MFG-INDU16-03 · Lesson 4 · 13 clock hours · theory
Bearing Lubrication: Grease, Oil, and Relubrication Intervals
Objective. Students will select the correct lubricant type and calculate a relubrication interval for a given bearing application using manufacturer specification data and an NLGI grease classification chart.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by a licensed engineer or certified journey-level tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Why Lubrication Matters
Bearings fail most often because of inadequate lubrication — wrong lubricant type, wrong amount, or relubrication that comes too late. A thin film of lubricant separates rolling elements from raceways, carries heat away, and blocks contaminants. Getting that film right is one of the most cost-effective maintenance tasks in any plant or marine facility.
Grease vs. Oil Lubrication Systems
Grease is the most common bearing lubricant. It is a base oil (mineral, synthetic, or biodegradable) thickened with a metallic soap or other agent so it stays where you put it. Grease suits sealed or shielded bearings, moderate speeds, and applications where relubrication access is infrequent.
Oil bath lubrication submerges the lower portion of the bearing in an oil reservoir. It works well for gearboxes, slow-to-moderate speed bearings, and wherever continuous cooling is needed. The oil level should reach the center of the lowest rolling element; overfilling causes churning, heat, and energy loss.
Oil mist systems atomize oil and carry it through piping to bearing housings. They suit high-speed bearings and large numbers of points fed from a central system. Oil mist requires disciplined setup and environmental controls because mist can escape to the atmosphere.
Circulating oil systems pump filtered, cooled oil continuously through the bearing housing. They are used on large, high-load, or high-speed machines where heat removal is critical.
Viscosity
Viscosity is a lubricant's resistance to flow. For bearing oil, viscosity is expressed as ISO Viscosity Grade (ISO VG) — for example, ISO VG 68 has a kinematic viscosity of 68 mm²/s (cSt) at 40 °C. The correct viscosity depends on bearing speed and load: high speed calls for lower viscosity; high load or low speed calls for higher viscosity. Using oil that is too thin starves the film; oil that is too thick increases drag and heat.
For grease, the base oil viscosity inside the thickener must also match the application. A grease labeled NLGI 2 can contain a low or high base oil viscosity — always check the technical data sheet.
NLGI Consistency Grades
The National Lubricating Grease Institute (NLGI) rates grease firmness on a scale from 000 (semi-fluid) to 6 (very hard block grease). Most industrial bearings use NLGI 2, which is smooth, spreadable, and stays in place across a wide temperature range. NLGI 1 is used in cold environments or centralized grease systems where pumpability matters. NLGI 3 is used in high-temperature or vertical-shaft applications where runout is a concern.
| NLGI Grade | Consistency | Typical Use |
|---|---|---|
| 000–00 | Semi-fluid | Enclosed gear cases |
| 0–1 | Very soft | Centralized lube systems, cold climates |
| 2 | Smooth paste | General industrial bearings (most common) |
| 3 | Firm | High temp, vertical shafts |
| 4–6 | Hard to block | Specialty, high-temperature plain bearings |
Base Oil Types
Mineral oil greases are economical and compatible with most seals. They suit general-purpose industrial bearings.
Synthetic base oils (polyalphaolefin, ester, polyalkylene glycol) extend service life, perform at temperature extremes, and reduce friction. They are specified for electric motor bearings operating at high speed, food-processing equipment (with the right additive package), and marine propulsion shaft bearings that must tolerate wide temperature swings.
Biodegradable greases use vegetable-based or synthetic ester base oils. Regulations for many marine environments — especially where grease can contact water — require environmentally acceptable lubricants (EAL). Always verify the vessel's regulatory requirements before substituting lubricants on propeller shaft or stern tube bearings.
Grease Quantity and Housing Fill
Overgreasing is as damaging as undergreasing. Excess grease raises operating temperature, churns, degrades, and can force its way past seals into motors or brakes. A standard guideline is to fill the bearing housing one-third to one-half full for moderate-speed bearings. High-speed applications may call for one-third or less. Follow the equipment manufacturer's specification first; use the general guideline only when no specific value is given.
Relubrication Intervals
Manufacturers publish formulas or tables to estimate how long grease will remain effective. The interval depends primarily on bearing bore diameter, operating speed, operating temperature, and load. A common published approach expresses the interval in operating hours. As a general pattern:
- Larger bore → shorter interval (more surface area, more grease needed)
- Higher speed → shorter interval (grease works harder, oxidizes faster)
- Higher temperature → significantly shorter interval (a sustained temperature rise of roughly 15 °C above the rated base temperature can cut grease life in half)
- Heavy load or shock load → shorter interval
- Contaminated or wet environment → shorter interval
Always use the specific manufacturer's lubrication guide (SKF, Timken, NSK, or equivalent) for the formula applicable to their bearing series. The worksheet in this lesson uses one such published formula approach.
Safety During Lubrication
Lockout/Tagout (LOTO): Before opening a bearing housing to inspect or regrease, follow your facility's energy control program (29 CFR 1910.147). Isolate all energy sources — electrical, pneumatic, hydraulic — and verify zero energy state before touching rotating equipment. The only exception is a purpose-designed running relubrication fitting on a machine that the manufacturer has explicitly designed and labeled for that procedure.
PPE: Wear safety glasses or a face shield when using grease guns under pressure. Grease injection injuries (high-pressure injection through skin) are a medical emergency. Wear chemical-resistant gloves when handling oil or grease for extended periods.
Housekeeping: Wipe excess grease from fittings and housings immediately. Grease on floors creates slip hazards. Dispose of used lubricants according to local regulations; never pour oil into floor drains.
Compatibility: Never mix greases from different thickener families (lithium, calcium, polyurea, etc.) without confirming compatibility — incompatible greases can liquefy and lose all load-carrying ability.
Key terms8
NLGI GradeA numerical scale (000 to 6) established by the National Lubricating Grease Institute that rates the worked consistency (firmness) of grease; NLGI 2 is the most common grade for industrial bearings.
ISO Viscosity Grade (ISO VG)A standardized classification of lubricating oil based on kinematic viscosity at 40 °C, expressed in mm²/s (cSt); for example, ISO VG 68 has a midpoint viscosity of 68 cSt at 40 °C.
Base OilThe fluid component of a grease or oil lubricant that provides the actual lubricating film; may be mineral (petroleum-derived), synthetic (PAO, ester, PAG), or biodegradable.
Relubrication IntervalThe calculated or manufacturer-specified period (usually in operating hours) between grease additions or oil changes for a given bearing under defined operating conditions.
Environmentally Acceptable Lubricant (EAL)A lubricant formulated to be biodegradable and minimally toxic, required by regulation in many marine applications where lubricant may contact navigable waters.
Oil Bath LubricationA method of bearing lubrication in which the lower portion of the bearing is submerged in a static oil reservoir; the oil level should reach the center of the lowest rolling element.
OvergreasingThe condition of applying more grease to a bearing housing than the design allows, causing elevated operating temperature, seal damage, and accelerated lubricant degradation.
Grease CompatibilityThe ability of two greases to be mixed without a significant change in consistency or performance; incompatible greases can liquefy and fail to protect the bearing.
Worked examples4
1. A plant maintenance guide provides the following simplified relubrication interval formula for a grease-lubricated ball bearing under normal load and clean conditions:
Interval (hours) = K × (14,000,000 / (n × √d) − 4 × d)
where n = shaft speed in RPM, d = bearing bore diameter in mm, and K = 1.0 for normal conditions.
Calculate the relubrication interval for a fan motor bearing with a 50 mm bore running at 1,800 RPM under normal load.
- Step 1 — Identify values: d = 50 mm, n = 1,800 RPM, K = 1.0.
- Step 2 — Calculate √d: √50 ≈ 7.071.
- Step 3 — Calculate n × √d: 1,800 × 7.071 = 12,727.8.
- Step 4 — Calculate 14,000,000 ÷ 12,727.8: 14,000,000 ÷ 12,727.8 ≈ 1,099.7.
- Step 5 — Calculate 4 × d: 4 × 50 = 200.
- Step 6 — Subtract: 1,099.7 − 200 = 899.7.
- Step 7 — Multiply by K: 1.0 × 899.7 ≈ 900 hours.
- Step 8 — Interpret: Regrease this bearing approximately every 900 operating hours under normal conditions.
Answer: Relubrication interval ≈ 900 operating hours.
2. Using the same formula and K = 1.0, calculate the relubrication interval for a slow-speed conveyor head-pulley bearing with a 100 mm bore running at 40 RPM.
- Step 1 — Identify values: d = 100 mm, n = 40 RPM, K = 1.0.
- Step 2 — Calculate √d: √100 = 10.
- Step 3 — Calculate n × √d: 40 × 10 = 400.
- Step 4 — Calculate 14,000,000 ÷ 400: 14,000,000 ÷ 400 = 35,000.
- Step 5 — Calculate 4 × d: 4 × 100 = 400.
- Step 6 — Subtract: 35,000 − 400 = 34,600.
- Step 7 — Multiply by K: 1.0 × 34,600 = 34,600 hours.
- Step 8 — Interpret: The calculated interval exceeds practical maintenance cycles; most manufacturers cap the maximum recommended relubrication interval (commonly at 30,000 hours or a fixed calendar period such as 3 years). Follow the manufacturer's cap rather than the raw formula result.
Answer: Raw formula result ≈ 34,600 hours; apply manufacturer's maximum interval cap in practice.
3. A maintenance log shows that a pump bearing (80 mm bore, 960 RPM, K = 1.0) was last greased 1,200 hours ago. Using the formula, determine whether this bearing is overdue for relubrication.
- Step 1 — Identify values: d = 80 mm, n = 960 RPM, K = 1.0.
- Step 2 — Calculate √d: √80 ≈ 8.944.
- Step 3 — Calculate n × √d: 960 × 8.944 = 8,586.2.
- Step 4 — Calculate 14,000,000 ÷ 8,586.2: 14,000,000 ÷ 8,586.2 ≈ 1,630.5.
- Step 5 — Calculate 4 × d: 4 × 80 = 320.
- Step 6 — Subtract: 1,630.5 − 320 = 1,310.5.
- Step 7 — Multiply by K: 1.0 × 1,310.5 ≈ 1,311 hours.
- Step 8 — Compare: 1,200 hours elapsed vs. 1,311-hour interval. The bearing has used 1,200 / 1,311 ≈ 91.5% of its interval and is approaching but has not yet exceeded the relubrication interval. It should be scheduled for relubrication very soon.
Answer: Calculated interval ≈ 1,311 hours; 1,200 hours have elapsed — bearing is not yet overdue but is at approximately 91.5% of its interval and should be lubricated at the next available maintenance window.
4. A maintenance guide states that sustained operating temperature 15 °C above the design base temperature halves the grease service life. A conveyor bearing has a calculated interval of 2,000 hours at 70 °C. The bearing is actually running at 100 °C. What is the adjusted relubrication interval?
- Step 1 — Find the temperature excess above base: 100 °C − 70 °C = 30 °C above the design base.
- Step 2 — Determine how many 15 °C increments: 30 °C ÷ 15 °C per increment = 2 increments.
- Step 3 — Each 15 °C increment halves the interval. After first increment: 2,000 ÷ 2 = 1,000 hours.
- Step 4 — After second increment: 1,000 ÷ 2 = 500 hours.
- Step 5 — Interpret: At 100 °C the relubrication interval drops from 2,000 hours to approximately 500 hours.
Answer: Adjusted relubrication interval ≈ 500 hours.
The math in this lesson2
Learners evaluate a relubrication interval formula from bore size, RPM and condition factor K.
A-SSE.1F-LE.1
In class: Lecture on lubrication fundamentals: viscosity, NLGI consistency grades, base oil types (mineral, synthetic, biodegradable for marine use), and grease vs. oil mist vs. oil bath systems; students complete a fill-in reference card they keep for later labs. · Case study comparison: instructor presents three equipment scenarios (high-speed electric motor, slow-speed conveyor head pulley, marine propeller shaft intermediate bearing) and student groups each research and recommend a lubricant type, grade, and housing fill percentage, then present a three-minute justification. · Relubrication interval calculation exercise using a manufacturer formula approach (based on bearing bore, speed, and load factor from a standard lubrication guide); students calculate intervals for four different machines on a worksheet and identify which machine is overdue based on a maintenance log provided.
Materials: NLGI grease classification chart; bearing manufacturer lubrication guide (SKF or equivalent); lubricant samples (NLGI 2 grease, ISO VG 68 oil, food-grade grease); relubrication calculation worksheet; maintenance log scenario handout.
Check: Worksheet graded: lubricant selection correct for all three scenarios and relubrication interval within ±10% of instructor answer key for at least three of four machines — 75% minimum pass.
Practice check8
Answer each question, then check it. Nothing is recorded; this is your own practice.
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.