Thermal Runaway, HV Emergency Response, and First-Aid Procedures

Objective. Students will describe the stages of lithium-ion thermal runaway, identify warning signs, and demonstrate the correct first-responder actions for an HV vehicle fire or shock victim scenario, consistent with NFPA and OEM emergency response guidance.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a certified examiner or master technician in the trade or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

Why Thermal Runaway Matters

Lithium-ion (Li-ion) battery packs power modern hybrid and battery-electric vehicles. They store enormous amounts of energy in a compact space, which is exactly what makes them useful — and exactly what makes a failure dangerous. When a Li-ion cell loses control of its internal temperature, a chain reaction called thermal runaway can propagate from one cell to the next, releasing toxic gases, intense heat, and fire that can reignite hours or even days after it appears to be out. Every automotive technician working near high-voltage (HV) systems must understand this process and know what to do if it begins.

Stages of Lithium-Ion Thermal Runaway

Thermal runaway does not happen instantly. It moves through recognizable stages, and early recognition gives you the best chance to protect people and property.

Stage 1 — Internal stress and off-gassing. A cell begins to overheat due to a short circuit, overcharge, physical damage, or manufacturing defect. As internal temperature rises, electrolyte begins to break down and the cell vents flammable and toxic gases — most commonly hydrogen, carbon monoxide, and various organic vapors. You may detect a sharp or sweet chemical odor. The battery management system (BMS) may trigger a warning lamp or fault code.

Stage 2 — Venting. Pressure builds inside the cell until the safety vent opens or the casing ruptures. Gas release becomes visible (vapor plume) or audible (hissing). This is a critical decision point: the situation is worsening and evacuation should already be underway.

Stage 3 — First ignition. Vented gases ignite, producing an open flame. Heat from this fire drives neighboring cells into the same failure sequence. Water application on a lithium-ion battery fire is debated in some circles, but fire departments and OEM emergency response guides widely support large volumes of water to cool the pack and surrounding structure. Never attempt to fight a battery fire with a standard dry-chemical extinguisher alone.

Stage 4 — Re-ignition. This is one of the most dangerous characteristics of Li-ion fires. Even after flames appear extinguished, cells deep inside the pack may still be above their thermal stability threshold. Re-ignition can occur minutes, hours, or longer after the initial event. Fire service agencies and OEM emergency response guides (ERGs) stress that vehicles involved in battery fires must be monitored for an extended period and should not be returned to an enclosed structure without confirmed pack temperature stabilization.

Warning Signs to Recognize

If you observe any of these signs, treat the situation as a developing emergency.

First-Responder Actions in the Service Bay

HV warning lamp active (no visible smoke or fire): Stop work immediately. Do not open the battery enclosure. Follow the OEM ERG for that vehicle — most direct you to disable the service disconnect plug using insulated HV gloves (Class 0 minimum, rated for the voltage of the system) and to scan for fault codes before proceeding. Ventilate the bay. Notify your supervisor.

Smoke from the battery compartment: Evacuate all personnel from the bay immediately — do not attempt to diagnose. Activate the facility fire alarm. Call 911. Provide first responders with the vehicle's OEM ERG so they know battery location, voltage level, and recommended approach. Keep bystanders at a safe distance. Do not re-enter until the fire service clears the area.

Electrical shock victim: Do not touch the victim with bare hands if the HV source may still be energized — you will become a second victim. De-energize the source following lockout/tagout (LOTO) procedures if you can do so safely and quickly. If de-energization is not immediately possible, use non-conductive means to separate the victim from the source. Once separated and the scene is safe, call 911, then begin hands-only CPR if the victim is unresponsive and not breathing normally. Use the nearest AED as soon as it is available. Continue until emergency medical services arrive.

Hands-Only CPR and AED Essentials

For an unresponsive adult with no normal breathing:

1. Call 911 (or direct someone else to call).

2. Begin chest compressions — hard and fast, at the center of the chest, at a rate of 100–120 compressions per minute, with a depth of approximately 2–2.4 inches. Allow full chest recoil between compressions.

3. When the AED arrives, power it on and follow the voice prompts — attach pads, stand clear for analysis, deliver shock if advised, then immediately resume compressions.

4. Do not stop unless the victim shows obvious signs of life, a trained provider takes over, or you are physically unable to continue.

PPE and LOTO Reminders

Wear appropriate PPE whenever working near HV systems: Class 0 or higher insulating gloves with leather protectors, safety glasses, and arc-flash-rated face protection where required by the task. Always verify gloves are within their test date and free of damage before use. Follow your facility's LOTO procedure — confirm the HV system is de-energized and locked out before any service that requires opening the HV circuit.

