Objective. Students will solve trade math problems involving whole numbers, fractions, decimals, percentages, ratios, unit conversion between imperial and metric systems, and algebraic manipulation of Ohm's Law and the power equation (P = IV) as they arise in PV system sizing and wiring calculations.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional engineer or master tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Every PV installation involves numbers. You calculate how many modules fit on a roof, whether a wire is sized correctly, and whether a string of modules will exceed an inverter's maximum input voltage. Errors in these calculations can damage equipment, create fire hazards, or result in a system that underperforms. Accurate trade math is therefore a safety skill, not just a bookkeeping task.
Most PV calculations use decimals because electrical values are rarely round numbers. A module might produce 9.83 A of short-circuit current or have an efficiency of 20.4%. Practice moving between these forms. When adding or subtracting decimals, align the decimal points. When multiplying, count total decimal places in both factors and place the decimal that many positions from the right in your answer.
Fractions appear less often in field calculations, but understanding them helps when reading efficiency ratings expressed as ratios. A system that converts 20 out of every 100 watts of sunlight into electricity has an efficiency of 20/100, or 0.20, or 20%.
Percentage means "per hundred." To convert a percentage to a decimal, divide by 100 (move the decimal two places left). To convert a decimal to a percentage, multiply by 100.
In PV work, percentages describe efficiency, derate factors, and temperature-related losses. For example, if a 400 W module operates at 85% of its rated output due to shading and soiling, its actual output is 400 × 0.85 = 340 W. Knowing how to apply a percentage as a multiplier is one of the most frequently used skills on the job.
A ratio compares two quantities. The DC-to-AC ratio (also called the inverter loading ratio) compares the total DC nameplate capacity of the array to the AC output rating of the inverter. A ratio of 1.2:1 means for every 1 W of inverter capacity you have 1.2 W of modules. Setting up a proportion lets you solve for an unknown when three of the four values are known, using cross-multiplication.
The US electrical trade uses both systems. Wire lengths may be measured in feet; module dimensions appear in millimeters; irradiance is expressed in watts per square meter (W/m²). You must convert fluently.
Key relationships to memorize:
To convert, multiply by the correct conversion factor written as a fraction so the unwanted unit cancels. For example, to convert 15 feet to meters: 15 ft × (1 m / 3.281 ft) = 4.57 m.
Ohm's Law states the relationship among voltage (V, in volts), current (I, in amperes), and resistance (R, in ohms):
V = I × R
You can rearrange it algebraically to solve for any unknown:
In wiring calculations, you use Ohm's Law to find voltage drop across a conductor. A high voltage drop reduces system efficiency and can be a code compliance issue. Always confirm that conductor sizing keeps voltage drop within acceptable limits for the system design.
Electrical power (P, in watts) equals current times voltage:
P = I × V
Rearrange to find current or voltage when power is known:
This equation is central to PV sizing. If a charge controller must handle an array producing 3,000 W at 48 V, the current it must carry is 3,000 / 48 = 62.5 A. Undersizing a component based on a math error is a genuine safety hazard—overcurrent can cause insulation failure, arcing, and fire.
Modules connected in series (a string) add their voltages. A string of 10 modules each with an open-circuit voltage (Voc) of 45.0 V produces a string Voc of 450 V. However, module voltage changes with temperature: voltage rises as the module gets colder and drops as it gets hotter. Manufacturers provide a temperature coefficient for Voc (typically expressed in %/°C or V/°C). You apply this coefficient to the lowest expected temperature to find the maximum string voltage and confirm it does not exceed the inverter's maximum DC input voltage—a critical safety check to prevent equipment damage and arc-flash risk.
Always estimate your answer before calculating. If you expect roughly 400 W and your calculator shows 40,000 W, you made a decimal or unit error. Double-check entries and watch for common mistakes: forgetting to convert kW to W, or mixing up Voc and Vmp. Treat a number that seems unreasonably large or small as a red flag and recheck your work.
Trade math for solar PV is applied arithmetic and basic algebra in an electrical context. Master percentages, unit conversion, Ohm's Law, and P = IV and you will have the quantitative foundation for every sizing, wiring, and safety calculation in this program and on the NABCEP exams.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →