Objective. Students will describe and sequence a seven-step fault-isolation process and complete a standard work order for a given fault scenario with no missing required fields.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed engineer or certified journey-level tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
When a robot cell goes down or a conveyor stops unexpectedly, the pressure to restore production is immediate. Without a repeatable method, technicians often jump to the most familiar fix — swapping parts, resetting faults, or guessing — which wastes time, masks the real cause, and can create new hazards. A structured fault-isolation methodology gives you a logical path from symptom to verified repair every time, regardless of the system's complexity. It also produces the documentation that maintenance supervisors, engineers, and auditors depend on.
Step 1 — Observe. Before touching anything, watch and listen. Note indicator lights, alarm codes, sounds, smells, and the state of the machine when the fault occurred. Observe without disturbing the scene. This is also when you confirm that all required lockout/tagout (LOTO) procedures under OSHA 29 CFR 1910.147 are in place before you approach energy-isolated components. Put on required PPE — safety glasses, cut-resistant gloves, arc-rated clothing as needed under NFPA 70E — before getting close to any panel or junction box.
Step 2 — Define the Symptom Precisely. Vague descriptions like "it doesn't work" are not acceptable on a work order or in a root-cause analysis. Write a specific, measurable statement: "Conveyor belt on Line 3 stops within 90 seconds of start-up; motor drive faults with F-007 overcurrent alarm at approximately 8.2 A on phase B." Precise symptom definition narrows the search space immediately.
Step 3 — List Probable Causes. Brainstorm every plausible cause that could produce the defined symptom. Use your knowledge of the system — electrical, mechanical, pneumatic, and control elements. Rank causes from most likely to least likely, considering recent changes, environmental conditions, and maintenance history. For example, an overcurrent fault might be caused by a mechanical jam, a failing motor winding, a worn bearing, an incorrect drive parameter, or a shorted sensor cable. Document all of them before testing any.
Step 4 — Test the Most Likely Cause. Starting with the highest-ranked probable cause, perform a targeted test. Use the correct instrument — a calibrated digital multimeter, clamp-on ammeter, or pressure gauge — and record the actual measurement. Compare it to the specification. A single, focused test either confirms or eliminates a cause. Do not replace parts before you have evidence. If electrical measurements are required on energized circuits, follow NFPA 70E shock and arc-flash boundaries, use appropriate PPE, and obtain an energized-work permit if required by your site policy. Verify absence of voltage at all relevant points before any physical intervention on de-energized circuits.
Step 5 — Repair. Once the root cause is confirmed, make the repair using approved parts, torque specifications, and procedures. Follow ANSI/RIA R15.06 / ISO 10218 safeguarding requirements before re-entering a robot cell. Restore all guards, barriers, and interlocks before re-energizing. Remove lockout/tagout devices only after the area is clear and only the authorized employee who applied each lock removes it, per 29 CFR 1910.147.
Step 6 — Verify. Restart the machine and confirm normal operation through a complete duty cycle, not just a momentary jog. Check that the symptom is gone and that no new faults have appeared. Measure key parameters — motor current, air pressure, cycle time — and compare to baseline specifications. Verification is not complete until the system runs normally under real operating conditions.
Step 7 — Document. Complete the work order fully. Incomplete records are as harmful as no records. Documentation drives predictive maintenance, spare-parts planning, and regulatory compliance.
A work order is a legal and operational record. Required fields typically include:
Downtime calculation is straightforward: subtract the time the equipment was returned to production from the time the fault was first reported. If a fault was reported at 09:15 and the line restarted at 11:40, downtime is 2 hours 25 minutes (145 minutes). Record both the clock times and the total duration.
Modern PLC systems and FANUC robot controllers generate fault codes that are part of your observation in Step 1. A FANUC alarm code appears on the teach pendant with an alarm number and description — always record the full code, not just the alarm number. PLC diagnostic screens in ladder diagram or function block view can show which rung or block is forcing a false condition. These digital clues guide your probable-cause list and save significant troubleshooting time.
A fully completed work order demonstrates that the repair was performed correctly and safely. In industries governed by OSHA, NFPA, and ANSI standards, missing or vague records can expose you and your employer to citations. Good records also show professionalism and are expected by every PMMI Mechatronics and FANUC CERT assessor reviewing your competency portfolio.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →