Waveform Capnography, Pulse Oximetry, and Continuous Monitoring
Objective. Students will interpret waveform capnography tracings and pulse oximetry readings to confirm correct airway placement, guide ventilation rate and volume, and recognize early signs of tube dislodgement or patient deterioration.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Why Continuous Monitoring Matters in Airway Management
Once an advanced airway is placed, your job is not finished. Tube dislodgement, bronchospasm, and patient deterioration can occur at any moment during transport. Waveform capnography and pulse oximetry together give you a continuous, real-time picture of oxygenation and ventilation. Used correctly, they are among the most powerful tools in the paramedic's kit. Used without understanding their limitations, they can create false reassurance.
Waveform Capnography: The Basics
Capnography measures the concentration of carbon dioxide (CO₂) in exhaled air and displays it as a waveform over time. The numeric value displayed is the end-tidal CO₂ (EtCO₂), expressed in millimeters of mercury (mmHg). Normal EtCO₂ in a healthy adult at rest is roughly 35–45 mmHg, closely approximating arterial CO₂ levels.
The waveform itself has a recognizable rectangular shape with four phases:
- Phase I: Baseline — exhaled dead-space air with near-zero CO₂
- Phase II: Rapid rise — alveolar gas mixes with dead-space gas
- Phase III: Alveolar plateau — CO₂-rich alveolar gas exhaled; the EtCO₂ reading is taken at the peak of this phase
- Phase IV (descending): Inspiration — CO₂ falls sharply to baseline
A normal waveform has a flat alveolar plateau and returns cleanly to baseline with each breath.
Recognizing Abnormal Waveform Patterns
Absent waveform (flat line): No CO₂ detected. In an intubated patient this strongly suggests esophageal intubation or complete tube obstruction. Treat as misplacement until proven otherwise — immediately confirm tube position clinically and with direct laryngoscopy.
Hyperventilation: Normal waveform shape but EtCO₂ below 35 mmHg. Ventilation rate or tidal volume is too high. Slow the rate and check tidal volume.
Hypoventilation: Normal waveform shape but EtCO₂ above 45 mmHg. Ventilation is inadequate. Increase rate or volume as guided by protocol.
Shark-fin pattern: The alveolar plateau slopes upward rather than remaining flat, creating a pointed peak. This indicates obstructive airflow, most commonly bronchospasm or reactive airway disease. Administer bronchodilator therapy per protocol.
Cardiac arrest waveform: Very low EtCO₂ (often below 10 mmHg) with small, irregular waveforms. EtCO₂ reflects pulmonary perfusion; low values in arrest reflect poor cardiac output. A sudden sustained rise in EtCO₂ during CPR may signal return of spontaneous circulation (ROSC).
Gradually declining EtCO₂: Consider tube displacement (partial), decreasing perfusion, or a leak in the ventilation circuit. Reassess immediately.
Using Capnography to Confirm Tube Placement
Continuous waveform capnography is the gold standard for confirming and monitoring endotracheal tube placement in the prehospital environment. A consistent, rectangular waveform with appropriate EtCO₂ values across multiple breaths confirms the tube is in the trachea. Colorimetric CO₂ detectors change color but do not provide the ongoing monitoring that a waveform device does. Any time the waveform disappears or becomes erratic, treat it as a tube problem until you rule one out.
Pulse Oximetry: Value and Limitations
Pulse oximetry (SpO₂) measures the percentage of hemoglobin saturated with oxygen using light absorption. A reading of 95% or higher is generally considered acceptable in most patients, though clinical context always applies.
SpO₂ is fast and non-invasive, but it has important limitations every paramedic must know:
- Carbon monoxide poisoning: CO binds hemoglobin similarly to oxygen. Pulse oximeters cannot distinguish carboxyhemoglobin from oxyhemoglobin, so the SpO₂ will read falsely high in CO-poisoned patients. These patients may appear well-saturated while being critically hypoxic.
