TRN-AUTO19-08 · Lesson 7 · 18 clock hours · demo
Charging Systems: AC On-Board Charger, DC Fast Charge, and EVSE
Objective. Students will identify Level 1, Level 2, and DC fast-charge connector types and explain the communication handshake and power-conversion process between the EVSE and the vehicle's on-board charging system.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by a certified examiner or master technician in the trade or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Charging Systems: AC On-Board Charger, DC Fast Charge, and EVSE
How EV Charging Works at a System Level
An electric vehicle draws energy from the electrical grid through a piece of infrastructure called the Electric Vehicle Supply Equipment (EVSE). The EVSE does not itself convert power; it safely delivers grid power to the vehicle and manages the communication handshake that authorizes and controls the charge session. Understanding this division of responsibility — EVSE manages safety and signaling, vehicle converts and manages energy — is the foundation of charging system service.
Charging Levels and Connector Standards
Level 1 (AC, ~120 V) uses a standard household outlet and the SAE J1772 connector. Charge rates are slow, typically under 2 kW, making Level 1 suitable for overnight top-up or plug-in hybrid vehicles with small battery packs. The J1772 connector has five pins: two AC power pins (L1 and Neutral), a ground, a Control Pilot (CP), and a Proximity Pilot (PP).
Level 2 (AC, 208–240 V) also uses the SAE J1772 connector in North America, delivering up to roughly 19.2 kW depending on the EVSE rating and the vehicle's on-board charger capacity. The same five-pin J1772 inlet handles Level 1 and Level 2 because the difference is only the supply voltage and circuit ampacity, not the connector.
DC Fast Charge (DCFC) bypasses the on-board charger entirely, delivering high-voltage DC directly to the battery through the vehicle's DC charge port. Three connector standards are in common North American use:
- CCS Combo 1 (CCS1): Combines the upper J1772 AC portion with two large DC pins below it. Uses Power Line Communication (PLC) over the pilot circuit for the charging protocol (ISO 15118 / DIN SPEC 70121).
- CHAdeMO: A separate circular connector with its own inlet; uses a CAN bus-based communication protocol. Common on older Nissan and Mitsubishi vehicles.
- NACS (North American Charging Standard, SAE J3400): Developed by Tesla and released as an open standard; a compact connector handling both AC Level 2 and DC fast charge through the same inlet. Increasingly adopted as an industry standard.
The J1772 Control Pilot Handshake
The Control Pilot (CP) line is a 1 kHz square wave generated by the EVSE at ±12 V. Its duty cycle encodes the maximum current the EVSE can supply, allowing the vehicle to know available power before drawing it. The vehicle's charge inlet circuit places a resistor across CP and ground to signal its state. The IEC 61851-1 standard defines pilot states (often labeled A through F):
- State A: No vehicle connected; CP steady +12 V DC.
- State B: Vehicle connected, not ready; CP oscillates, vehicle pulls to +9 V.
- State C: Vehicle ready, requesting charge; vehicle pulls to +6 V (ventilation not required).
- State D: Charge with ventilation required; vehicle pulls to +3 V.
- State E/F: Fault conditions; EVSE shuts off power.
The duty cycle translates to available current linearly: for duty cycles between 10 % and 85 %, current rating (A) = duty cycle (%) × 0.6. For example, a 25 % duty cycle signals 15 A available.
The On-Board Charger (OBC)
The OBC converts the AC supply from the EVSE into the DC voltage and current required by the high-voltage battery pack. It contains two main functional stages:
1. Power Factor Correction (PFC) stage: Converts AC to an intermediate high-voltage DC bus while drawing current from the grid in a near-sinusoidal waveform, minimizing reactive power. This stage protects the grid supply.
2. Isolated DC-DC converter: Steps the intermediate DC to the exact voltage commanded by the Battery Management System (BMS) and provides galvanic isolation between the AC mains and the HV battery — a critical safety feature.
The BMS monitors cell state-of-charge, temperature, and voltage balance. It sends charge-current and charge-voltage set-points to the OBC via an internal CAN network. The OBC follows these commands, ramping current up during bulk charge and tapering it as the battery approaches full capacity.
Safety Protocols — Non-Negotiable
High-voltage charging circuits carry potentially lethal energy. Observe these rules without exception:
- PPE: Wear Class 0 insulating gloves (rated 1,000 V) tested and in-date, with leather protectors. Use insulated tools rated for the voltage class of the vehicle.
- Lockout/Tagout (LOTO): Before accessing any HV component, remove the manual service disconnect (MSD), apply a lock, and verify absence of voltage with a CAT III or CAT IV meter. Wait for the capacitor discharge interval specified in the OEM service information before touching HV conductors.
- Training vehicle only: Perform all live pilot-signal observations only on designated training vehicles with instructors present. Never probe live HV circuits without authorization and proper metering equipment.
- Orange conductors = HV: On any hybrid or BEV, treat orange-jacketed cables as energized until proven otherwise.
- Shock hazard from EVSE output: Even the EVSE output cable is energized after handshake completion. Follow manufacturer commissioning procedures.
DC Fast Charge: What Changes
During DCFC, the vehicle disables the OBC and opens the DC charge contactors directly to the battery pack. The EVSE (in this context, a DC charging station) contains its own large rectifier. The communication protocol (CCS uses ISO 15118/DIN SPEC 70121 via PLC; CHAdeMO uses CAN; NACS uses its own protocol) negotiates voltage, current limits, and session authentication before the contactors close. The BMS still governs maximum current and voltage; if thermal or voltage limits are reached, it commands the charger station to reduce output. This is why DCFC rates taper as the battery fills and heats up.
