Embalming Equipment: Machines, Instruments, and Preparation Room Setup
Objective. Students will identify every piece of standard embalming equipment by name and function, demonstrate correct assembly and pressure/rate settings on the arterial injection machine, and set up a preparation room to the facility's infection-control standard before any case begins.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Embalming Equipment: Machines, Instruments, and Preparation Room Setup
Before any embalming case begins, the preparator must know every piece of equipment in the room by name, understand its function, and confirm that the space meets the facility's infection-control standard. Competence with equipment is not optional—it protects you, coworkers, and the families you serve, and it is tested on the National Board Examination.
The Arterial Injection Machine
The arterial injection machine (also called an embalming machine or injection machine) pumps embalming solution through the arterial system. It consists of a fluid reservoir, a pump, a pressure gauge, a rate-of-flow control, and connecting tubing. Two settings govern every injection:
- Pressure (measured in pounds per square inch, psi): determines the force pushing solution into the vessels. Pressure must be set to match the condition of the case—a typical starting point is moderate pressure, adjusted upward for difficult distribution and downward for fragile or edematous tissue. Never exceed the pressure recommended by your chemical manufacturer or your instructor for a given condition.
- Rate of flow (measured in ounces per minute): determines how fast solution enters the body. A slower rate allows better diffusion; a faster rate moves solution through quickly when distribution is the priority.
Assembly steps: attach the intake hose to the reservoir, connect the outflow hose to the arterial tube, tighten all fittings, confirm the power switch is off before plugging in, then set pressure and rate to zero before starting. Always prime the line to clear air before connecting to the body.
The Aspirator and Hydroaspirator
The aspirator creates suction to remove gases, liquids, and semi-solid matter from body cavities during cavity embalming. Electric aspirators use a pump motor; the hydroaspirator (also called a water-jet aspirator) attaches to a water faucet and creates suction through the Venturi principle—water flowing through a narrow jet draws surrounding air and fluid with it. Both are used with the trocar. After use, flush the aspirator thoroughly to prevent blockage and cross-contamination.
Trocars and Cavity Work
The trocar is a long, hollow, pointed instrument used to puncture body cavities, aspirate contents, and inject cavity fluid. It connects to the aspirator for removal and to a gravity or pump source for injection. Trocars come in several diameters; select the appropriate size for the case. Handle trocars with extreme caution—the pointed tip is a significant sharps hazard. Never recap or carry a trocar with the point exposed and unguarded.
Arterial Tubes and Drain Tubes
Arterial tubes (also called injection tubes or cannulas) are inserted into the artery to deliver embalming solution. They vary in diameter and length to fit different vessels. Drain tubes (vein tubes or drainage instruments) are inserted into the vein to allow blood and solution to exit the body during injection. Proper placement of both instruments at a raising site—commonly the right common carotid artery and internal jugular vein—is fundamental to good distribution and drainage. After use, all metal tubes must be cleaned and sterilized per facility protocol.
Scalpel Handles and Blades
A scalpel handle accepts disposable blades of varying sizes. The scalpel is used to make incisions for vessel raising and for restorative work. Mount and remove blades only with a hemostat or a blade-removal device—never use bare fingers. Dispose of used blades immediately in a puncture-resistant sharps container.
Aneurysm Needles
The aneurysm needle (also called an aneurysm hook) is a blunt-tipped instrument with a curved or straight hook used to dissect, separate, and elevate blood vessels from surrounding tissue without cutting them. It is an essential instrument for vessel raising and helps reduce accidental nicks to the vessel wall.
Additional Hand Instruments
A complete instrument tray also includes hemostats (locking clamps for vessels and tissue), scissors, forceps, and vessel directors. Each instrument has a specific role; knowing them by name and function is required for the equipment identification checklist.
Preparation Room Setup: Infection-Control Standard
The preparation room must be set up before the deceased is brought in. Follow this sequence:
1. Don PPE first. Gloves, gown or apron, eye protection, and mask must be in place before handling any instrument or body. This is non-negotiable.
2. Inspect the room. Confirm surfaces are clean and disinfected from any prior case. Check that the floor drain is clear.
3. Position equipment. Place the arterial machine at the head of the table, aspirator within reach of the trocar operator, and instrument tray within arm's reach.
4. Prepare chemical solutions. Mix arterial and cavity chemicals according to manufacturer directions in clearly labeled containers. Never mix chemicals in unlabeled containers.
5. Lay out instruments in logical order. Group scalpels, aneurysm needles, arterial and drain tubes, hemostats, and other instruments so each is accessible in the sequence of use.
6. Confirm sharps disposal. A puncture-resistant sharps container must be open and positioned before any blade is mounted.
7. Verify ventilation. Preparation rooms must maintain adequate airflow per OSHA standards for formaldehyde exposure. Confirm exhaust ventilation is operating.
Safety Summary
- Never operate the injection machine without confirming all connections are secure—a loose fitting under pressure can spray fluid.
- Treat every instrument as potentially contaminated. PPE is required from entry to exit.
- Formaldehyde is a regulated chemical with established exposure limits. Work in a ventilated room, use appropriate PPE, and follow your facility's chemical hygiene plan.
- Report any sharps injury immediately following your facility's exposure-control plan.
Key terms9
Arterial injection machineA pump-driven device that delivers embalming solution through an arterial tube into the vascular system; controlled by pressure (psi) and rate-of-flow (oz/min) settings.
AspiratorA device that creates suction to withdraw gases, liquids, and semi-solid matter from body cavities; may be electric or water-powered (hydroaspirator).
TrocarA long, hollow, pointed instrument connected to the aspirator for cavity aspiration and to a fluid source for cavity injection; a significant sharps hazard requiring careful handling.
Arterial tube (cannula)A hollow metal tube inserted into an artery at a raising site to deliver embalming solution into the vascular system.
Drain tubeA hollow metal tube inserted into a vein to allow blood and spent embalming solution to drain from the body during arterial injection.
Aneurysm needleA blunt-tipped, hooked instrument used to dissect and elevate blood vessels from surrounding tissue without cutting them during vessel raising.
Rate of flowThe speed at which embalming solution enters the body through the arterial machine, typically measured in ounces per minute; adjusted to control diffusion and distribution.
HydroaspiratorA type of aspirator that connects to a water faucet and uses the Venturi principle—fast-moving water through a narrow jet—to generate suction without an electric motor.
PPE (Personal Protective Equipment)Protective gear—including gloves, gown or apron, eye protection, and mask—that must be donned before entering the preparation room or handling any case or instrument.
Worked examples3
1. The instructor specifies a rate of flow of 12 ounces per minute and the case requires approximately 3 gallons of arterial solution. How many minutes will the injection take at that rate?
- Convert gallons to ounces: 3 gallons × 128 oz/gallon = 384 oz.
- Divide total ounces by rate: 384 oz ÷ 12 oz/min = 32 minutes.
Answer: At 12 oz/min, injecting 3 gallons (384 oz) will take 32 minutes.
2. You are mixing a 2-gallon batch of arterial solution. The chemical manufacturer's label calls for 16 oz of concentrated arterial fluid per gallon of water. How many ounces of concentrate do you need for a 2-gallon batch?
- Identify the ratio: 16 oz concentrate per 1 gallon of water.
- Multiply by batch size: 16 oz/gallon × 2 gallons = 32 oz of concentrate.
- Add concentrate to water in a labeled container to make the 2-gallon solution.
Answer: 32 oz of concentrated arterial fluid are needed for a 2-gallon batch at the specified dilution.
3. During an injection at a stated rate of flow, the machine runs for 20 minutes before you stop to assess distribution. How many ounces of solution have been delivered?
- Identify stated rate: 10 oz/min (example rate for this problem).
- Multiply rate by time: 10 oz/min × 20 min = 200 oz.
- Convert to gallons for reference: 200 oz ÷ 128 oz/gallon ≈ 1.56 gallons.
Answer: At 10 oz/min over 20 minutes, approximately 200 oz (about 1.56 gallons) of solution have been delivered.
The math in this lesson2
Learners scale ounces of concentrate per gallon to a 2-gallon batch and multiply rate by time.
6.RP.3N-Q.1
In class: Instructor-led equipment identification tour of the preparation room: each instrument and machine is named, demonstrated, and students complete an equipment identification log with name, function, and care/cleaning requirement. · Arterial machine assembly and calibration demonstration: instructor assembles the machine, explains pressure gauge and rate-of-flow settings, then students take turns assembling and setting the machine to a specified pressure while instructor observes. · Timed preparation-room setup drill: students work individually to lay out all instruments, position the aspirator, prepare chemical solutions, and don PPE within a set time; checklist used for evaluation.
Materials: Arterial injection machine; aspirator/hydroaspirator; trocar set; arterial tubes and drain tubes; scalpel handles and blades; aneurysm needles; preparation room; equipment identification log form
Check: Equipment identification checklist: name and function of all listed instruments, 80% correct; machine assembly observed by instructor, pass/fail (zero unsafe configurations)