Coaxial Cable: Types, Ratings, and Specifications

Objective. Students distinguish among common coaxial cable types (RG-6, RG-11, LMR-240, LMR-400, and 7/8-inch hardline) by impedance, attenuation per unit length, power rating, and appropriate application.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by an industry-certified professional or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

What Is Coaxial Cable?

Coaxial cable ("coax") carries RF signals along a center conductor surrounded by a dielectric insulator, a braided or solid outer conductor (shield), and a protective jacket. Because the signal travels inside the shield, coax rejects external interference and contains the RF field internally. Every coaxial cable has a characteristic impedance — the ratio of voltage to current for a wave traveling along the line under matched conditions. In RF and telecom work, two impedances dominate: 50 Ω (used in two-way radio, cellular, and most RF test equipment) and 75 Ω (used in cable television, broadcast distribution, and satellite systems). Mixing impedances without proper matching creates reflections and signal loss.

Signal Loss in Coaxial Cable

Attenuation is the reduction of signal power as it travels through the cable. It is expressed in decibels per unit length (dB per 100 feet or dB per meter) and increases with frequency. The higher the frequency, the greater the loss per foot. Cable manufacturer datasheets list attenuation at several spot frequencies — for example, at 100 MHz, 400 MHz, and 1000 MHz. You always look up the value at the highest operating frequency to find the worst-case loss.

Total feedline loss = (attenuation per 100 ft) × (run length in feet ÷ 100)

If total feedline loss exceeds the system loss budget, the link will fail.

Common Coaxial Cable Types

RG-6

RG-6 is a 75 Ω cable designed for residential and light-commercial CATV, satellite, and over-the-air antenna wiring. Its outer diameter is roughly 0.270 inches. The dielectric is foam polyethylene, which lowers attenuation compared with solid polyethylene. RG-6 is inexpensive, flexible, and widely available, but its small center conductor limits power-handling capability. Maximum recommended run lengths for CATV are typically up to about 150–200 feet before amplification is needed. It is not used on 50 Ω transmitter outputs.

RG-11

RG-11 is also 75 Ω but uses a larger center conductor and outer diameter (roughly 0.405 inches). Its attenuation is significantly lower than RG-6 at every frequency, making it suitable for longer cable runs in CATV trunk lines and antenna feed runs where signal loss must be minimized. RG-11 is stiffer and more expensive than RG-6. Use it when run length exceeds what RG-6 can support within the loss budget.

LMR-240

LMR-240 (by Times Microwave Systems; "LMR" is a product line designation) is a 50 Ω flexible coaxial cable with an outer diameter of approximately 0.240 inches. The dielectric is foam polyethylene. LMR-240 is a workhorse for short-to-medium antenna cable runs in two-way radio, Wi-Fi, and cellular installations. It is far lower loss than RG-8X or RG-58 and handles moderate power levels. Its flexibility allows routing through conduit and around obstacles.

LMR-400

LMR-400 is a 50 Ω low-loss cable with an outer diameter of approximately 0.405 inches. At 450 MHz, manufacturer data shows roughly 1.5 dB of loss per 100 feet — substantially less than LMR-240 or RG-8. LMR-400 is widely used for base-station antenna feedlines, cellular installations, and commercial two-way radio towers where long runs must keep loss low. It is semi-flexible: it can be bent but requires more effort than smaller cables, and minimum bend radius specifications must be respected to avoid kinking the foam dielectric.

7/8-Inch Hardline (Rigid or Semiflexible)

Hardline uses a solid or corrugated copper outer conductor rather than braid. The 7/8-inch designation refers to the outer-conductor outer diameter. Hardline has extremely low attenuation — typically less than 0.5 dB per 100 feet at VHF/UHF — and high power-handling capability. It is used on broadcast transmitter outputs, large cellular base stations, and high-power repeater sites. Hardline is rigid or semi-rigid; it cannot be bent freely and requires special connectors and weatherproofing at every junction.

Power Ratings

Every cable has a maximum continuous power rating that depends on frequency and ambient temperature. Exceeding this rating overheats the dielectric, causing impedance changes, gas evolution, and eventual failure. Always verify that the transmitter's output power — reduced by any connector losses — is within the cable's rated limit. Hardline and LMR-400 handle kilowatts at lower frequencies; RG-6 is rated for low power only.

Safety Considerations

RF exposure: Energized feedlines radiate at damaged or loose connector points. Never work on a feedline carrying RF power without first confirming the transmitter is off and locked out. Follow your site's lockout/tagout (LOTO) procedure.

Tower and roof work: Installing hardline or long runs of LMR-400 on towers requires proper fall-protection PPE — harness, lanyard, and anchor — in compliance with applicable OSHA regulations. Never carry large reels of heavy coax up a structure without mechanical assistance.

Sharp braid edges: Cut coax ends have sharp wire ends that can puncture skin. Wear gloves when handling cut ends and dispose of braid trimmings safely.

Weatherproofing: Outdoor connectors that are not properly weatherproofed allow moisture ingress that degrades the dielectric, raises attenuation, and can cause arcing at high power. Use self-amalgamating tape or the weatherproofing method specified by the manufacturer.

Selecting the Right Cable

To choose a cable, gather four pieces of information: (1) system impedance (50 Ω or 75 Ω), (2) highest operating frequency, (3) run length, and (4) maximum allowable feedline loss from the system link budget. Look up attenuation per 100 feet from the manufacturer's datasheet at the target frequency. Multiply by run length to get total loss. If it exceeds the budget, select a lower-loss cable and recalculate. Also confirm the power rating meets the transmitter output.

Key terms8

Characteristic ImpedanceThe fixed ratio of voltage to current for a traveling wave on a transmission line, expressed in ohms (commonly 50 Ω or 75 Ω); mismatches cause signal reflections and loss.
AttenuationThe reduction of signal power as it travels through a cable, expressed in decibels per unit length (dB/100 ft); increases with frequency.
Loss Budget (System Budget)The maximum total signal loss a system can tolerate end-to-end and still meet performance requirements; feedline loss must not exceed this figure.
DielectricThe insulating material between a coaxial cable's center conductor and outer shield; its properties determine attenuation, velocity factor, and power rating.
HardlineCoaxial cable that uses a solid or corrugated copper outer conductor instead of braid; provides very low attenuation and high power handling but is rigid and requires special connectors.
Velocity FactorThe ratio of signal speed in a cable to the speed of light in a vacuum; determined by the dielectric material and affects electrical length calculations.
Power RatingThe maximum continuous RF power a cable can carry at a given frequency without overheating the dielectric or damaging the cable structure.
Bend RadiusThe minimum radius to which a cable may be bent without damaging the dielectric or kinking the outer conductor; specified by the manufacturer and especially critical for LMR-400 and hardline.

Worked examples4

1. A technician has an LMR-400 feedline run of 175 feet connecting a two-way radio base station to an antenna. The manufacturer datasheet lists LMR-400 attenuation as 1.5 dB per 100 feet at 450 MHz. The system loss budget allows a maximum of 3.0 dB of feedline loss. Does this run pass or fail the loss budget?
  1. Step 1 – Identify the given values: attenuation = 1.5 dB/100 ft at 450 MHz; run length = 175 ft; loss budget = 3.0 dB.
  2. Step 2 – Calculate total feedline loss: Total loss = (1.5 dB/100 ft) × (175 ft ÷ 100) = 1.5 × 1.75 = 2.625 dB.
  3. Step 3 – Compare to budget: 2.625 dB < 3.0 dB, so the run is within budget.
Answer: Total feedline loss = 2.625 dB. The run PASSES the 3.0 dB loss budget with 0.375 dB of margin.
2. A CATV installer needs to feed a subscriber outlet 220 feet from the tap. RG-6 attenuation at 700 MHz is listed as 6.0 dB/100 ft. RG-11 attenuation at 700 MHz is listed as 3.2 dB/100 ft. The maximum allowable loss for this run is 12.0 dB. Which cable(s) meet the budget, and what is each cable's total loss?
  1. Step 1 – Calculate RG-6 total loss: (6.0 dB/100 ft) × (220 ÷ 100) = 6.0 × 2.2 = 13.2 dB.
  2. Step 2 – Compare RG-6 to budget: 13.2 dB > 12.0 dB. RG-6 FAILS.
  3. Step 3 – Calculate RG-11 total loss: (3.2 dB/100 ft) × (220 ÷ 100) = 3.2 × 2.2 = 7.04 dB.
  4. Step 4 – Compare RG-11 to budget: 7.04 dB < 12.0 dB. RG-11 PASSES.
Answer: RG-6 produces 13.2 dB of loss (fails). RG-11 produces 7.04 dB of loss (passes). RG-11 is the correct choice for this run.
3. A technician uses LMR-240 on a 90-foot Wi-Fi antenna run at 2.4 GHz. The datasheet lists LMR-240 attenuation as 8.0 dB/100 ft at 2.4 GHz. The system loss budget is 6.0 dB. Does this run pass or fail, and if it fails, what is the excess loss?
  1. Step 1 – Identify given values: attenuation = 8.0 dB/100 ft; run length = 90 ft; budget = 6.0 dB.
  2. Step 2 – Calculate total feedline loss: (8.0 dB/100 ft) × (90 ÷ 100) = 8.0 × 0.9 = 7.2 dB.
  3. Step 3 – Compare to budget: 7.2 dB > 6.0 dB. The run FAILS.
  4. Step 4 – Calculate excess loss: 7.2 dB − 6.0 dB = 1.2 dB over budget.
Answer: Total loss = 7.2 dB. The run FAILS by 1.2 dB. The technician should shorten the run, use LMR-400, or revise the system design.
4. A technician has a choice between LMR-400 and 7/8-inch hardline for a 300-foot base-station feedline at 150 MHz. LMR-400 attenuation at 150 MHz is 0.8 dB/100 ft; 7/8-inch hardline attenuation at 150 MHz is 0.22 dB/100 ft. The loss budget is 2.5 dB and the transmitter output is 200 W. Both cables are rated above 200 W at 150 MHz. Calculate total loss for each and identify which cables pass.
  1. Step 1 – Calculate LMR-400 total loss: (0.8 dB/100 ft) × (300 ÷ 100) = 0.8 × 3.0 = 2.4 dB.
  2. Step 2 – Compare LMR-400 to budget: 2.4 dB < 2.5 dB. LMR-400 PASSES (barely, with 0.1 dB margin).
  3. Step 3 – Calculate hardline total loss: (0.22 dB/100 ft) × (300 ÷ 100) = 0.22 × 3.0 = 0.66 dB.
  4. Step 4 – Compare hardline to budget: 0.66 dB < 2.5 dB. Hardline PASSES with 1.84 dB of margin.
Answer: LMR-400 total loss = 2.4 dB (passes with minimal margin). Hardline total loss = 0.66 dB (passes comfortably). Both are electrically acceptable; hardline provides far more margin and is preferred for a permanent high-power installation.

The math in this lesson2

Learners scale attenuation rates per 100 ft to 175 ft and 220 ft runs to compare RG-6 and RG-11.
6.RP.3N-Q.1
Brush up in the math halls at newSchoolWorks.com:
In class: Examine physical samples of five cable types side by side; students complete a comparison table recording impedance, outer-diameter, dielectric type, and jacket material from manufacturer datasheets. · Solve four application-selection problems: given frequency, run length, maximum allowable loss, and installation environment, students choose the appropriate cable type and justify the choice in writing. · Calculate total feedline loss for three different cable runs (different cable type and length) at two frequencies each, using manufacturer attenuation tables, and determine whether each run passes or fails a given system loss budget.
Materials: Cable samples (RG-6, RG-11, LMR-240, LMR-400, hardline segment), manufacturer datasheets, attenuation tables, application-selection worksheet
Check: Application-selection worksheet and loss-calculation problems graded; 80% correct (at least 6 of 7 cable-selection and loss problems correct) to pass.

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

ETA CET – RF and Transmission Lines
1. A residential satellite dish installation requires a 130-foot feedline at 75 Ω impedance. Which cable is the most appropriate choice?
ETA FOI/FOT and ETA CET – RF Systems Calculations
2. A technician measures LMR-400 attenuation from a datasheet as 1.5 dB per 100 feet at 450 MHz. What is the total feedline loss for a 250-foot run at 450 MHz?
BICSI Installer – Cabling Infrastructure and Cable Types
3. Which of the following best describes the key structural difference between hardline and flexible coaxial cable such as LMR-400?
ETA CET – RF and Transmission Lines
4. A 200-foot RG-6 run at 700 MHz has an attenuation of 6.0 dB/100 ft. The system loss budget is 10.0 dB. What is the total loss and does the run pass?
ETA CET – Electronics Theory
5. Why does coaxial cable attenuation increase as operating frequency increases?
ETA CET and BICSI – Workplace Safety
6. Before working on an antenna feedline connected to an active transmitter on a rooftop, what is the FIRST safety action a technician must take?
ETA CET – RF Systems Calculations
7. A technician needs to connect a 50 Ω two-way radio base station to a rooftop antenna using a 350-foot run. The system loss budget is 5.0 dB at 460 MHz. LMR-240 has 3.9 dB/100 ft and LMR-400 has 1.5 dB/100 ft at 460 MHz. Which cable meets the budget?
BICSI Installer – Installation Practices and Cable Integrity
8. An outdoor coaxial connector is installed without weatherproofing. Over time, what is the most likely result?
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.