AGR-WATE71-02 · Lesson 2 · 12.5 clock hours · lab
The pH Scale, Acids, Bases, and Alkalinity
Objective. Students will measure pH and alkalinity of water samples using a calibrated pH meter and titration, and explain why these parameters matter for corrosion control and disinfection.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Why pH and Alkalinity Matter to Operators
Every water and wastewater operator works with pH and alkalinity every shift. These two parameters control whether your disinfectant works, whether your pipes corrode, whether coagulation succeeds, and whether your treated water is safe to distribute. Licensing exams for Class I and Class II water and wastewater operators test these concepts directly, so a solid understanding is essential.
The pH Scale
pH is a measure of the hydrogen ion (H⁺) concentration in water. The scale runs from 0 to 14. A pH of 7.0 is neutral — pure water at room temperature. Values below 7.0 are acidic (more H⁺ ions); values above 7.0 are basic or alkaline (fewer H⁺ ions, more hydroxide OH⁻ ions).
The scale is logarithmic: each whole-number step represents a tenfold change in hydrogen ion concentration. Water at pH 5 has ten times more H⁺ than water at pH 6, and one hundred times more than water at pH 7. This logarithmic nature means small pH shifts can cause large chemical changes in your system.
Drinking water pH target: The EPA Secondary Maximum Contaminant Level recommends a pH range of 6.5–8.5 for aesthetic and corrosion-control reasons. The Lead and Copper Rule requires utilities to optimize pH (often in the 7.0–9.5 range, depending on the corrosion-control study) to minimize lead and copper leaching from plumbing.
Disinfection: Chlorine disinfection efficiency depends on pH. At lower pH, a higher fraction of chlorine exists as hypochlorous acid (HOCl), the more effective disinfectant form. At higher pH, hypochlorite ion (OCl⁻) dominates, which is far less effective. Operators must balance disinfection efficiency against corrosion control and regulatory requirements.
Wastewater treatment: Biological treatment processes (activated sludge, trickling filters) work best in a near-neutral pH range. Extreme pH kills the microorganisms doing the treatment.
Acids and Bases in Water Systems
An acid donates H⁺ ions in solution. Common acids operators encounter include carbonic acid (H₂CO₃, formed when CO₂ dissolves in water), sulfuric acid (used as a pH depressant and in lab titrations), and hydrofluoric acid (used in fluoridation). A base accepts H⁺ ions or donates OH⁻. Common bases include sodium hydroxide (caustic soda, used to raise pH), lime (calcium hydroxide), and soda ash (sodium carbonate).
When source water absorbs excess CO₂ — from groundwater contact with soil, from microbial respiration in a reservoir, or from acid rain — pH drops. This is one of the most common causes of low-pH events in distribution systems.
Alkalinity: The Buffer Capacity
Alkalinity is the capacity of water to neutralize acids — its buffering ability. It is not the same as pH. A water sample can have a high pH but low alkalinity (easy to push pH down with a small acid dose) or a moderate pH with high alkalinity (resists pH change).
Alkalinity in natural waters comes mainly from bicarbonate (HCO₃⁻), carbonate (CO₃²⁻), and hydroxide (OH⁻) ions. Results are reported in mg/L as CaCO₃ so that different contributing species can be compared on a common basis.
For operators, adequate alkalinity is critical for:
- Corrosion control — buffered water is less aggressive toward pipe materials.
- Coagulation — alum and ferric coagulants consume alkalinity; if natural alkalinity is too low, it must be supplemented (often with lime) so coagulation proceeds correctly.
- Biological nitrification — the process consumes alkalinity; wastewater operators monitor it to protect the microbial community.
Typical regulatory guidance suggests a minimum alkalinity for corrosion control purposes, though specific values depend on the corrosion-control study results for each system.
pH Meter Calibration
A pH meter measures the voltage across a glass electrode. Because electrode response drifts with temperature and age, two-point buffer calibration is required before each use. Standard buffer solutions at pH 4.00, 7.00, and 10.00 are commonly used. For most drinking water work, calibrate with pH 7 and pH 10 buffers. For acidic samples, use pH 4 and pH 7.
