Objective. Students will describe how a variable-voltage variable-frequency (VVVF) drive regulates motor speed and explain the role of the microprocessor controller in dispatching, door timing, and fault logging.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional engineer or master tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Older traction elevators used resistance banks or motor-generator sets to control speed. Modern elevators rely on a variable-voltage variable-frequency (VVVF) drive, sometimes called an AC drive or inverter drive. The VVVF drive accepts incoming AC power, converts it to DC inside a rectifier stage, then inverts it back to AC at precisely the voltage and frequency commanded by the controller. Because the speed of an AC induction motor is directly related to the frequency of its supply, the drive can ramp the motor smoothly from zero to full speed and back again—producing the soft starts and stops that passengers feel as comfort and that equipment feels as reduced mechanical stress.
1. Converter (Rectifier) Stage. The drive's input section takes three-phase line voltage and rectifies it into a DC bus voltage. Diode bridges or active transistor bridges are used depending on drive design. The DC bus is filtered by large capacitors that store energy and smooth out ripple.
2. DC Bus. The intermediate DC bus links the converter to the inverter. Bus voltage is monitored continuously. Regenerative drives can feed energy back to the building power system during descent or braking, improving energy efficiency.
3. Inverter Stage. Insulated gate bipolar transistors (IGBTs) switch the DC bus on and off thousands of times per second using pulse-width modulation (PWM). By varying the width of each pulse, the inverter synthesizes an AC waveform of any desired voltage and frequency. The microprocessor controller sends speed commands; the drive translates them into gate-firing signals for the IGBTs.
Drives are programmed through a keypad interface or software tool. Parameters are stored in non-volatile memory. The most important categories for elevator work include:
Never change parameter settings without written authorization from the authority having jurisdiction and in accordance with the manufacturer's documentation. Incorrect ramp settings can cause a car to overshoot a floor or slam into a buffer.
The main processor board is the brain of the elevator system. It runs the operating software that handles every decision the elevator makes:
The processor board communicates with the physical world through I/O boards that contain relay outputs, digital inputs, and analog channels. Hall call buttons, landing door interlocks, position encoder signals, and load-weighing inputs all connect to I/O boards. The I/O boards and the drive interface board exchange data with the main processor over an internal serial bus (often a proprietary protocol or a standard such as CAN bus). This reduces wiring compared to hard-wired relay logic and allows the controller to send and receive dozens of signals over a few conductors.
The drive interface board translates the processor's speed command (often a digital serial message or a ±10 V analog signal) into the format the VVVF drive expects, and returns drive status and fault data back to the processor.
1. Passenger presses the hall up button → I/O board reads the input and sends the call to the processor.
2. Processor dispatching algorithm selects the car and assigns a destination floor.
3. Processor commands doors to close → door operator receives the signal via I/O board.
4. Processor confirms the safety chain is intact and releases the brake.
5. Processor sends a speed profile command to the drive interface board.
6. Drive interface board forwards the speed reference to the VVVF drive.
7. VVVF drive ramps up frequency and voltage → motor accelerates the car.
8. As the car approaches the destination floor, the processor commands a deceleration ramp → drive reduces output frequency smoothly.
9. Car levels at the floor; brake sets; processor commands doors to open.
10. Fault log records the run data; processor waits for the next call.
Before working on any controller cabinet or drive: follow lockout/tagout (LOTO) procedures in accordance with OSHA requirements and your employer's energy-control program. The DC bus capacitors in a VVVF drive can hold a lethal charge for several minutes after input power is removed—always verify that bus voltage has discharged to a safe level with a calibrated meter before touching internal components. Wear appropriate PPE including arc-flash-rated gear when the hazard assessment requires it. Never bypass or jumper safety chain inputs to test drive parameters while the car is in service.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.