🚧 Under construction — VoTechWorks is being built. A free tech program — complimentary, as our commitment to get America working.
voTechWorksGrade 13 · a vocational technology learning center, by urbanicity
newSchoolWorks.com › VoTechWorks › Agriculture, Environment & Public Service › Pest Control Technician › Termite and Wood-Destroying Organism Identification, Inspection, and Control › Lesson 3
AGR-PEST78-04 · Lesson 3 · 6 clock hours · lab

Liquid Termiticide Application: Soil Treatment and Barrier Methods

Objective. Students will correctly calculate a liquid termiticide dilution, set up application equipment, and apply a simulated soil barrier treatment to a practice trench, demonstrating label compliance and full PPE use throughout.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

Why Liquid Termiticide Soil Barriers Matter

Liquid termiticides applied to the soil create a continuous chemical zone — commonly called a treated zone or barrier — between the structure's foundation and termite colonies living in the ground. When the barrier is complete and applied at the label-specified rate, foraging termites contact the product before they can reach wood. Two major chemical classes exist: repellent termiticides, which termites detect and avoid, and non-repellent termiticides, which termites cannot detect and therefore pass through, picking up a lethal or transfer dose. The selection between them depends on label directions, the type of construction, and the pest pressure present. Your job as a technician is not to choose the chemistry — the label chooses it for you — but to read, understand, and follow the label exactly.

Reading the Label Before You Touch the Equipment

Federal law (FIFRA) requires that every pesticide be used in accordance with its labeling. The label is a legal document. Before any application, locate and read at minimum:

For soil barrier work, pay particular attention to the volume specified per 10 linear feet of trench, or per 10 linear feet per foot of depth, depending on how the label is written. These numbers are not suggestions; they are the rate that was tested and registered with the EPA.

PPE for Liquid Termiticide Application

The label governs minimum PPE, but standard protective gear for liquid termiticide soil injection includes:

Always don PPE before handling concentrate or filled equipment, not after a spill occurs. If a seal on the sprayer fails or a connection leaks, stop, move away from the spray, and inspect before continuing. Never touch your face, eat, or drink while working with pesticides.

Dilution Math: Concentrate to Finished Product

Label dilution rates are commonly expressed as a percentage (e.g., 0.06% or 0.125% active ingredient in the finished solution) or as a specific volume of concentrate per volume of water. To calculate how much concentrate you need:

1. Determine the total finished volume needed using the label's application rate and the area or linear footage you are treating.

2. Apply the dilution ratio to find the concentrate volume.

3. Subtract concentrate from total finished volume to find how much water to add.

Always add water to the tank first, then add concentrate with the agitator running — this minimizes foaming and exposure.

Equipment Setup and Calibration

A backpack sprayer with a soil injection rod (also called a rod injector or soil rod) is typical for trench and perimeter applications. Before use:

If the sprayer is delivering outside ±10% of the target rate, adjust and re-test. Do not proceed with an uncalibrated sprayer; an under-treated zone will fail, and an over-treated zone may violate the label and cause environmental harm.

Applying the Soil Barrier

For a perimeter soil treatment (post-construction trench-and-treat method, as an example):

Decontamination and Rinse Water Disposal

After application, triple-rinse all equipment. The label will specify how to manage rinse water — typically apply it to a treated area at label rate, not poured down a drain. Remove PPE in the correct order (gloves last), wash hands and face with soap and water, and launder or dispose of contaminated clothing per label instructions. Inspect and store equipment properly to preserve seals and extend service life.

Key Safety Reminders

Key terms9

Repellent termiticideA liquid termiticide that subterranean termites can detect and will avoid, preventing them from crossing the treated soil zone.
Non-repellent termiticideA liquid termiticide that termites cannot detect; they pass through the treated zone and receive a lethal or transferable dose, which can also spread through the colony.
Treated zone (soil barrier)A continuous band of termiticide-treated soil surrounding a foundation that blocks or kills termites attempting to reach the structure.
Dilution rateThe ratio of pesticide concentrate to water or diluent specified on the label to produce the correct finished-product concentration.
Soil injection rodA hollow metal rod attached to a sprayer that delivers liquid termiticide below the soil surface at a controlled depth during trench or sub-slab treatment.
CalibrationThe process of measuring and adjusting a sprayer's output rate to ensure the correct volume of finished product is delivered per unit of area or length.
FIFRAThe Federal Insecticide, Fungicide, and Rodenticide Act — the federal law requiring that pesticides be registered and used only in accordance with their labeling.
Re-entry interval (REI)The minimum time that must pass after a pesticide application before people (or pets) may enter the treated area without the required PPE, as stated on the label.
Trench-and-treatA post-construction soil treatment method in which a trench is dug along the foundation, termiticide is applied to the trench bottom and sides, and the trench is backfilled — sometimes with additional rodding through the fill.

