Objective. Students will demonstrate correct step-off pad procedure, anti-contamination clothing donning and doffing sequence, and basic personnel decontamination technique while maintaining their own skin and clothing free of detectable contamination.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional engineer or master tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
In a nuclear plant, radioactive contamination means loose radioactive material that has spread to a surface, clothing, equipment, or the human body where it does not belong. Even small amounts of contamination on skin or clothing can deliver an unplanned radiation dose over time and can spread that material to clean areas of the plant or to the public. Contamination control is therefore one of the most fundamental radiation protection disciplines, and every nuclear worker — licensed or not — must perform entry and exit procedures correctly every single time.
The Radiological Controlled Area (RCA) is the boundary within which contamination hazards exist. You must treat every surface inside the RCA as potentially contaminated until monitoring proves otherwise.
Anti-contamination clothing, universally called anti-C clothing, is not a radiation shield. It does not stop gamma rays or neutrons. Its purpose is to keep radioactive particles off your skin and personal clothing so that when you leave the RCA you leave the contamination behind. Typical anti-C ensembles include:
All anti-C is single-use or laundered under controlled conditions. Never take anti-C clothing outside the plant's radiological waste or laundry stream.
The step-off pad is a clean mat placed at the boundary of a contaminated area. It marks the exact point where your anti-C clothing must be removed before your foot touches the clean floor. One side of the pad faces the contaminated area; the other faces the clean area. You must step off the pad toward clean only once your feet are free of contaminated boot covers. Think of the pad as a physical enforcement of the contamination boundary.
Don anti-C in a clean area just outside the RCA entry point. The correct order prevents you from contaminating the outer layers with your hands while putting on inner layers:
1. Inner boot covers over personal shoes
2. Inner gloves (cotton or thin latex)
3. Coveralls — zip fully; tuck sleeves over inner gloves
4. Hood — seat snugly; tuck into coverall collar
5. Outer boot covers — tape to coverall leg if required by procedure
6. Outer gloves — pull cuff over coverall sleeve
7. Respirator (when required) — seal-check before entering
Your partner verifies each step against the written procedure. Never skip the buddy check.
Doffing — removing anti-C at the exit — is the highest-risk moment for self-contamination. The roll-away technique keeps potentially contaminated outer surfaces folded inward so they never touch clean skin or clothing:
1. While still on the contaminated side, remove the respirator (if worn) and place it in a designated bag or waste container.
2. Remove outer gloves by peeling from the wrist, rolling contaminated side inward; dispose in waste container.
3. Remove outer boot covers one at a time, lifting each foot and stepping it directly onto the step-off pad — never back to the contaminated floor.
4. Remove coveralls and hood together by rolling downward from the shoulders, keeping the contaminated outside rolled inward; avoid shaking. Step out of coveralls onto the pad.
5. Remove inner boot covers and step off the pad to the clean side with bare (or personal shoe) feet.
6. Remove inner gloves by peeling, rolling contaminated side inward.
7. Place all waste in the radiological waste bag or container at the pad.
At every step, keep your hands away from your face and avoid touching your personal clothing with outer layers.
After doffing, proceed immediately to the frisker station and perform a self-frisk with a Geiger-Mueller (GM) thin-window detector:
If contamination is found on skin, RP staff will direct decontamination — typically gentle washing with lukewarm water and mild soap, repeated until count rates return to background or an acceptable release level. Do not scrub aggressively; this opens pores and can drive contamination in.
Answer each question, then check it. Nothing is recorded; this is your own practice.