Key terms10
EVSE (Electric Vehicle Supply Equipment)Infrastructure hardware that safely delivers grid power to an EV and manages the communication handshake; it does not itself convert power — that is the vehicle's job.
Control Pilot (CP)A 1 kHz square-wave signal generated by the EVSE on a dedicated pin of the J1772 connector; its duty cycle encodes the maximum current available, and the vehicle's resistor states communicate charge readiness back to the EVSE.
SAE J1772The North American standard five-pin AC charging connector used for Level 1 and Level 2 charging, specifying pin layout, pilot signaling, and proximity detection.
CCS Combo 1 (CCS1)Combined Charging System Combo 1; a DC fast-charge connector that adds two large DC pins below the standard J1772 AC inlet and uses Power Line Communication for its charging protocol.
On-Board Charger (OBC)A vehicle-mounted power electronics module that converts AC supply voltage to the DC voltage and current required by the HV battery pack, consisting of a PFC stage and an isolated DC-DC converter stage.
Power Factor Correction (PFC)The first stage of the OBC that converts AC to an intermediate DC bus while shaping the AC current draw to be nearly sinusoidal, reducing reactive power and minimizing grid disturbance.
Pilot StateOne of the defined operating conditions (A through F per IEC 61851-1) communicated between EVSE and vehicle via CP voltage levels, indicating connection status, charge readiness, and fault conditions.
NACS (North American Charging Standard, SAE J3400)A compact EV charging connector standard originally developed by Tesla and released as an open SAE standard; supports both AC Level 2 and DC fast charge through a single inlet design.
Manual Service Disconnect (MSD)A removable high-voltage interlock plug or lever on a hybrid or BEV that physically opens the HV battery circuit to isolate it before service, required as part of lockout/tagout procedures.
Galvanic IsolationAn electrical barrier — provided by the OBC's transformer stage — that prevents direct conductive connection between the AC mains and the HV battery, protecting both the grid and vehicle occupants.
Worked examples4
1. An oscilloscope shows the J1772 Control Pilot signal has a period of 1 ms and is HIGH (+12 V) for 0.25 ms of that period. What is the duty cycle, and what maximum charge current does that signal authorize?
- Calculate duty cycle: Duty cycle (%) = (ON time ÷ Period) × 100 = (0.25 ms ÷ 1.00 ms) × 100 = 25 %.
- Apply the IEC 61851-1 current formula for duty cycles between 10 % and 85 %: Current (A) = Duty cycle (%) × 0.6.
- Current = 25 × 0.6 = 15 A.
Answer: The duty cycle is 25 %, authorizing a maximum charge current of 15 A.
2. A Level 2 EVSE is installed on a 240 V, single-phase circuit and the CP duty cycle reads 50 %. What is the maximum power the EVSE is signaling, assuming unity power factor?
- Find authorized current from duty cycle: Current = 50 % × 0.6 = 30 A.
- Calculate power: Power (W) = Voltage (V) × Current (A) = 240 V × 30 A = 7,200 W.
- Convert to kilowatts: 7,200 W ÷ 1,000 = 7.2 kW.
Answer: The EVSE is signaling a maximum available power of 7.2 kW.
3. A technician needs to set a Level 2 EVSE to authorize 40 A. What duty cycle must the CP signal produce?
- Rearrange the current formula: Duty cycle (%) = Current (A) ÷ 0.6.
- Duty cycle = 40 A ÷ 0.6 = 66.67 %, rounded to 66.7 %.
- Verify it falls in the valid range (10 %–85 %): 66.7 % is within range, so the calculation is valid.
Answer: The CP signal must have a duty cycle of approximately 66.7 % to authorize 40 A.
4. An on-board charger data sheet states it is 92 % efficient. If it draws 7,200 W from a Level 2 EVSE, how many watts reach the HV battery, and how many watts are lost as heat?
- Calculate output power: Output = Input × Efficiency = 7,200 W × 0.92 = 6,624 W.
- Calculate heat loss: Loss = Input − Output = 7,200 W − 6,624 W = 576 W.
Answer: 6,624 W reach the HV battery; 576 W are dissipated as heat in the OBC.
The math in this lesson2
Learners compute J1772 pilot duty cycle, current from duty cycle, and charger losses at 92 percent efficiency.
7.RP.3A-CED.4
In class: Connector identification lab: students examine physical samples of SAE J1772, CCS Combo 1, CHAdeMO, and NACS connectors, completing a comparison chart of pin count, power levels, communication protocol, and typical charge rates for each standard. · EVSE commissioning observation: instructor connects a Level 2 EVSE to a training PHEV or BEV, captures pilot signal waveform on an oscilloscope, and students record the duty-cycle-to-current-rating relationship and the sequence of pilot states (A through F) on a structured data sheet. · On-board charger circuit trace: using OEM wiring diagrams, students trace AC input, PFC stage, isolated DC-DC converter, and output to the battery in a simplified charger schematic, annotating expected voltages and the role of the BMS charge-control signal.
Materials: Physical connector display set (J1772, CCS1, CHAdeMO, NACS), Level 2 EVSE unit, training BEV or PHEV, oscilloscope with pilot-signal probe, OEM charging system service information, connector comparison worksheets
Check: Instructor observation of connector identification accuracy plus completed data sheet; all connector types correctly identified and pilot-signal duty cycle within ±2% of calculated value. Pass: 100% on connector ID, no missing data sheet entries.
Practice check8
Answer each question, then check it. Nothing is recorded; this is your own practice.
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.