Key Takeaway

The stages of thermal runaway are predictable. Early warning signs give you time to act. Your job as a first responder is not to fight the fire — it is to get people out, call trained help, and provide life-saving assistance to any victim. Know your OEM ERGs, know your facility's emergency plan, and keep your CPR skills current.

Key terms10

Thermal runawayA self-sustaining chain reaction in a lithium-ion cell in which rising temperature causes further heat generation, leading to gas venting, fire, and potential propagation to neighboring cells.
Off-gassingThe release of flammable and toxic gases (such as hydrogen and carbon monoxide) from a lithium-ion cell as its electrolyte begins to decompose under excessive heat or internal stress.
Re-ignitionThe reigniting of a battery fire after it appears extinguished, caused by residual heat in cells deep inside the pack that were not fully cooled.
Battery Management System (BMS)The electronic system that monitors and controls cell voltage, temperature, and state of charge in an HV battery pack, and that triggers warnings when unsafe conditions are detected.
OEM Emergency Response Guide (ERG)A vehicle-specific document published by the manufacturer that provides first responders and technicians with battery location, system voltage, safe approach zones, and recommended actions for emergency situations.
Hands-only CPRA technique for cardiac arrest response that uses continuous chest compressions at 100–120 per minute without rescue breaths, recommended for untrained bystanders or trained responders in adult cardiac arrest.
AED (Automated External Defibrillator)A portable device that analyzes heart rhythm and delivers an electrical shock when needed to restore normal rhythm; designed for use by lay responders through voice and visual prompts.
Lockout/Tagout (LOTO)An OSHA-required procedure for de-energizing and physically locking out equipment — including HV vehicle systems — to prevent accidental re-energization during service.
Class 0 insulating glovesRubber insulating gloves rated and tested for use on electrical systems up to 1,000 V AC, commonly specified as the minimum protection for HV hybrid and EV service work.
Service disconnect plugA manually removable connector in an HV vehicle's battery circuit that interrupts high-voltage current flow, used as a primary de-energization step before HV system service.
In class: Thermal runaway progression lecture and video analysis: students watch OEM and fire-service thermal runaway training footage, then complete a sequencing worksheet placing thermal runaway stages (off-gas, venting, first ignition, re-ignition) in correct order and listing observable indicators of each stage. · Emergency response tabletop simulation: instructor presents three successive scenario cards (1: vehicle on-board HV warning lamp active; 2: smoke from battery compartment in service bay; 3: technician reports tingling from accidental contact with HV component); student teams discuss and present the correct response actions for each, referencing NFPA and OEM emergency response guides. · Hands-only CPR and AED skills station: certified first-aid/CPR instructor (or instructor with current certification) leads students through hands-only CPR technique on a manikin and AED operation on a training AED, with each student completing a full cycle of chest compressions and AED pad placement.
Materials: Projector, OEM Emergency Response Guide (ERG) for training vehicles used in the program, NFPA emergency response for EV reference, scenario cards, CPR training manikins (one per two students), training AED, PPE for CPR practice
Check: Instructor-observed CPR/AED skills check plus written scenario response graded against answer key; CPR compression rate and depth within accepted ranges on instructor observation, scenario responses must include all critical actions. Pass: correct critical actions on all three scenarios, acceptable CPR technique.

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

EV/Hybrid Safety and High-Voltage Systems
1. During a thermal runaway event, which observable sign most reliably indicates that the situation has progressed past Stage 1 (internal stress) and into Stage 2 (venting)?
EV/Hybrid Safety and High-Voltage Systems
2. A technician notices smoke rising from the battery compartment of an EV in the service bay. What is the FIRST action the technician should take?
EV/Hybrid Safety and High-Voltage Systems
3. Why must a vehicle involved in a lithium-ion battery fire be monitored for an extended period even after flames appear extinguished?
EV/Hybrid Safety and High-Voltage Systems
4. A coworker is found unresponsive near an HV component and may still be in contact with an energized source. What should you do BEFORE touching the victim?
EV/Hybrid Safety and High-Voltage Systems
5. When performing hands-only CPR on an adult, which compression rate is consistent with current guidance?
EV/Hybrid Safety and High-Voltage Systems
6. Which document should be provided to arriving fire-service personnel at the scene of an EV battery fire?
EV/Hybrid Safety and High-Voltage Systems
7. Which PPE item is the minimum electrical protection required when handling the HV service disconnect plug on a hybrid or EV?
EV/Hybrid Safety and High-Voltage Systems
8. A thermal runaway event appears to be extinguished in a service bay. The vehicle should NOT be moved back into an enclosed structure until which condition is confirmed?