TRN-MARI24-03 · Lesson 3 · 10 clock hours · lab
Portable Extinguishers and Personal Protective Equipment
Objective. Students will inspect a portable extinguisher using the PASS acronym and P-A-S-S technique, select the correct extinguisher type for an assigned fire class, and don full firefighter PPE including SCBA within the time standard.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by a certified examiner or master technician in the trade or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Why Portable Extinguishers and PPE Matter
Fire is the most dangerous hazard aboard any vessel. The confined spaces, limited escape routes, and flammable cargoes of a ship mean a small fire can become catastrophic within minutes. STCW Basic Training requires every seafarer to demonstrate competence in fire prevention, detection, and suppression — including the correct use of portable extinguishers and personal protective equipment (PPE). This lesson builds the hands-on skills you will be assessed on before you ever step aboard a working vessel.
Fire Classes and Extinguisher Selection
Matching the extinguisher to the fire class is not optional — using the wrong agent can spread the fire or create a new hazard.
- Class A — ordinary combustibles: wood, paper, cloth, rope. Use water or dry chemical ABC.
- Class B — flammable liquids and gases: fuel oil, diesel, gasoline, LPG. Use CO₂, dry chemical BC or ABC, or foam (AFFF).
- Class C — energized electrical equipment. Use CO₂ or dry chemical BC/ABC (non-conductive agents only). Never use water or foam.
- Class D — combustible metals (rare aboard most vessels). Requires a specialized dry-powder agent.
- Class K — cooking oils and fats (galley fires). Use wet chemical agent.
Every extinguisher label lists the fire class it is rated for. Always read the label before selecting an agent.
Portable Extinguisher Inspection (NFPA 10)
NFPA 10 is the standard governing portable fire extinguishers. Monthly visual inspections are required. During a proper inspection you verify:
1. Location and accessibility — extinguisher is in its designated bracket, unobstructed.
2. Pressure gauge — needle is in the green (operable) zone.
3. Pin and tamper seal — pull pin is present; the plastic or wire tamper seal is intact and unbroken.
4. Hydrostatic test date — a tag on the cylinder shows when the last hydrostatic pressure test was performed. NFPA 10 specifies test intervals by extinguisher type; if overdue, the unit must be removed from service.
5. Physical condition — no corrosion, dents, or damaged hose.
6. Weight / fullness — for CO₂, heft the cylinder; a noticeably light unit may be discharged.
Record your findings on the maintenance tag immediately. An incomplete or falsified tag is a safety violation.
The P-A-S-S Technique
When a fire is small and you have a clear escape route behind you, use P-A-S-S:
- P — Pull the pin. This breaks the tamper seal and unlocks the handle.
- A — Aim the nozzle or horn at the base of the flames, not the top.
- S — Squeeze the handle firmly and steadily to discharge the agent.
- S — Sweep side to side across the base of the fire until it is out or the extinguisher is empty.
Maintain the manufacturer's recommended standoff distance — typically 6–10 feet for most portable units, though CO₂ horns require you to stay farther back to avoid frostbite and asphyxiation risk. If the fire does not go out quickly or grows, stop, get out, close the door, activate the alarm, and let the fixed system or fire team handle it. Never turn your back on a fire.
SCBA and Structural Firefighting PPE
Self-Contained Breathing Apparatus (SCBA) protects you from smoke, toxic combustion gases, and oxygen-deficient atmospheres. No firefighting operation in a confined or smoke-filled space should begin without it.
A full structural firefighting ensemble for this lab includes:
- Station wear or equivalent protective clothing
- Structural firefighting gloves
- Helmet
- SCBA with face piece and PASS (Personal Alert Safety System) device
Donning sequence (follow the manufacturer's card for your specific unit):
1. Don station wear and gloves.
2. Place the helmet aside temporarily for face piece fit check.
3. Position the SCBA harness on your back, buckle the waist belt, then the shoulder straps — snug but not cutting off circulation.
4. Open the cylinder valve fully, then back a half-turn.
5. Don the face piece — start with the chin, pull the straps rearward and upward, tighten from the bottom straps first.
6. Perform a positive-pressure seal check: cover the exhalation valve briefly; the face piece should slightly pressurize and you should feel no air leaking at the seal.
