Objective. Students will evacuate an automotive HVAC system to the vacuum depth required by the service information and recharge it to the manufacturer-specified weight within ±0.25 oz.
This lesson, its worked examples and its practice questions has not yet been verified by a certified examiner or master technician in the trade or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Evacuation removes air and moisture from the refrigerant circuit before a new charge is installed. Air is a non-condensable gas that raises system pressures and reduces cooling capacity. Moisture reacts with refrigerant and refrigerant oil to form acids that corrode compressor valves, expansion devices, and aluminum components. A proper deep vacuum—measured in microns, not inches of mercury—is the only reliable way to boil off moisture at shop temperature before refrigerant is introduced.
Recharging to the exact weight printed on the underhood label is equally critical. An undercharge starves the evaporator and causes inadequate cooling; an overcharge floods the compressor with liquid refrigerant and can destroy it. The tolerance for this program's lab is ±0.25 oz, which mirrors what professional-grade Recovery, Recycling, and Recharging (RRR) machines can deliver when properly calibrated.
Before connecting any hose to a refrigerant circuit, put on safety glasses and nitrile gloves. Liquid refrigerant contacting skin or eyes causes frostbite. Use only hoses and fittings rated for the refrigerant type on the vehicle's underhood label—R-134a and R-1234yf use different quick-connect service ports to prevent cross-contamination. R-1234yf is mildly flammable (A2L classification); keep open flames and arc-producing tools away from the work area and ensure ventilation.
Always use an EPA Section 608-certified RRR machine. Federal law prohibits venting regulated refrigerants to the atmosphere. The machine recovers refrigerant before you open the system and recycles it before recharge.
Do not stand over the high-side hose connection when attaching it to a charged system—residual pressure can cause a sudden hose whip. Connect the low-side (blue) hose first when the compressor is off.
RRR machine — Recovers, recycles, and recharges refrigerant automatically. An internal digital scale measures charge weight. Many modern machines also pull the evacuation vacuum internally.
Micron gauge (electronic vacuum gauge) — Measures vacuum in microns (µm) of mercury. A standard manifold gauge cannot reliably read below about 500 microns; a micron gauge reads to single-digit microns. Most service information calls for a vacuum of 500 microns or lower before the hold test begins.
Manifold gauge set — Monitors high-side and low-side pressures during operation. High-side is red; low-side is blue.
In-duct thermometer and infrared thermometer — Used after recharge to verify vent outlet temperature meets specification (commonly in the 35–45 °F range at moderate ambient temperatures, but always confirm in service information).
1. Recover any remaining refrigerant using the RRR machine's recovery function. Do not skip this step even if the system appears empty—a micron gauge will confirm.
2. Connect the RRR machine (or vacuum pump and manifold set) to the service ports. Identify A/C service ports by the underhood label and port size/shape.
3. Open both manifold valves and start the vacuum pump or select the evacuation function on the RRR machine.
4. Pull vacuum until the micron gauge reads the specification in the vehicle's service information (frequently 500 microns or lower). Record the reading on your lab form.
5. Hold test: Close the manifold valves, shut off the pump, and observe the micron gauge for the time specified (often 5–10 minutes). If the reading rises rapidly toward atmospheric pressure, a leak exists—find and repair it before proceeding. A slow, slight rise that stabilizes is normal as residual moisture outgasses; re-evacuate if it does not stabilize below 1,000 microns.
6. Record the final hold reading and elapsed time on the lab worksheet.
1. Confirm the refrigerant type and exact weight (oz or g) from the underhood label. Enter these values into the RRR machine.
2. Select the automatic charge function. The machine injects refrigerant by weight from its internal tank. Do not add refrigerant by pressure alone—pressure varies with ambient temperature and is not a reliable measure of charge quantity.
3. When the machine signals charge complete, close the high-side valve first, then the low-side valve. Remove the high-side hose first (compressor off), then the low-side hose. Install service port caps immediately.
4. Start the engine, set the A/C to maximum cooling and high blower speed. Allow system pressures to stabilize (typically 5 minutes).
5. Record high-side and low-side pressures from the machine readout. Compare them to the expected range in the service information at the measured ambient temperature—pressure specifications are temperature-dependent.
6. Insert the in-duct thermometer in the center vent. Record outlet temperature and compare to specification.
High-side pressure above the expected range with a low-side that is also high suggests overcharge or non-condensables. High-side low with low-side low suggests undercharge or a restriction. A vent temperature that is too warm despite correct charge weight may indicate a blend door, blower motor, or refrigerant oil issue—document it and flag for further diagnosis. All readings go on the lab worksheet for instructor grading.
Answer each question, then check it. Nothing is recorded; this is your own practice.