collars, pulled inner liners, or flex duct lying loose without connection to a boot or plenum.
Crimped or kinked flex duct restricts airflow significantly. Flex duct must maintain a gradual curve with a minimum bending radius specified by the manufacturer; a tight kink can reduce airflow by a large fraction, starving rooms of conditioned air and forcing the system to work harder.
Missing duct insulation in unconditioned spaces causes condensation in cooling season (when cold air inside meets warm, humid air outside the duct) and heat loss in heating season. Ducts running through attics, crawlspaces, or garages should be insulated to the level required by the applicable energy code.
Blocked return-air grilles — furniture pushed against a grille, a filter installed backwards, or a grille clogged with debris — reduce system airflow, causing pressure imbalances, hot and cold spots, and strain on the blower motor.
Improperly terminated bath exhaust fans are a chronic moisture problem. A fan that terminates in the attic instead of through the roof or an exterior wall deposits warm, humid air directly into the attic structure, promoting mold growth and wood decay. Termination must be through the building envelope to the exterior.
Clothes-dryer duct terminated in attic or crawlspace is both a moisture hazard and — because of the lint — a fire hazard. Dryer exhaust must always terminate directly to the exterior of the building.
Many residential HVAC systems include components beyond the basic filter:
When writing report language, match your words to your evidence. "Evidence of biological growth on the humidifier media — recommend evaluation and service by a qualified HVAC technician" is defensible. Claiming air is unsafe to breathe goes beyond what a visual inspection can support.
ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings, establishes minimum ventilation requirements for low-rise residential buildings. Inspectors are not required to perform engineering calculations, but familiarity with the standard's concepts — whole-building ventilation, local exhaust ventilation in bathrooms and kitchens, and proper termination — helps you recognize deficiencies.
Local exhaust is required in bathrooms and kitchens to remove moisture, combustion byproducts, and odors at the source. Key inspection checks:
1. Is an exhaust fan (or operable window) present in each bathroom?
2. Does the kitchen have a range hood or exhaust fan?
3. Does every exhaust duct terminate outside the building envelope — not into the attic, crawlspace, wall cavity, or soffit?
4. Are duct paths free of disconnects, excessive length, or tight bends that would impair flow?
On a floor plan walkthrough, trace each exhaust path from grille to termination point. Mark any location where you cannot confirm proper termination as a deficiency requiring further evaluation.
Every defect finding needs three elements: what you observed, where you observed it, and what action you recommend. Inspection reports for home inspectors typically offer one of three actions: monitor (minor issue, owner aware), recommend repair (clear defect within a contractor's normal scope), or recommend licensed evaluation (safety concern, active system problem, or finding beyond the visual scope of inspection). Matching the action to the severity of the finding protects your client and protects you.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →