HLT-RADI64-04 · Lesson 5 · 28 clock hours · lab

Positioning Errors and Anatomical Criteria

Objective. Students identify positioning errors in chest, extremity, and spine radiographs by comparing images against published anatomical inclusion and alignment criteria, and state the corrective positioning adjustment for each error found.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

Why Positioning Criteria Matter

A radiograph is only clinically useful when the anatomy of interest is shown clearly, completely, and without distortion. Published anatomical criteria—found in references such as Bontrager's Textbook of Radiographic Positioning and Related Anatomy—define exactly what must appear on each projection: which structures must be included, how they should be aligned, and what landmarks should be centered or visible. When a radiograph falls short of those criteria, the interpreting provider may miss pathology, order a repeat exposure, or make an incorrect diagnosis. Repeat exposures add unnecessary radiation dose to the patient, so getting positioning right the first time is both a quality and a safety obligation.

As a limited-scope or entry-level radiographer, your responsibility is to recognize when a finished image meets criteria and, when it does not, to identify the specific error and know how to correct it before—or instead of—repeating the exposure.

Common Categories of Positioning Error

Rotation occurs when the patient's body part is not properly aligned with the image receptor (IR). On a PA chest, rotation is detected by comparing the medial ends of the clavicles: they should be equidistant from the spinous processes of the thoracic vertebrae. If one clavicular head is closer, the patient was rotated toward that side. On an AP pelvis, the obturator foramina should appear symmetric; asymmetry indicates rotation.

Tilt is different from rotation. Tilt describes a superior-to-inferior angling of the part rather than a left-to-right twist. On a lateral lumbar spine, tilt shows as the posterior cortices of the vertebral bodies not being superimposed.

Incorrect centering means the central ray (CR) was directed to the wrong anatomical landmark. For a PA chest, the CR is typically centered to the midsagittal plane at the level of the inferior angle of the scapulae (approximately T7). If the CR is too high, the lung apices may be clipped; if too low, the costophrenic angles may be cut off.

Inadequate collimation means the radiation field is larger than necessary for the anatomy of interest. This increases scatter radiation, reduces image contrast, and delivers unnecessary dose to adjacent tissues. Proper collimation should be visible as a border of unexposed film (or digital equivalent) around the anatomy.

Part positioning errors include failure to achieve the correct projection angle, failure to remove superimposing structures, or failure to place a joint in the required flexion or extension. For example, on a lateral knee, the femoral condyles should be superimposed; a gap indicates the leg was not truly lateral.

Anatomy not fully included means a required structure is clipped at the edge of the image. For extremities, joints proximal and distal to a long-bone fracture site must be included on at least one projection per most protocols.

Evaluating a PA Chest Radiograph

For the PA chest, the accepted anatomical criteria include:

If you see fewer than ten posterior ribs, the patient likely did not fully inspire, or the exposure was taken at the wrong phase of breathing. If the scapulae overlie the lungs, the patient's arms were not correctly positioned.

Evaluating a Lateral Lumbar Spine Radiograph

For the lateral lumbar spine:

If the posterior vertebral body margins are not superimposed (double-shadowed posterior cortices), the patient was rotated. The correction is to adjust the patient's pelvis until a true lateral position is achieved, sometimes using positioning sponges under the waist to keep the spine parallel to the IR.

Stating the Corrective Adjustment

Identifying an error is only half the task. You must also state the specific corrective action in terms a colleague could act on:

Vague statements like "reposition the patient" are not acceptable. Name the direction of error and the direction of the fix.

Radiation Safety During Image Evaluation Labs

When using a live radiographic unit in lab:

Patient identification and correct laterality markers (R or L) must be confirmed before every exposure. A mislabeled radiograph can lead to wrong-side surgery or missed diagnosis—both serious patient safety events.

Key terms9

Anatomical criteriaPublished standards specifying which structures must appear, how they must be aligned, and what landmarks must be visible for a radiographic projection to be considered diagnostically acceptable.
RotationA positioning error in which the body part is twisted around its long axis relative to the image receptor, causing asymmetric appearance of normally symmetric structures.
Central ray (CR)The center of the X-ray beam; it must be directed to a specific anatomical landmark and at a specified angle to produce the intended projection.
CollimationThe restriction of the X-ray beam to the area of clinical interest using adjustable lead shutters; inadequate collimation increases patient dose and reduces image contrast.
Image receptor (IR)The device that captures the X-ray beam after it passes through the patient; may be a digital detector plate or cassette.
TiltA positioning error in which the body part is angled superiorly or inferiorly relative to the IR rather than twisted side to side.
SuperimpositionThe intentional or unintentional overlapping of anatomical structures on a radiographic image; in a true lateral position, paired structures (e.g., femoral condyles) should superimpose perfectly.
Corrective positioning adjustmentA specific, directional change to patient position, CR angle, or IR placement made to bring a repeat exposure into compliance with anatomical criteria.
Repeat exposureAn additional radiographic exposure taken because the initial image did not meet diagnostic criteria; each repeat adds radiation dose and should be avoided through careful initial positioning.
In class: Image gallery walk: 20 printed or displayed radiographs are posted around the lab; students rotate to each, record the projection, identify whether positioning criteria are met, and note any error (e.g., rotation, incorrect centering, inadequate collimation). · Lab simulation: students position a volunteer or anthropomorphic phantom for a PA chest and lateral lumbar spine, produce the image, and self-evaluate using the anatomical criteria checklist before instructor review. · Group case study: three images with subtle positioning errors are presented; teams compete to correctly identify all errors and propose corrections, with instructor adjudication.
Materials: Radiographic unit, anthropomorphic phantom or volunteer model, positioning sponges, PACS workstation, Bontrager Textbook of Radiographic Positioning and Related Anatomy (current edition), anatomical criteria checklists
Check: Gallery-walk answer sheet and self-evaluation checklist; student must correctly identify the positioning status (acceptable or error) on ≥16 of 20 gallery images and correctly note the corrective action on all identified errors to pass.

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

Radiographic Procedures / Image Evaluation
1. On a PA chest radiograph, the medial end of the right clavicle is closer to the thoracic spinous processes than the left. Which positioning error does this indicate?
Radiographic Procedures / Image Evaluation
2. A lateral lumbar spine radiograph shows double posterior cortical shadows on the vertebral bodies. What is the most likely cause?
Radiographic Procedures / Image Evaluation
3. A PA chest radiograph shows only eight posterior ribs visible above the diaphragm. Which corrective action is most appropriate?
Radiographic Procedures / Image Evaluation
4. For a lateral knee radiograph, the primary criterion confirming a true lateral position is:
Radiographic Procedures / Image Evaluation
5. Why must the scapulae be projected outside the lung fields on a PA chest radiograph?
Radiographic Procedures / Positioning
6. A student produces a lateral lumbar spine radiograph and notes that the L5–S1 disc space is not visible. Which is the best corrective action?
Radiation Protection / Patient Safety
7. Inadequate collimation on a radiograph is a patient safety concern primarily because it:
Radiographic Procedures / Image Evaluation
8. During a gallery walk, a student evaluates an AP wrist radiograph. The distal radius and ulna are visible but the carpal bones are cut off at the distal edge of the image. Which positioning status and correction are correct?