7. Breathe normally from the unit for two minutes before entering any hazard area.
8. Activate the PASS device.
The STCW competency standard requires you to complete donning and confirm a positive seal in 3 minutes or less. Practice until donning is automatic — in an actual fire you will be stressed, hot, and possibly disoriented.
Key Safety Rules for This Lab
- Never discharge an extinguisher indoors at the inspection stations — this is an inspection-only rotation.
- At the live-fire prop, wear at minimum your PPE gloves and eye protection; follow all range officer commands immediately.
- CO₂ extinguishers produce extreme cold at the horn — never touch the horn during or after discharge.
- Dry chemical leaves residue that can cause respiratory irritation — work upwind and wash hands after handling.
- If your SCBA low-air alarm sounds during the SCBA rotation, notify the instructor immediately and exit per the instructor's direction.
Key terms10
PASS techniqueThe four-step portable extinguisher operating procedure: Pull the pin, Aim at the base of the fire, Squeeze the handle, Sweep side to side.
Fire classA letter designation (A, B, C, D, or K) that categorizes a fire by the type of fuel involved and determines which extinguishing agents are appropriate.
NFPA 10The National Fire Protection Association standard that governs the selection, installation, inspection, maintenance, and testing of portable fire extinguishers.
Hydrostatic testA pressure test performed on an extinguisher cylinder at specified intervals to verify the cylinder can safely hold its rated pressure; the date is recorded on a tag attached to the unit.
SCBA (Self-Contained Breathing Apparatus)Respiratory protection equipment that supplies the wearer with breathable air from a compressed-air cylinder, used whenever entering smoke-filled or oxygen-deficient spaces.
Positive-pressure seal checkA donning verification step in which the wearer briefly covers the face piece exhalation valve to confirm the unit pressurizes slightly and no air escapes around the seal.
PASS device (Personal Alert Safety System)An alarm worn by a firefighter that emits a loud audible signal if the wearer remains motionless for a set period, alerting rescuers to a firefighter in distress.
Tamper sealA plastic or wire indicator on the pull pin of a portable extinguisher that shows the unit has not been previously discharged or tampered with; an intact seal is required to pass inspection.
Wet chemical agentA Class K extinguishing agent that works by saponification (converting cooking oil to a soapy foam) and cooling, designed specifically for commercial cooking equipment fires.
Structural firefighting ensembleThe combination of protective clothing, gloves, helmet, and SCBA that together provide thermal and respiratory protection during interior firefighting operations.
In class: Lab rotation 1 — extinguisher inspection and selection: students rotate through six stations, each holding a different extinguisher type (water, CO2, dry chemical ABC, dry chemical BC, foam, wet chemical); at each station the student reads the label, checks the hydrostatic test date tag, verifies the pin and seal, checks the pressure gauge, and records findings on a maintenance tag form; instructor checks each completed tag. · Lab rotation 2 — PASS technique live fire: at an outdoor or enclosed burn prop approved for training use, each student applies the P-A-S-S technique (Pull, Aim, Squeeze, Sweep) on a small controlled Class A fire and a small controlled Class B pan fire using the correct extinguisher; instructor scores each discharge on aim, sweep pattern, and distance maintained. · Lab rotation 3 — SCBA donning: each student dons a full firefighter ensemble (station wear or equivalent, structural firefighting gloves, helmet, SCBA with face piece) following the manufacturer's donning sequence; student activates the SCBA, confirms positive pressure seal by covering the exhalation valve, and breathes from the unit for two minutes; instructor records donning time and seal check pass/fail.
Materials: Assortment of portable extinguishers (at least one of each type listed), SCBA units (one per two students), structural firefighting gloves, helmets, PASS device, NFPA 10 inspection reference, manufacturer SCBA donning card, lab log forms, outdoor or enclosed training burn prop
Check: SCBA donning: correctly donned with positive seal confirmed in ≤3 minutes — pass/fail per STCW Basic Training competency table. Extinguisher inspection: at least 5 of 6 station forms correctly completed. PASS discharge: instructor checklist — correct agent selected, aim at base of flame, sweeping motion, proper standoff distance; all four elements required to pass.
Practice check8