Worked examples4

1. A label specifies applying 4 gallons of finished solution per 10 linear feet of trench. The foundation perimeter of the practice structure is 150 linear feet. How many total gallons of finished solution are needed?
  1. Identify the application rate: 4 gallons per 10 linear feet.
  2. Divide total linear feet by the rate unit: 150 ÷ 10 = 15 units.
  3. Multiply: 15 units × 4 gallons = 60 gallons of finished solution needed.
Answer: 60 gallons of finished solution.
2. The same label calls for a 0.06% finished concentration. The concentrate contains 21.4% active ingredient. How many fluid ounces of concentrate must be added to make 60 gallons of finished solution? (1 gallon = 128 fl oz)
  1. Convert 60 gallons to fluid ounces: 60 × 128 = 7,680 fl oz total finished solution.
  2. Calculate the amount of active ingredient (AI) needed: 7,680 × 0.0006 = 4.608 fl oz of AI.
  3. The concentrate is 21.4% AI, so divide AI needed by the concentrate fraction: 4.608 ÷ 0.214 = 21.53 fl oz of concentrate.
  4. Round to a practical measurement: approximately 21.5 fl oz of concentrate.
Answer: Approximately 21.5 fluid ounces of concentrate added to water to make 60 gallons of finished solution.
3. During calibration, a student collects 32 fluid ounces from the injection rod in exactly 60 seconds at a steady walking pace. The target output is 30 fluid ounces per minute. Is the sprayer within the acceptable ±10% range?
  1. Convert collected volume to a per-minute rate: 32 fl oz collected in 60 seconds = 32 fl oz per minute.
  2. Calculate 10% of the target: 10% × 30 = 3 fl oz.
  3. Determine the acceptable range: 30 − 3 = 27 fl oz/min (low end); 30 + 3 = 33 fl oz/min (high end).
  4. Compare the measured rate (32 fl oz/min) to the range (27–33 fl oz/min): 32 falls within the range.
Answer: Yes, 32 fl oz/min is within the acceptable ±10% range of 27–33 fl oz/min. The sprayer passes calibration.
4. After the application, a student has 2 gallons of termiticide rinse water remaining in the tank. The label says to apply rinse water to a previously treated area at no more than the label application rate. If the label rate is 4 gallons per 10 linear feet, how many linear feet of previously treated trench must receive the rinse water so the rate is not exceeded?
  1. Determine the volume to be disposed: 2 gallons of rinse water.
  2. Identify the label rate: 4 gallons per 10 linear feet.
  3. Set up the proportion: 2 gallons ÷ (4 gallons / 10 linear feet) = 2 × (10/4) = 5 linear feet minimum needed.
  4. Distribute the 2 gallons evenly over at least 5 linear feet of previously treated trench to stay at or below the label rate.
Answer: Spread the 2 gallons of rinse water over at least 5 linear feet of previously treated trench.

The math in this lesson2

Learners scale gallons per 10 linear feet to a 150-foot foundation perimeter.
6.RP.37.RP.3
Brush up in the math halls at newSchoolWorks.com:
In class: Label-reading workshop: instructor distributes the full product labels for two representative non-repellent and repellent liquid termiticides; working in pairs, students read the directions for use section, identify the correct dilution rate for a pre-construction soil treatment, and calculate the volume of concentrate needed to treat a hypothetical 1,500 sq ft foundation perimeter at the label-specified rate, showing all unit-conversion math on a worksheet · Equipment setup and calibration lab: students set up a small (2–3 gallon) backpack or pump sprayer with a soil injection rod, check all seals, measure and mix a water-only training solution to the same volume calculated in the previous activity, and confirm output rate by timing a known volume into a graduated container; any sprayer delivering outside the target range is adjusted and re-tested before students proceed · Simulated soil barrier application: in an outdoor practice area or sandbox trench, each student dons full required PPE (chemical-resistant gloves, safety glasses, long sleeves, closed-toe boots as specified on the label), applies the water training solution to the practice trench at the calculated volume, maintains proper rod depth and rod-spacing technique throughout, and then properly decontaminates equipment and disposes of rinse water according to label instructions; instructor observes and scores with a performance checklist
Materials: Product labels (two representative termiticides, instructor-supplied copies), backpack pump sprayer with soil injection rod, graduated cylinders, gallon jugs for measuring, outdoor sandbox or trench area, water (training solution), chemical-resistant gloves (label-specified), safety glasses, Tyvek coveralls, closed-toe chemical-resistant boots, math worksheet, equipment-calibration log, performance checklist
Check: Students must (1) calculate the correct volume within ±5% error on the math worksheet, (2) achieve a calibrated output rate within ±10% of target, and (3) score 100% on all PPE and label-compliance items on the performance checklist; any deficiency in PPE compliance is an automatic re-do of that portion before the student may continue

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

Pesticide Laws, Regulations, and Safety
1. Under FIFRA, the pesticide label is best described as which of the following?
Pesticide Application Safety and PPE
2. A technician is setting up PPE before mixing a liquid termiticide. The label lists chemical-resistant gloves, safety glasses, and long sleeves as minimum PPE. The employer's policy also requires Tyvek coveralls. Which PPE should the technician wear?
Pest Control Equipment and Application Methods
3. A sprayer calibration test collects 25 fluid ounces in one minute. The target output rate is 30 fluid ounces per minute, and the acceptable tolerance is ±10%. What should the technician do?
Termite and Wood-Destroying Organism Biology and Control
4. Which primary characteristic distinguishes a non-repellent termiticide from a repellent termiticide?
Pesticide Application Safety and PPE
5. When adding a liquid termiticide concentrate to a sprayer tank, what is the correct procedure?
Pesticide Calculations and Calibration
6. A label states the application rate for a pre-construction soil treatment is 4 gallons of finished solution per 10 linear feet. A foundation perimeter measures 200 linear feet. How many gallons of finished solution are required?
Pesticide Laws, Regulations, and Safety
7. After completing a soil termiticide application, the technician has leftover rinse water in the tank. What does the label typically require for disposal of this rinse water?
Termite and Wood-Destroying Organism Biology and Control
8. During a trench-and-treat application, a technician moves the soil injection rod quickly through the trench and finishes in half the expected time. Which problem is most likely to result?
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.