Calibration steps (general): Rinse the electrode with deionized water and blot dry. Immerse in the first buffer; adjust the meter to read that buffer's certified value. Rinse, blot, immerse in the second buffer; confirm or adjust. Document the calibration in your lab log with date, time, buffer lot numbers, temperature, and the reading obtained. A properly calibrated meter should read within ±0.05 pH units of the certified buffer value.
Alkalinity Titration Procedure
The standard titration for total alkalinity uses a dilute sulfuric acid titrant and endpoint indicators, following Standard Methods for the Examination of Water and Wastewater. Phenolphthalein indicator turns pink in alkaline solution and becomes colorless at approximately pH 8.3 (the P alkalinity endpoint). Bromcresol green turns from blue to yellow at approximately pH 4.5 (the T or total alkalinity endpoint). Total alkalinity is calculated from the volume of acid used to reach the bromcresol green endpoint.
Total alkalinity (mg/L as CaCO₃) = (A × N × 50,000) / mL sample
Where A = mL of acid titrant used to the total alkalinity endpoint, N = normality of the acid titrant, and 50,000 is the equivalent weight of CaCO₃ × 1,000.
Safety in the Lab
Before beginning any lab work, put on safety glasses, nitrile gloves, and a lab apron — this PPE is required for all work involving acids, bases, and chemical indicators. Sulfuric acid titrant, even dilute, is corrosive. If skin or eye contact occurs, flush immediately with large amounts of water for at least 15 minutes and notify the instructor. Never pipette by mouth. Keep buffer solutions capped when not in use to prevent CO₂ absorption, which shifts their pH. Dispose of all chemical waste according to your lab's waste disposal procedure — do not pour acids or unknown samples down the drain without instructor authorization.
Key terms10
pHA logarithmic scale (0–14) expressing the concentration of hydrogen ions in water; 7.0 is neutral, below 7.0 is acidic, above 7.0 is basic.
AlkalinityThe capacity of water to neutralize acid, primarily due to bicarbonate, carbonate, and hydroxide ions; reported in mg/L as CaCO₃.
BufferA solution that resists changes in pH when small amounts of acid or base are added; high-alkalinity water acts as a buffer in distribution systems.
Hypochlorous acid (HOCl)The more biologically active form of free chlorine disinfectant, dominant at lower pH values; less effective as pH rises.
Two-point buffer calibrationThe process of setting a pH meter to read accurately by checking and adjusting it against two certified buffer solutions of known pH before use.
TitrationA laboratory technique in which a reagent of known concentration (titrant) is added to a sample until a reaction endpoint (often shown by an indicator color change) is reached, allowing calculation of the unknown concentration.
Normality (N)A measure of reagent concentration expressed as equivalents per liter; used in alkalinity titration calculations with sulfuric acid titrant.
Phenolphthalein endpointThe pH 8.3 endpoint in an alkalinity titration where phenolphthalein indicator changes from pink to colorless, measuring carbonate and hydroxide alkalinity (P alkalinity).
Corrosion controlTreatment strategies — often involving pH and alkalinity adjustment — used to reduce the leaching of metals such as lead and copper from pipes and plumbing into drinking water.
CO₂ intrusionThe dissolution of carbon dioxide gas into water, forming carbonic acid and lowering pH; a common cause of low-pH conditions in groundwater and distribution systems.
Worked examples4
1. Calculate the total alkalinity of a water sample. A 100 mL sample was titrated to the bromcresol green endpoint using 7.20 mL of 0.02 N sulfuric acid titrant.
- Write the formula: Total Alkalinity (mg/L as CaCO₃) = (A × N × 50,000) / mL sample
- Identify the values: A = 7.20 mL of acid used, N = 0.02 N, sample volume = 100 mL
- Multiply A × N × 50,000: 7.20 × 0.02 × 50,000 = 7.20 × 1,000 = 7,200
- Divide by sample volume in mL: 7,200 / 100 = 72
- State the result with units: Total Alkalinity = 72 mg/L as CaCO₃
Answer: 72 mg/L as CaCO₃
2. A distribution system is reading pH 6.2. The operator decides to add soda ash (sodium carbonate) to raise pH. The target dose is 10 mg/L. The system flow rate is 500 gallons per minute (gpm). How many pounds of soda ash per day must be fed?
- Convert flow to MGD (million gallons per day): 500 gpm × 1,440 min/day = 720,000 gal/day = 0.72 MGD
- Use the chemical feed formula: Feed (lb/day) = Dose (mg/L) × Flow (MGD) × 8.34 lb/gal
- Substitute values: Feed = 10 × 0.72 × 8.34
- Calculate: 10 × 0.72 = 7.2; then 7.2 × 8.34 = 60.05 lb/day
- Round appropriately: approximately 60.0 lb/day of soda ash
Answer: Approximately 60.0 lb/day of soda ash
3. During two-point pH meter calibration, a student immerses the electrode in the pH 7.00 buffer and the meter reads 7.08 before adjustment. After adjustment the meter reads 7.01. Is this calibration acceptable, and what should be recorded in the lab log?
- Identify the acceptance criterion: the calibrated reading must be within ±0.05 pH units of the certified buffer value.
- Compare the post-adjustment reading to the buffer value: |7.01 − 7.00| = 0.01, which is less than 0.05.
- Conclusion: the calibration is acceptable (0.01 < 0.05).
- Record in the lab log: date, time, buffer pH value and lot number, temperature during calibration, initial meter reading (7.08), adjusted reading (7.01), and the operator's initials.
Answer: Yes, the calibration is acceptable. The adjusted reading of 7.01 is within ±0.05 of the 7.00 buffer value (difference = 0.01). All calibration data must be entered in the lab log.
4. A second 100 mL sample uses 3.60 mL of 0.02 N H₂SO₄ to reach the phenolphthalein endpoint (P alkalinity) and a total of 9.00 mL to reach the bromcresol green endpoint (T alkalinity). Calculate P alkalinity and total alkalinity, both in mg/L as CaCO₃.
- P alkalinity uses volume to phenolphthalein endpoint: A_P = 3.60 mL
- P Alkalinity = (3.60 × 0.02 × 50,000) / 100 = (3,600) / 100 = 36 mg/L as CaCO₃
- Total alkalinity uses total volume to bromcresol green endpoint: A_T = 9.00 mL
- Total Alkalinity = (9.00 × 0.02 × 50,000) / 100 = (9,000) / 100 = 90 mg/L as CaCO₃
- State both results clearly.
Answer: P alkalinity = 36 mg/L as CaCO₃; Total alkalinity = 90 mg/L as CaCO₃
The math in this lesson1
Learners compute total alkalinity (A × N × 50,000) ÷ mL sample = 72 mg/L as CaCO₃.
A-SSE.1
In class: Instructor demo: calibrate a benchtop pH meter using two-point buffer calibration; students repeat the calibration individually and record results in their lab log. · Titration exercise: students titrate at least three water samples of varying alkalinity using sulfuric acid titrant and phenolphthalein/bromcresol green indicators, then calculate total alkalinity in mg/L as CaCO3. · Case-study analysis: given a set of low-pH readings from a distribution system, students identify potential causes (CO2 intrusion, acid rain, treatment overshoot) and propose one corrective chemical addition, showing the dose calculation.
Materials: Benchtop pH meters, buffer solutions (pH 4, 7, 10), burettes, volumetric flasks, sulfuric acid titrant (0.02 N), phenolphthalein and bromcresol green indicators, water samples, Standard Methods for the Examination of Water and Wastewater (current edition), safety glasses, nitrile gloves, lab aprons.
Check: Lab log entry graded: pH calibration within ±0.05 of buffer value; alkalinity titration results within ±5 mg/L of instructor-prepared known sample; dose calculation correct to within 5% (all three criteria must be met to pass).
Practice check8
Answer each question, then check it. Nothing is recorded; this is your own practice.
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.