Objective. Students will answer timed, domain-specific practice sets for structure, roofing, electrical, plumbing, HVAC, interiors, and site/grounds at a rate of 75% or better per domain, demonstrating mastery of the technical content most heavily weighted on all three exams.
This lesson, its worked examples and its practice questions has not yet been verified by a credentialed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
All three credentials you are preparing for—InterNACHI CPI, ASHI ACI, and your State Home Inspector License—test the same core technical territory: structure, roofing, electrical, plumbing, HVAC, interiors, and site/grounds. Each exam weights these domains differently, but none ignores any of them. A score of 75% or better in every domain is your target today because that threshold closely reflects the passing standards of the actual credentialing exams and proves you have real competence, not just lucky guessing.
This lesson is about focused repetition. You will move through mini-lectures, timed practice sets, and peer quizzing. Every time you miss a question, that miss is data: it tells you exactly where to re-read the InterNACHI or ASHI Standards of Practice before your next attempt.
The structure domain covers foundations (slab, crawlspace, basement), framing (platform and balloon), load-bearing walls, beams, columns, and connections. Common reportable defects include foundation cracks that are horizontal or stair-step in masonry (serious concern), evidence of settlement or heaving, deteriorated sill plates, notched or bored framing members that compromise structural integrity, and missing or damaged bridging.
Your job is to observe and report, not diagnose or engineer. When a condition exceeds your scope—say, a crack pattern you cannot fully evaluate—the correct language is: recommend evaluation by a licensed structural engineer. Inspectors do not repair, do not guarantee, and do not provide engineering opinions.
Safety note: In crawlspaces, always assess atmospheric hazards before entry. Ensure adequate ventilation. Wear appropriate PPE—knee pads, disposable coveralls, gloves, N95 or better respiratory protection in areas with mold or fiberglass insulation. Apply lockout/tagout protocols if you must isolate any energy source before accessing confined areas.
Key areas: roof covering type and condition, flashing at penetrations and valleys, gutters and downspouts, ventilation, and skylights. Common defects include missing or lifted shingles, improper flashing laps, cracked or absent caulk at penetrations, granule loss on asphalt shingles, and inadequate attic ventilation causing moisture buildup.
Always note your vantage point in your report—walked the roof, viewed from eave, or viewed from ground—because your scope and reliability of findings differ by position. Roofs that are too steep, too wet, or too fragile to walk must be inspected from the safest accessible point.
Inspect the service entrance, main panel, branch circuits, wiring type, outlets, GFCI and AFCI protection, and visible fixtures. Common defects: double-tapped breakers (two conductors under one breaker terminal where not listed for it), missing knockouts, aluminum branch wiring without compatible devices, reversed polarity, missing GFCI protection in kitchens, bathrooms, garages, and exterior locations, and open junction boxes.
Critical safety rule: Inspectors do not remove dead-front covers in a way that creates an arc-flash hazard, and you should never work inside energized panels beyond what your training and SOP authorize. Use a non-contact voltage tester before touching any wire or terminal. PPE includes safety glasses and insulated gloves rated for the voltage level present.
Cover water supply (material, pressure, visible leaks), drain-waste-vent (DWV) system, water heater, fixtures, and fuel gas distribution where visible. Common defects: galvanic corrosion at dissimilar metal joints, improper DWV venting (S-traps), water heater lacking a temperature-pressure relief (TPR) valve with a properly terminated discharge pipe, evidence of active or past leaks, and cross-connections between potable and non-potable water.
Run water at every fixture and observe drainage. Report slow drains and note the age and condition of the water heater, which typically has a service life of eight to twelve years (varies by type and maintenance—never state exact lifespans as guarantees).
Inspect heating and cooling equipment, distribution (ducts or piping), filters, thermostats, and exhaust. Common defects: dirty or missing filters, heat exchangers with visible cracks or corrosion (a serious safety concern—carbon monoxide risk), disconnected or leaking duct sections, absence of combustion air, and condensate drainage problems.
When a heat exchanger crack is suspected, always recommend evaluation by a licensed HVAC technician and flag the carbon monoxide risk prominently in your report. Always operate HVAC equipment through normal controls and report if a system does not respond.
Interiors include walls, ceilings, floors, windows, doors, stairways, railings, and insulation/ventilation in attics. Site and grounds include grading (slope away from foundation), driveways, walkways, retaining walls, vegetation proximity, and drainage.
Key defects: grading that slopes toward the foundation (major moisture intrusion risk), guardrails and stair rails that are loose or missing, windows that do not open or seal properly, and evidence of moisture intrusion at interior surfaces.
After each 25-question timed set, score it immediately and record the number correct in your domain tracker. Any domain below 75% (fewer than 19 of 25 correct) requires a focused 20-minute re-read of the relevant Standards of Practice section before your second attempt. Be honest with your tracker—it is your personal blueprint for exam-day success. Your instructor will review and sign off on all six domains before you advance to the next lesson.
When building flashcards with your group, prioritize: (1) correct terminology (e.g., TPR valve, not pressure valve), (2) inspection sequence within a system, and (3) reportable-vs.-not-reportable distinctions. Exam writers frequently use plausible-sounding distractors that describe conditions an inspector would note but use the wrong terminology or assign the wrong severity. Knowing precise language is as important as knowing the technical content.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.