13 courses · 1,350 clock hours · 6–9 mo full-time. Grading is competency-based: each course requires the written exam, a competent skills demonstration with zero safety faults, a signed log, and a passed safety audit; percentage weights only rank performance above the competency floor.
Shared first block for every VoTechWorks program. OSHA 10 (30 for construction management), first aid/CPR/AED, applied trade math and measurement, technical reading and writing, digital literacy, and career readiness. Completed before students enter the lab and live systems unsupervised.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| OSHA 10 and first-aid written exams | Written exam | 25% | OSHA card issued; CPR/AED card issued | Authorized outreach trainer exam plus AHA/Red Cross skills check. Accuracy · Safety · Communication · Professionalism |
| Applied math & measurement exam | Written exam | 25% | 70% | Timed exam: conversions, layout math, estimating from a drawing or recipe/order. Accuracy · Safety · Communication · Professionalism |
| Technical report | Project | 25% | Rubric ≥ 3 of 4 on every criterion | A written report on a real task from the trade: problem, standard, method, result. Accuracy · Safety · Communication · Professionalism |
| Employer panel interview | Oral / panel | 25% | Panel pass | Resume, 3-minute portfolio walk-through, and interview with two employer advisors. Accuracy · Safety · Communication · Professionalism |
Competency course in Rack & stack for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in Rack & stack and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Rack & stack: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for Rack & stack. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Rack & stack: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of Rack & stack against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Rack & stack: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Rack & stack: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing Rack & stack work. Standard met · Safety · Time · Quality/finish · Documentation |
Competency course in structured cabling & fiber for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in structured cabling & fiber and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Structured cabling & fiber: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for structured cabling & fiber. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Structured cabling & fiber: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of structured cabling & fiber against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Structured cabling & fiber: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Structured cabling & fiber: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing structured cabling & fiber work. Standard met · Safety · Time · Quality/finish · Documentation |
Competency course in power distribution for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in power distribution and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Power distribution: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for power distribution. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Power distribution: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of power distribution against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Power distribution: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Power distribution: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing power distribution work. Standard met · Safety · Time · Quality/finish · Documentation |
Competency course in cooling & airflow for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in cooling & airflow and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Cooling & airflow: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for cooling & airflow. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Cooling & airflow: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of cooling & airflow against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Cooling & airflow: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Cooling & airflow: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing cooling & airflow work. Standard met · Safety · Time · Quality/finish · Documentation |
Competency course in server/network hardware for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in server/network hardware and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Server/network hardware: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for server/network hardware. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Server/network hardware: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of server/network hardware against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Server/network hardware: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Server/network hardware: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing server/network hardware work. Standard met · Safety · Time · Quality/finish · Documentation |
Competency course in Linux basics for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in Linux basics and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Linux basics: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for Linux basics. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Linux basics: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of Linux basics against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Linux basics: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Linux basics: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing Linux basics work. Standard met · Safety · Time · Quality/finish · Documentation |
Competency course in monitoring & ticketing for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in monitoring & ticketing and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Monitoring & ticketing: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for monitoring & ticketing. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Monitoring & ticketing: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of monitoring & ticketing against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Monitoring & ticketing: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Monitoring & ticketing: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing monitoring & ticketing work. Standard met · Safety · Time · Quality/finish · Documentation |
Competency course in physical security for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in physical security and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Physical security: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for physical security. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Physical security: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of physical security against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Physical security: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Physical security: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing physical security work. Standard met · Safety · Time · Quality/finish · Documentation |
Competency course in safety for the Data Center Technician program. Instruction moves from demonstration to supervised practice to independent performance in the lab and live systems, measured against vendor documentation and industry standards. Students configure, secure and troubleshoot real work in safety and keep a lab notebook signed off by the instructor.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Safety: written exam | Written exam | 25% | 75% | Theory, terminology, standards and safety for safety. Multiple choice plus short calculation/interpretation items drawn from the certification body's task list. Standard met · Safety · Time · Quality/finish · Documentation |
| Safety: skills demonstration | Skills demonstration | 45% | Competent on every critical step; zero safety faults | Observed, timed performance of the core tasks of safety against a checklist. A critical-step miss or a safety fault stops the assessment; re-attempt after remediation. Standard met · Safety · Time · Quality/finish · Documentation |
| Safety: lab notebook | Log | 15% | Complete, signed, ≥ 90% attendance of lab hours | Daily entries: task, standard, method, result, time; instructor sign-off. Serves as hours evidence for the licensing/certifying body. Standard met · Safety · Time · Quality/finish · Documentation |
| Safety: safety audit | Safety audit | 15% | Pass/fail — must pass | Unannounced audit of PPE, housekeeping, lockout/guarding, and hazard communication while performing safety work. Standard met · Safety · Time · Quality/finish · Documentation |
An integrated, assessed piece of real work that draws on every trade course in Data Center Technician: planned, estimated, executed and documented by the student, reviewed by an employer advisor. Capstones are shown in the Student Yard or the Museum of VoTech where the work allows.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Capstone: finished work + documentation | Project | 60% | Rubric ≥ 3 of 4 on every criterion | Employer advisor + instructor score the finished work against the specification, the estimate, and the documentation package. Meets specification · Within estimate · Workmanship · Safety · Documentation |
| Capstone: portfolio | Portfolio | 20% | Complete | Photos/drawings/logs of every course skills demonstration plus the capstone, in the program portfolio format. Completeness · Organization · Evidence quality |
| Capstone: defense | Oral / panel | 20% | Panel pass | 15-minute presentation and questions from the panel. Explains decisions · Answers technical questions · Professional communication |
Supervised placement with an employer partner in Data Center Technician work. Hours are logged against the certifying body's task list; the employer evaluates against the same rubric used in the shop.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Employer evaluation | Skills demonstration | 70% | Satisfactory on every competency | Mid-point and final evaluation by the site supervisor on the program competency list. Competency · Safety · Attendance · Conduct · Initiative |
| Hours & task log | Log | 30% | Required hours complete and verified | Signed log of hours and tasks; verified by the registrar for the board/certifying body. Complete · Verified |
Structured preparation for BICSI Installer; CNet CDCTP; CompTIA A+; CompTIA Server+; OSHA 10: content review mapped to the exam blueprint, timed practice exams, practical-exam rehearsal, and registration/eligibility paperwork with the registrar.
Outcomes| Assessment | Type | Weight | Pass standard | Method & rubric |
|---|---|---|---|---|
| Mock certification exam (×2) | Mock certification exam | 100% | ≥ 80% on both | Full-length timed mocks built from the certifying body's published blueprint; second attempt after targeted review. Score · Time management |
The program completion credential(s). Sat at the school's authorized testing center or the body's test site; results recorded in the student record and reported in the annual outcomes report. Pass standard: Credential issued by the body.