Objective. Students will establish peripheral IV access and IO access on task trainers and administer simulated medications via IV push, IV drip, and IO routes, meeting all steps of NREMT paramedic psychomotor skill sheets.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Establishing vascular access and delivering medications accurately are core paramedic competencies. Mastery requires correct technique, strict asepsis, and vigilance for complications at every step.
Intravenous (IV) and intraosseous (IO) access give you a direct route to the patient's circulatory system. In emergencies, speed and reliability matter—a secure, patent line can mean the difference between effective drug delivery and treatment failure. The NREMT paramedic psychomotor evaluation tests both routes because each has a distinct clinical role.
Equipment check first. Before touching the patient, confirm you have the correct catheter gauge, IV tubing primed with normal saline (NS), tape or a commercial securement device, and a functioning sharps container within reach.
1. Standard precautions. Don gloves. Eye protection is appropriate when splash risk exists.
2. Select a site. Prefer the antecubital fossa or a large forearm vein for emergencies. Avoid an arm with an arteriovenous fistula, injury, or infection.
3. Apply the tourniquet 3–4 inches proximal to the intended site. Ask the patient to open and close the fist if possible.
4. Prep the site. Cleanse with an alcohol wipe using a circular or back-and-forth motion; allow to dry fully—this is a critical infection-control step.
5. Insert the catheter bevel up at a 10–30-degree angle. Advance until you see a flash of blood in the hub, then lower the angle and advance the catheter off the needle into the vein.
6. Release the tourniquet before removing the needle to prevent excessive bleeding.
7. Remove the needle and immediately place it in the sharps container—never recap.
8. Confirm patency. Connect primed tubing, open the roller clamp briefly, and check for free flow and absence of swelling.
9. Secure the site. Apply tape or a commercial dressing; loop the tubing to reduce tension on the catheter.
10. Set the rate and document time, site, gauge, and patient response.
IO access delivers fluids and medications directly into the bone marrow, which drains into the venous system. It is indicated when IV access cannot be rapidly established in a critically ill or injured patient.
1. Select the site. Common sites include the proximal tibia (2 cm below the tibial tuberosity on the flat medial surface), distal tibia, and proximal humerus, depending on the device used.
2. Standard precautions as above.
3. Prep the site with antiseptic and allow to dry.
4. Insert the IO needle per the device manufacturer's instructions—most EMS systems use a powered driver (e.g., EZ-IO). Apply firm pressure and activate the driver until a decrease in resistance signals entry into the marrow space.
5. Confirm placement. Remove the stylet and confirm with: the needle standing upright without support, ability to aspirate marrow (not always possible), and free flow of flush without significant swelling.
6. Flush with NS (typically 10 mL for adults) to clear the needle and reduce resistance before medication administration. Warn conscious patients that IO flush and medication infusion can be painful; lidocaine IO flush is sometimes used per local protocol.
7. Secure the needle and connect IV tubing or a pressure bag—IO flow depends on gravity and pressure because bone marrow has resistance.
8. Document as with IV access.
IV push (bolus): Draw up the correct volume, clean the nearest injection port, inject at the rate specified by protocol, then flush the line to ensure the drug reaches the circulation.
IV drip (infusion): Spike the secondary bag, prime secondary tubing, and connect via a Y-site or secondary port. Set the pump or calculate a drip rate manually. Verify the rate is correct before leaving the patient.
IO administration: Use the same principles as IV push or drip. Because flow is slower, use a pressure bag or syringe push to ensure delivery. Follow each medication with a saline flush.
| Complication | Signs | Action |
|---|---|---||
| Infiltration | Swelling, pain, slowed flow at site | Stop infusion, remove catheter, apply warm compress, restart at new site |
| Dislodged line | Catheter backed out, no blood return | Stop infusion, reassess; if unsalvageable, remove and restart |
| Rate error | Pump alarm or incorrect volume delivered | Pause pump, recalculate, correct programming, reassess patient |
| IO dislodgement | Needle tilts, swelling in surrounding tissue | Remove, apply pressure, establish new access |