🚧 Under construction — VoTechWorks is being built. A free tech program — complimentary, as our commitment to get America working.
voTechWorksGrade 13 · a vocational technology learning center, by urbanicity
newSchoolWorks.com › VoTechWorks › Agriculture, Environment & Public Service › Agriculture / Horticulture / Landscaping › Greenhouse Production and Environment Management › Lesson 2
AGR-HORT49-05 · Lesson 2 · 12 clock hours · demo

Environmental Controls: Temperature, Humidity, Ventilation, and CO2

Objective. Students explain how temperature differentials (DIF), relative humidity, air circulation, and CO2 concentration influence plant growth rate and quality, and demonstrate how to read and adjust a greenhouse controller to reach an instructor-specified set point.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

Why the Greenhouse Environment Matters

Plants do not grow in isolation. Every process — photosynthesis, transpiration, respiration, cell elongation — responds to the air around the plant. As a greenhouse technician you control four variables that together determine crop quality: temperature (and its day-to-night pattern), relative humidity, air circulation, and carbon dioxide (CO₂) concentration. Learning to read and adjust an environmental controller is the hands-on skill that ties all four together.

Temperature and DIF

Greenhouse growers distinguish between the day temperature (DT) and the night temperature (NT). The difference between them is called the DIF (differential). When DT is higher than NT the DIF is positive; when NT is higher than DT the DIF is negative.

DIF directly affects stem elongation. Under a positive DIF (+10 °F, for example), the plant hormone system promotes internode stretching — internodes are the stem segments between leaves. Under a negative DIF the opposite occurs: internodes remain compact. Commercial growers sometimes use a brief period of cooler temperatures just before and just after sunrise (a "cold pulse") to shorten internodes without chemical growth regulators. The DIF concept applies broadly across bedding plants, potted flowering crops, and vegetable transplants.

For your measurements today: measure internode length with a ruler from the base of one leaf to the base of the next. Average at least five internodes per flat and compare the two DIF treatments.

Relative Humidity and Vapor Pressure Deficit

Relative humidity (RH) expresses how much water vapor the air holds compared to the maximum it could hold at that temperature, reported as a percentage. Air at 80 °F can hold more water vapor than air at 60 °F, so the same absolute amount of moisture produces a lower RH reading in warmer air.

A more precise measure for plant science is vapor pressure deficit (VPD) — the difference between the amount of water vapor in the air and the maximum the air could hold at that temperature. A high VPD means dry air that pulls water out of leaves aggressively, increasing plant stress and wilting risk. A very low VPD means the air is nearly saturated; water does not evaporate from leaf surfaces efficiently, leaves stay wet, and fungal pathogens thrive.

Botrytis cinerea (gray mold) is the pathogen most commonly associated with high-humidity conditions in greenhouses. It sporulates and infects when free moisture sits on plant tissue. Keeping VPD in a moderate range — generally achieved by maintaining RH between roughly 50 and 80 percent depending on crop and temperature — reduces infection risk. Timed ventilation at dusk and dawn, when outside temperatures drop and RH spikes, is a standard cultural practice to exhaust humid air before condensation forms.

Ventilation and Air Circulation

Greenhouse ventilation has two purposes: temperature management and humidity control. Natural ventilation uses roof vents and side walls; mechanical ventilation uses exhaust fans paired with evaporative cooling pads on the opposite wall — the pad-and-fan system. In cold weather, heating and minimal ventilation preserve warmth; in warm weather, fans pull air across the wet pads to cool and dehumidify.

Air circulation fans (horizontal airflow or HAF fans) are different from exhaust fans. They recirculate air inside the greenhouse without exchanging it with outside air. This breaks up stagnant boundary layers around leaves, which strengthens stems, improves gas exchange at the leaf surface, and reduces localized humidity pockets where disease can establish.

CO₂ and Photosynthesis

Outdoor air contains approximately 420 parts per million (ppm) CO₂. Inside a sealed greenhouse during peak daylight hours, plants can deplete CO₂ to levels that limit photosynthesis. Supplemental CO₂ injection — typically raising concentration to 1,000–1,500 ppm — can increase growth rates and yield in tightly managed crops. CO₂ enrichment is most effective when light levels are high; injecting CO₂ on cloudy days or at night has little benefit. When vents are open for cooling, CO₂ enrichment is generally paused because the enriched air escapes immediately.

Reading and Adjusting the Environmental Controller

Modern greenhouse controllers integrate sensors for temperature, humidity, and sometimes CO₂ and light into a single panel or digital interface. Typical adjustable parameters include:

To reach an instructor-specified set point, locate each parameter on the controller, enter the target value, and confirm the change is saved. Always allow 10–15 minutes for the greenhouse environment to stabilize before recording your readings, because temperature and humidity sensors respond to real air conditions, not to the number you entered.

Record your readings every 3 minutes on your data sheet. Your goal is to stay within ±2 °F and ±5% RH of the target range across all monitoring periods.

Safety in the Greenhouse

Key terms10

DIF (Differential)The mathematical difference between day temperature and night temperature in a greenhouse; positive DIF promotes stem elongation, negative DIF suppresses it.
Relative Humidity (RH)The percentage of water vapor in the air relative to the maximum amount the air could hold at that temperature.
Vapor Pressure Deficit (VPD)The difference between the actual water vapor pressure in the air and the saturation vapor pressure; a key indicator of plant transpiration demand and disease risk.
InternodeThe section of plant stem between two successive nodes (leaf attachment points); internode length is a primary indicator of DIF response.
Pad-and-Fan SystemA mechanical ventilation and cooling system that draws outside air through water-saturated evaporative pads, lowering air temperature before it enters the greenhouse.
Horizontal Airflow (HAF) FanA small circulation fan mounted horizontally inside the greenhouse to keep air moving around plants without exchanging it with outside air, reducing humidity pockets and strengthening stems.
CO₂ EnrichmentThe deliberate addition of carbon dioxide to greenhouse air above ambient levels to increase the rate of photosynthesis and plant growth, typically used when vents are closed.
Botrytis cinereaA common fungal pathogen (gray mold) that thrives when relative humidity is high and free moisture sits on plant tissue; managed through ventilation and VPD control.
Heat Set PointThe temperature programmed into the greenhouse controller at which the heating system activates to prevent temperatures from falling below the desired minimum.
Ventilation Set PointThe temperature or humidity level programmed into the controller at which vents, exhaust fans, or the pad-and-fan system are triggered to cool or dehumidify the greenhouse.

Worked examples4

1. Calculate VPD for a greenhouse at 75 °F and 70% RH. The saturation vapor pressure (SVP) at 75 °F is approximately 0.430 psi (use the value provided on your VPD reference chart). Is this VPD favorable or a Botrytis risk?
  1. Step 1 – Find actual vapor pressure: Actual VP = SVP × (RH / 100) = 0.430 × (70 / 100) = 0.430 × 0.70 = 0.301 psi.
  2. Step 2 – Calculate VPD: VPD = SVP − Actual VP = 0.430 − 0.301 = 0.129 psi.
  3. Step 3 – Interpret: A VPD around 0.13 psi (roughly 0.9 kPa) is within a moderate, generally acceptable range for many greenhouse crops. Botrytis risk is elevated when VPD is very low (air nearly saturated); at this value the risk is moderate-low, but the grower should monitor conditions closely as RH approaches 80% or above.
Answer: VPD ≈ 0.129 psi; moderate range, acceptable for most crops with attentive monitoring.
2. Calculate VPD for a greenhouse at 65 °F and 90% RH. The SVP at 65 °F is approximately 0.303 psi. Rank this scenario's Botrytis risk compared to the 75 °F / 70% RH scenario.
  1. Step 1 – Find actual vapor pressure: Actual VP = 0.303 × (90 / 100) = 0.303 × 0.90 = 0.273 psi.
  2. Step 2 – Calculate VPD: VPD = 0.303 − 0.273 = 0.030 psi.
  3. Step 3 – Interpret: A VPD of 0.030 psi is very low; the air is nearly saturated. Free moisture is likely to condense on cool plant tissue. This scenario carries HIGH Botrytis risk and warrants immediate ventilation to exhaust humid air.
Answer: VPD ≈ 0.030 psi; HIGH Botrytis risk — much greater than the 75 °F / 70% RH scenario.
3. You measure five consecutive internodes on a seedling flat grown under positive DIF (+10 °F). Lengths in millimeters are: 18, 20, 17, 21, 19. Calculate the average internode length.
  1. Step 1 – Sum the measurements: 18 + 20 + 17 + 21 + 19 = 95 mm.
  2. Step 2 – Divide by the number of measurements: 95 ÷ 5 = 19 mm.
  3. Step 3 – Record 19 mm as the average internode length for the positive DIF flat. Compare this to the negative DIF flat average to confirm the relationship between DIF sign and elongation.
Answer: Average internode length = 19 mm.
4. The target temperature set point for a pad-and-fan cooling exercise is 72 °F. Your three monitoring readings (at 3, 6, and 9 minutes) are 74 °F, 73 °F, and 71 °F. Are all readings within the ±2 °F tolerance? Which, if any, fall outside?
  1. Step 1 – Determine acceptable range: 72 °F ± 2 °F = 70 °F to 74 °F.
  2. Step 2 – Check each reading: 74 °F — within range (equal to upper limit, acceptable). 73 °F — within range. 71 °F — within range.
  3. Step 3 – Conclusion: All three readings fall within 70–74 °F. All pass the ±2 °F tolerance requirement.
Answer: All three readings are within tolerance; no adjustment to the set point is required.

The math in this lesson1

Learners compute vapor pressure deficit as SVP − SVP × RH/100.
A-SSE.1
Brush up in the math halls at newSchoolWorks.com:
In class: DIF demonstration: instructor shows paired seedling flats grown under positive DIF (+10 °F day/night) vs. negative DIF; students measure internode length, record data in a table, and write a two-sentence explanation of the relationship. · Controller set-point exercise: working in pairs at the greenhouse environmental controller (thermostat/humidity sensor panel or digital controller), students receive a target temperature and humidity range, adjust heat, pad-and-fan, and vent set points, then monitor conditions for 15 minutes and record readings every 3 minutes on a data sheet. · Humidity and disease risk discussion: students calculate vapor pressure deficit (VPD) using a provided chart for three temperature/humidity scenarios and rank each scenario's risk for Botrytis development, citing how to reduce risk through ventilation timing.
Materials: Greenhouse environmental controller, thermometers (dry-bulb and wet-bulb or digital RH sensor), VPD reference chart, data recording sheets, paired DIF demonstration flats, ruler
Check: Students correctly adjust controller set points and record environmental data within ±2 °F and ±5% RH of target for all three monitoring periods; pass mark is accurate readings on all three intervals plus a correct written VPD calculation for one scenario.

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

Greenhouse Crop Production
1. A grower wants to reduce internode elongation in poinsettia cuttings without using a growth-regulating chemical. Which temperature management strategy would best achieve this?
Environmental Control and Plant Science
2. Vapor pressure deficit (VPD) is described as:
Integrated Pest Management / Disease Management
3. Botrytis cinerea (gray mold) is most likely to infect greenhouse crops when:
Greenhouse Mechanization and Environmental Control
4. A greenhouse controller's pad-and-fan set point determines:
Greenhouse Environmental Management
5. During peak daylight in a tightly closed greenhouse, CO₂ levels can fall below ambient. The most practical response is to:
Agricultural Safety and Health
6. Which safety procedure must be followed before replacing a sensor wired into the greenhouse environmental controller panel?
Environmental Control Calculations
7. A greenhouse at 80 °F has a saturation vapor pressure of 0.507 psi. The actual vapor pressure is 0.355 psi. What is the VPD?
Greenhouse Mechanization and Environmental Control
8. Horizontal airflow (HAF) fans differ from pad-and-fan exhaust systems primarily because HAF fans:
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.