Objective. Students will correctly don, seal-check, use, and doff a self-contained breathing apparatus (SCBA) and demonstrate understanding of when each class of respiratory protection is required under fumigation label and OSHA standards.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Fumigants such as methyl bromide and phosphine are acutely toxic gases. Exposure to even brief concentrations above the permissible exposure limit (PEL) can cause serious injury or death. Because these gases are invisible and often odorless at dangerous concentrations, you cannot rely on your senses to warn you. Your respiratory protection system is your primary defense against a life-threatening hazard every time you work near or inside a treated structure.
Fumigation is one of the few agricultural and structural pest control tasks where OSHA's respiratory protection standard, 29 CFR 1910.134, and the fumigant product label both impose mandatory, specific equipment requirements. The label is a legal document under FIFRA. Following it is not optional.
Self-Contained Breathing Apparatus (SCBA) supplies its own air from a compressed-air cylinder carried by the wearer. It provides the highest level of protection and is required any time you enter a structure that has been sealed and gassed, or any time atmospheric concentration is unknown. SCBA units used in fumigation must be NIOSH-approved and are classified as atmosphere-supplying respirators. They operate in either open-circuit (exhaled air vented to atmosphere) or closed-circuit (air recycled) mode; open-circuit units are standard in structural fumigation.
Supplied-Air Respirators (SAR), also called airline respirators, deliver air through a hose from a remote compressor or cylinder bank. They are used in some fumigation support roles where mobility is limited and continuous air supply from a stationary source is acceptable.
Air-Purifying Respirators (APR), including half-face and full-face units fitted with appropriate cartridges, remove contaminants by filtering ambient air. They require oxygen concentrations of at least 19.5 percent to be safe. APRs are never acceptable inside a sealed, gassed structure. They may be appropriate during certain outdoor tasks—always check the specific fumigant label for the exact cartridge type and permissible conditions.
Assigned Protection Factors (APF) define how much a respirator reduces your exposure. OSHA 29 CFR 1910.134 assigns APF values to each respirator class. SCBA in pressure-demand mode carries a high APF; half-face APRs carry a much lower APF. When the fumigant label requires a certain protection level, you must use a respirator whose APF meets or exceeds what is needed.
Donning sequence (manufacturer order governs; this is the general pattern):
1. Inspect cylinder pressure—verify adequate air supply before donning.
2. Open the cylinder valve fully.
3. Don the harness and position the cylinder.
4. Connect the regulator to the facepiece.
5. Don the facepiece; position and tighten head harness straps from the bottom up.
6. Perform a seal check.
Positive-pressure seal check: Cover the exhalation valve; exhale gently. The facepiece should bulge slightly and hold pressure. Any air leaking out at the face seal indicates a poor fit.
Negative-pressure seal check: Cover the inhalation port; inhale gently. The facepiece should collapse slightly toward your face and hold. Any air rushing in indicates a leak.
Always follow the SCBA manufacturer's specific seal-check procedure—it overrides any general description.
Buddy check: Before entry, your partner visually and physically inspects your unit: cylinder open, connections tight, PASS device armed, regulator functioning. You then check your partner. No one enters alone or without a buddy check completed.
Doff in a clean area after exiting the hazard zone. Loosen head harness straps from the top down, remove the facepiece, then remove the harness and cylinder. For emergency doff—if a facepiece is trapping you or malfunctioning—know the single-motion release points on your specific unit before you ever enter a structure.
The fumigant label specifies the complete PPE ensemble. Typical requirements include:
Do not assume one stage's PPE covers another. Read the label for each specific task phase.
Before you may use a respirator on a job, OSHA 29 CFR 1910.134 requires a medical evaluation to confirm you are physically able to wear respiratory protection, and annual fit testing for tight-fitting facepieces. These are employer obligations but your responsibility to complete. Fit testing and SCBA use cannot be skipped or self-certified.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →