Objective. Students measure horizontal and vertical angles to three targets using direct and reverse face readings and compute the mean angle, identifying and correcting for index error.
This lesson, its worked examples and its practice questions has not yet been verified by an industry-certified professional or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
A total station measures horizontal and vertical angles electronically, but no instrument is perfectly manufactured. Small mechanical imperfections—collimation error, trunnion-axis tilt, and vertical index error—introduce systematic bias into every reading. The standard field procedure for eliminating most of these errors is to observe each target in two instrument orientations: face left (the vertical circle is on the observer's left, also called direct) and face right (the vertical circle is on the observer's right, also called reverse). When you average the two readings correctly, the systematic errors cancel mathematically. This is one of the most important habits a survey technician develops, and it is tested on the NSPS CST Level 1–2 exam.
Before taking any angle measurement, the instrument must be centered over the control point and leveled. Use the optical or laser plummet to center the instrument, then level the plate bubble and electronic level display to within the manufacturer's tolerance—typically one division of the plate bubble or a fraction of the displayed tilt value.
Safety first: When working on or near a roadway, parking lot, or any area with vehicle or foot traffic, set up safety cones or barricades before touching the instrument. Wear a high-visibility vest whenever you are within a highway right-of-way. Never leave the tripod unattended where it could be struck; a falling total station causes serious injury and costly damage. When carrying the instrument between setups, always use both hands and keep the instrument secured in its case for any move longer than a few steps.
For horizontal angles, the procedure is:
1. With the instrument in face left, set the horizontal circle to zero (or a convenient initial value) while sighting the reference target (Target 1). Record the reading.
2. Rotate clockwise and sight Target 2; record the horizontal circle reading. Then sight Target 3; record.
3. Plunge (flip) the telescope to put the instrument in face right. Re-sight Target 3 first and record. Then rotate counterclockwise to Target 2 and Target 1, recording each reading.
4. For each target, the face-right reading should differ from the face-left reading by approximately 180°. The mean horizontal angle between two targets is:
Mean = ( Face-Left angle + (Face-Right angle ± 180°) ) ÷ 2
Record every reading in your field book the moment you take it—never reconstruct readings from memory. Use the standard columnar booking format shown in class, with columns for Point, Face, Hz Circle Reading, Zenith Angle, and Remarks.
The total station's vertical circle should read exactly 90° (zenith angle) when the telescope is horizontal, and 0° when pointing straight up. If the instrument has a small index error (also called vertical circle index error or zero error), both face-left and face-right zenith readings are shifted by the same amount in opposite directions, making it detectable.
For a single target:
For a correctly adjusted instrument, Z_L + Z_R = 360°. Any departure from 360° is twice the index error:
Index Error (i) = ( Z_L + Z_R − 360° ) ÷ 2
The corrected mean zenith angle is:
Z_mean = Z_L − i OR equivalently Z_mean = (Z_L + (360° − Z_R)) ÷ 2
A small index error does not make the instrument unusable—the mean of face-left and face-right always removes it. However, if the index error exceeds the manufacturer's published limit (often a few seconds of arc for a construction-grade instrument), the instrument should be recalibrated or returned for service.
After computing your mean horizontal and vertical angles, compare them to the instructor's check values. The allowable discrepancy is two times the instrument's stated angular accuracy. For example, if the total station is rated at 5" (five arc-seconds), your mean angle should agree with the check value within 10". If you consistently exceed this tolerance on all three targets, suspect a systematic error such as:
Random errors that vary from target to target are normal and expected within the tolerance. A bias that shifts all your angles in the same direction suggests a setup or procedural problem.
Your field book is a legal record. Use pencil, make corrections with a single line (never erase), initial any correction, and record the date, weather, instrument serial number, and your name on every page. A well-kept field book is required for the pass criterion of this lab and reflects professional practice expected by every licensed surveyor.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →