Objective. Students will configure BIOS/UEFI settings—boot order, secure boot state, memory operating speed, and IPMI/iDRAC/iLO network address—and demonstrate remote server power control from a management workstation.
This lesson, its worked examples and its practice questions has not yet been verified by an industry-certified professional or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Every server contains firmware that runs before the operating system loads. The older standard is BIOS (Basic Input/Output System); the modern replacement is UEFI (Unified Extensible Firmware Interface). UEFI supports drives larger than 2 TB, faster boot times, Secure Boot, and a graphical setup interface. In a data center you will encounter both, but new servers ship with UEFI by default. Regardless of which firmware a server uses, it is your entry point for hardware-level configuration that the OS cannot change.
Boot device priority tells the server which device to try first when starting: typically the primary SSD or hard drive array, followed by the network (PXE boot), then optical or USB. Set PXE boot last unless you are deliberately deploying an OS over the network, because an accidental network boot can stall a production server.
UEFI vs. Legacy (CSM) mode controls how the firmware hands off to the OS loader. Keep servers in UEFI mode unless the OS or hardware explicitly requires legacy mode; Secure Boot only works in UEFI mode.
Secure Boot validates that the OS bootloader is signed by a trusted authority before executing it. Enable Secure Boot on servers running supported OS versions to protect against bootkits and unauthorized code at startup.
Memory operating speed (DRAM frequency) is usually set to "Auto," which lets the firmware negotiate the highest speed the installed DIMMs and CPU memory controller support. A spec sheet may require you to set a specific speed for workload predictability or hardware qualification. Never set a speed higher than the DIMM's rated speed.
Unused onboard ports (unused SATA controllers, serial ports, embedded video when a PCIe GPU is present) should be disabled to reduce attack surface and free interrupt resources. Always document what you disable so the next technician knows the state.
Out-of-band (OOB) management lets you access a server's power controls, hardware sensors, and a virtual console even when the main OS is crashed, the server is powered off, or you are physically in a different building. It runs on a dedicated management controller with its own processor, memory, and network port—completely separate from the server's main CPUs and data NICs.
For OOB management to work, the management port must have a valid IP address, subnet mask, and default gateway on a dedicated management VLAN—separate from production traffic. You configure this address either inside the BIOS/UEFI setup screens or through the BMC's own setup utility (often reached during POST by pressing a key combination shown on screen).
Once the management IP is set and your workstation is on the same management network, open a browser, type the IP address, and log in with the administrator credentials. Inside the iDRAC or iLO interface you will find:
A remote power cycle is a routine task for a data center technician. The correct sequence is: (1) verify you are connected to the correct server by checking the service tag displayed in the management interface against the physical label; (2) attempt a graceful shutdown first unless the server is unresponsive; (3) confirm the physical power LEDs show the server is off before initiating power-on; (4) document the time, interface used, and reason in your configuration record.
Out-of-band management gives you the ability to cut power to a running server from across the room or across the country. Always confirm server identity before issuing any power command—a mistaken force-off on the wrong server can cause unplanned downtime and data loss. When physically working inside a server, follow lockout/tagout (LOTO) procedures: power down through the OS, then cut power at the PDU breaker and apply your lock before opening the chassis. OOB management does not eliminate the need for LOTO—the BMC still has standby power even when the server appears off. Wear an ESD wrist strap or use an ESD mat when handling circuit boards and DIMMs. Do not modify BIOS settings on a production server without a change-management approval and a rollback plan.
Answer each question, then check it. Nothing is recorded; this is your own practice.