Objective. Students terminate coaxial cables with N-type, PL-259 (UHF), F-type, and BNC connectors using the correct tools and technique, achieving measured insertion loss within the connector manufacturer's specified maximum.
This lesson, its worked examples and its practice questions has not yet been verified by an industry-certified professional or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
A coaxial assembly is only as good as its connectors. A poorly terminated connector introduces excess insertion loss, reflects signal power back toward the source, and can fail mechanically in the field. This lab covers the four connector types you will encounter most often in electronics and telecom work: the N-type, PL-259 (UHF), F-type, and BNC.
Coaxial cable carries RF signal on the center conductor and returns it through the outer braid or foil shield. The connector must maintain the same characteristic impedance as the cable — typically 50 Ω or 75 Ω — across the transition from cable to device. Any gap, misalignment, or solder bridge at that transition creates an impedance discontinuity. The result is reflected energy (measured as return loss) and energy absorbed by the connector itself (measured as insertion loss). Manufacturers publish a maximum insertion loss for each connector, and professional installations must meet that figure.
N-type connectors are threaded, weatherproof, and rated for use well into the microwave range. They are common on test equipment, base-station antennas, and outdoor RF runs. N-type connectors are available in 50 Ω and 75 Ω versions; the two are not interchangeable — using the wrong impedance version degrades performance. Most field installations use the crimp style on LMR-240 or similar cable.
PL-259 (UHF) connectors are the large, threaded connectors found on amateur radio equipment, marine VHF radios, and some two-way radio installations. Despite the name "UHF," the design does not maintain controlled impedance and is best suited to frequencies below about 300 MHz. The PL-259 uses a solder-and-screw assembly; the mating socket is the SO-239.
F-type connectors are the standard for cable television, satellite, and over-the-air broadcast distribution. They are inexpensive, small, and available in crimp and compression (push-on) styles. The center conductor of the coaxial cable itself — typically RG-6 — serves as the contact pin, so proper strip length is critical. F-type is a 75 Ω system.
BNC connectors use a quarter-turn bayonet locking mechanism. They are rated to at least 4 GHz on precision versions and are the connector of choice for test-bench work, video (75 Ω), and many 50 Ω instrument connections. Crimp BNC connectors are the most common field type.
Every connector manufacturer publishes a specification sheet that lists exact strip dimensions: how much outer jacket to remove, how much braid to fold back or trim, and how much dielectric to remove to expose the center conductor. Always use the manufacturer instruction sheet for the specific connector and cable combination you are working with. Strip dimensions vary by connector family, cable diameter, and whether the connector is crimp or solder type. Using the wrong dimension is the single most common cause of failed assemblies.
Use a dedicated cable-prep tool for each cable size. These tools are set to the correct strip depths and produce clean, square cuts that hand-stripping with a knife cannot reliably match.
The general sequence for a crimp connector is: (1) slide any required ferrule or crimp ring onto the cable first — this step cannot be undone after the connector body is on; (2) strip the cable to manufacturer dimensions; (3) fold or trim the braid as specified; (4) seat the center conductor fully into the contact; (5) verify the connector body is fully seated before crimping; (6) apply the correct crimp die and compress fully in one stroke. For solder connectors such as the PL-259, the sequence adds a tinning step on the braid, soldering through the solder holes in the barrel, and soldering the center pin — always allowing each joint to cool before handling.
Torque the mating threads to the manufacturer's specified value using a calibrated torque wrench. Hand-tight is not sufficient for RF connectors in service; over-torquing can crack the dielectric.
Soldering station: Keep the iron in its holder when not in use. Solder containing lead requires hand washing after handling; use lead-free solder where required by your instructor. Work in a ventilated area to avoid inhaling flux fumes. Wear safety glasses.
Crimping tools: Keep fingers clear of the crimp die. Inspect tools for cracks before use.
VNA / test equipment: Follow the instrument's power-on and port-connection procedures. Do not exceed the VNA port's maximum input power. Zero (calibrate) the instrument before measuring; an uncalibrated VNA reading is meaningless.
General: Coaxial cable cut ends are sharp. Dispose of cable trim and braid scraps in the designated container to prevent puncture injuries.
Before connecting any assembly to the VNA, perform a continuity check with the coaxial continuity tester: verify the center conductor reads continuous end-to-end and that there is no short between center conductor and shield. A shorted assembly connected to a VNA port can damage the instrument.
Insertion loss is expressed in decibels (dB) as a positive number representing signal lost through the device. A manufacturer might specify a maximum insertion loss of 0.2 dB for an N-type connector at 1 GHz. If your VNA measurement reads 0.15 dB, the assembly passes. If it reads 0.35 dB, the assembly fails and must be remade. Record the measured value, the manufacturer maximum, and a pass/fail notation in your lab log for each of the six assemblies.