Objective. Use a pharmacy balance, graduates, mortar and pestle, ointment slab and spatula correctly, including geometric dilution.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed pharmacist or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Non-sterile compounding produces preparations that are not required to be sterile—creams, ointments, oral solutions, capsules, and similar dosage forms. USP Chapter <795> sets the standards that govern this work. Accurate use of equipment and sound technique are the foundation of every safe, effective compounded preparation.
Two types of balances are common in non-sterile compounding. The Class A prescription balance is a mechanical torsion balance that can weigh quantities from 120 mg up to 120 g. The electronic analytical balance (often called a digital balance) is now more widely used because it is faster and reads in smaller increments. Both types must be calibrated and zeroed before each use.
Calibration steps for an electronic balance:
1. Place the balance on a level, vibration-free surface.
2. Turn it on and allow it to warm up per the manufacturer's instructions.
3. Use certified calibration weights to verify accuracy. If the display does not match the known weight, adjust according to the manufacturer's procedure and document the calibration.
4. Place weighing paper or a tared container on the pan, then press Tare (or Zero) to subtract its weight before adding ingredients.
Always weigh the minimum weighable quantity or above. For a Class A balance the minimum is 120 mg; weighing less introduces unacceptable error. For electronic balances, follow the manufacturer's stated minimum and the facility's standard operating procedures.
Safety point: Never place chemicals directly on the balance pan—always use weighing paper or a suitable container. Keep the balance clean and covered when not in use.
A graduate is a cylindrical or conical vessel used to measure liquid volumes. Conical graduates are easier to use for larger volumes; cylindrical graduates are more accurate for smaller volumes because the diameter is uniform.
Key rules for liquid measurement:
Safety point: After measuring, verify the correct ingredient and volume before adding it to the preparation. Mislabeled or mis-measured liquids are a leading source of compounding error.
The mortar and pestle is used to grind, triturate (reduce particle size), and blend powders or semisolids. Two types are used in pharmacy:
Proper technique: Use firm, circular strokes with the pestle, working from the center outward. Keep the pestle in contact with the mortar wall to ensure thorough mixing. Scrape down the sides frequently with a spatula.
An ointment slab (also called a pill tile) is a ground-glass or porcelain flat surface used for mixing semisolids such as ointments and creams. It can also be used for levigation (incorporating a powder into a small amount of base or levigating agent to form a smooth paste before adding the bulk base).
A spatula made of stainless steel or hard plastic is used to fold, spread, and blend materials on the slab. Use a firm but controlled back-and-forth and figure-eight motion to achieve uniform mixing. Scrape all material toward the center periodically to avoid waste and to ensure complete blending.
Safety point: Some drug substances can irritate skin or mucous membranes. Wear gloves and, where required by your facility's standard operating procedures, a mask and eye protection when working with powders.
Geometric dilution is a technique for incorporating a small quantity of a potent drug or colorant into a larger quantity of base or diluent to ensure uniform distribution. Skipping this step and simply adding all ingredients together at once can leave the active ingredient unevenly distributed—a patient safety hazard.
How to perform geometric dilution:
1. Place the smaller quantity (the active ingredient or potent substance) in the mortar.
2. Add an approximately equal volume of the diluent or base and mix thoroughly.
3. Add another equal volume of diluent and mix again.
4. Continue doubling the amount added with each step until all the diluent is incorporated.
The result is a preparation where the active ingredient is evenly dispersed throughout the final product. This technique is especially important when the active ingredient makes up a very small percentage of the total weight.
Record every compounding step in the compounding log or batch record: weights, volumes, lot numbers of ingredients, and calibration results. Clean all equipment before and after use. Residue from one preparation can contaminate the next and harm a patient.
Always verify your work with a pharmacist before the preparation leaves the compounding area. The pharmacist performs a final check; the technician's role is to prepare—not to approve the final product.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.