newSchoolWorks.com › VoTechWorks › Health & Personal Services › Pharmacy Technician › Compounding: Non-Sterile, Sterile and Hazardous (USP <795>, <797>, <800>) › Lesson 6
HLT-PHAR41-04 · Lesson 6 · 15 clock hours · theory

Cleanroom design and air quality

Objective. Describe ISO-classified areas (ISO 5 primary engineering control, ISO 7 buffer room, ISO 8 anteroom), air pressure and HEPA filtration.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a licensed pharmacist or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

Cleanroom Design and Air Quality

Sterile and hazardous compounding must happen in a controlled environment that limits contamination from particles, microorganisms, and chemical hazards. USP <797> (sterile compounding) and USP <800> (hazardous drugs) set specific engineering and environmental standards. Understanding cleanroom layout and air quality is essential before you ever enter a compounding suite.

The ISO Classification System

The International Organization for Standardization (ISO) classifies cleanrooms by the number of airborne particles allowed per cubic meter at a defined particle size. The lower the ISO number, the cleaner the air.

Think of these zones as a series of nested clean bubbles: the anteroom is cleaner than the general pharmacy, the buffer room is cleaner than the anteroom, and the PEC inside the buffer room is the cleanest point of all.

The Anteroom (ISO 8)

The anteroom serves as an airlock and gowning area. Personnel don personal protective equipment (PPE) here before entering the buffer room. Supplies are often decontaminated or unpacked in the anteroom to reduce particle and contamination loads brought in from outside. For hazardous drug compounding under USP <800>, the anteroom must maintain negative pressure relative to the general pharmacy to keep hazardous vapors from migrating outward.

The Buffer Room (ISO 7)

The buffer room houses the PEC and is where most sterile compounding activity occurs. For non-hazardous sterile compounding, the buffer room is maintained at positive pressure relative to the anteroom so that any air movement flows outward, pushing contaminants away from the clean space. For hazardous sterile compounding, the buffer room is maintained at negative pressure relative to the anteroom, containing any hazardous drug particles or vapors within the room.

USP <797> specifies minimum air changes per hour (ACPH) for buffer rooms to continuously dilute and remove airborne particles. Actual requirements depend on room classification and whether the space is cleanroom-grade or segregated; always follow current USP <797> and your facility's standard operating procedures for the specific number in your setting.

Primary Engineering Controls (ISO 5)

The PEC is the device or workstation that provides the ISO 5 environment where compounding actually occurs. Four main PEC types are used in pharmacy:

1. Laminar Airflow Workbench (LAFW) — Horizontal or vertical laminar flow workbench. HEPA-filtered air flows over the work surface toward the operator. Used for non-hazardous sterile compounding. Never use an LAFW for hazardous drugs because contaminated air blows toward the compounder.

2. Biological Safety Cabinet (BSC) — Draws air inward and exhausts through a HEPA filter, protecting both the product and the operator. Used for hazardous sterile compounding (e.g., chemotherapy).

3. Compounding Aseptic Isolator (CAI) — A closed, glove-box style unit for non-hazardous sterile compounding. Provides ISO 5 air inside an enclosed chamber without requiring a full ISO 7 buffer room in some configurations, subject to USP <797> conditions.

4. Compounding Aseptic Containment Isolator (CACI) — A closed, glove-box style unit for hazardous sterile compounding. Maintains negative pressure inside the isolator to contain hazardous drug vapors and particles.

HEPA Filtration

High-Efficiency Particulate Air (HEPA) filters remove at least 99.97% of airborne particles 0.3 micrometers in diameter or larger. Every PEC and every cleanroom HVAC system uses HEPA filtration to maintain ISO standards. Filters must be certified and tested at installation and on a regular schedule thereafter. A damaged or improperly seated HEPA filter immediately compromises the entire ISO classification of that area.

Air Pressure Relationships

Pressure differentials between zones are critical safety controls. The general rule is:

Pressure gauges (magnehelic gauges or electronic monitors) are installed between zones. Staff must check and document pressure readings at the start of each shift. If pressure falls outside the acceptable range, compounding must stop and the issue must be reported and corrected before work resumes. This is a direct patient and worker safety requirement.

Safety Points

Key terms10

ISO classificationA numbered system rating air cleanliness by allowable airborne particle counts per cubic meter; lower ISO numbers indicate cleaner air.
Primary Engineering Control (PEC)A device such as an LAFW, BSC, CAI, or CACI that provides an ISO 5 environment where sterile compounding is performed.
HEPA filterHigh-Efficiency Particulate Air filter that captures at least 99.97% of particles 0.3 micrometers in diameter or larger, used in PECs and cleanroom HVAC systems.
Buffer roomThe ISO 7-classified room that houses the PEC; maintained at positive pressure for non-hazardous compounding or negative pressure for hazardous drug compounding.
AnteroomThe ISO 8-classified transitional space between the general pharmacy and the buffer room, used for gowning and supply decontamination.
Laminar Airflow Workbench (LAFW)A PEC that directs HEPA-filtered air in a uniform stream across the work surface; used only for non-hazardous sterile compounding.
Biological Safety Cabinet (BSC)A PEC that draws air inward and exhausts it through a HEPA filter, protecting both product and operator; required for hazardous sterile compounding.
Compounding Aseptic Containment Isolator (CACI)A closed, negatively pressurized glove-box PEC used for hazardous sterile compounding to contain drug vapors and particles.
Positive pressureAn air pressure setting in which a room's pressure is higher than adjacent areas, causing air to flow outward and preventing outside contaminants from entering.
Negative pressureAn air pressure setting in which a room's pressure is lower than adjacent areas, drawing air inward so hazardous contaminants cannot escape into surrounding spaces.
In class: Cleanroom floor-plan walk · Pressure and air-change reading · PEC types: LAFW, BSC, CAI, CACI
Materials: Cleanroom diagrams, simulation suite
Check: Quiz ≥ 80%

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

Patient Safety and Quality Assurance
1. Which ISO classification is required for the space inside a primary engineering control where sterile compounding takes place?
Patient Safety and Quality Assurance
2. A buffer room used for non-hazardous sterile compounding should be maintained at what pressure relative to the anteroom?
Patient Safety and Quality Assurance
3. Which primary engineering control is appropriate for preparing an intravenous chemotherapy drug?
Patient Safety and Quality Assurance
4. A pharmacy technician notices the pressure gauge between the anteroom and the hazardous drug buffer room shows equal pressure in both zones. What is the correct action?
Patient Safety and Quality Assurance
5. What is the minimum particle-capture efficiency of a HEPA filter at 0.3 micrometers?
Federal Requirements
6. According to cleanroom zone design, which area is used for gowning and decontaminating supply packages before they enter the sterile compounding room?
Patient Safety and Quality Assurance
7. A technician needs to prepare a non-hazardous sterile IV admixture. Which PEC is the most appropriate choice?
Federal Requirements
8. Which USP chapter primarily governs the environmental and engineering standards for compounding sterile preparations, including ISO classifications and buffer room requirements?