- Peripheral vasoconstriction: Cold extremities, hypoperfusion, or vasoconstrictors reduce the signal. Readings may be unreliable or unobtainable.
- Nail polish and artificial nails: Dark or opaque nail polish can interfere with light transmission. Move the probe to another digit or the earlobe.
- Motion artifact: Patient movement, shivering, or transport vibration can cause falsely low or erratic readings.
- Anemia: Severely anemic patients can have normal SpO₂ readings while carrying inadequate oxygen for tissue needs, because the hemoglobin that is present is fully saturated.
Because of these limitations, SpO₂ must always be interpreted alongside capnography, clinical assessment, and patient history. Never withhold oxygen from a symptomatic patient because SpO₂ appears normal.
Integrating Both Monitors: A Safety Framework
Think of capnography and pulse oximetry as two different windows into the same patient. Capnography tells you about ventilation (CO₂ elimination) and tube position in near-real time — changes appear within a breath or two. Pulse oximetry tells you about oxygenation, but it lags behind ventilation problems by seconds to minutes because of oxygen reserves already in the blood. A patient who loses their airway will show a capnography change before the SpO₂ drops. This lag makes capnography the earlier warning system.
Document EtCO₂ and SpO₂ values at regular intervals on your patient care report. Trending matters: a gradual rise in EtCO₂ or a slow fall in SpO₂ may be more significant than a single abnormal reading.
Safety Priorities
- An absent capnography waveform after intubation is an emergency. Do not assume equipment failure without ruling out esophageal intubation.
- Never adjust ventilation rate or volume based solely on SpO₂.
- In suspected CO poisoning, treat with high-flow oxygen regardless of SpO₂ reading.
- Any unexplained change in waveform or values requires immediate reassessment of the patient and airway.
Key terms8
End-tidal CO₂ (EtCO₂)The concentration of carbon dioxide measured at the end of a patient's exhaled breath, expressed in mmHg; it approximates arterial CO₂ and reflects both ventilation adequacy and pulmonary perfusion.
Waveform capnographyA monitoring method that displays a continuous graphical tracing of exhaled CO₂ over time, allowing assessment of ventilation quality, tube placement, and airway patency breath by breath.
Alveolar plateauPhase III of the capnography waveform; a flat or nearly flat segment representing CO₂-rich alveolar gas being exhaled; normally flat and is where EtCO₂ is measured.
Shark-fin patternAn abnormal capnography waveform in which the alveolar plateau slopes upward to a peak instead of remaining flat, indicating obstructive airflow such as bronchospasm.
Pulse oximetry (SpO₂)A non-invasive measurement of the percentage of hemoglobin in arterial blood saturated with oxygen, obtained by passing light through a perfused tissue bed such as a fingertip.
CarboxyhemoglobinHemoglobin bound to carbon monoxide rather than oxygen; pulse oximeters cannot distinguish it from oxyhemoglobin, causing falsely elevated SpO₂ readings in carbon monoxide poisoning.
Return of spontaneous circulation (ROSC)The resumption of sustained cardiac mechanical activity following cardiac arrest; often signaled during CPR by a sudden, sustained rise in EtCO₂ on the capnography tracing.
Esophageal intubationInadvertent placement of an endotracheal tube into the esophagus rather than the trachea; results in an absent capnography waveform and is immediately life-threatening if not recognized and corrected.
In class: Capnography waveform interpretation lab: students receive 12 printed waveform strips representing normal ventilation, hyperventilation, hypoventilation, esophageal intubation (absent waveform), bronchospasm (shark-fin pattern), and cardiac arrest; students identify each pattern, its clinical significance, and the correct intervention. · Simulation monitoring exercise: using a simulation manikin connected to a capnography training device, students establish an airway, observe the waveform, then respond as the instructor introduces simulated events including tube displacement, bronchospasm, and improving respiratory status; students verbalize and document each intervention. · Pulse oximetry limitations discussion and exercise: students review factors affecting SpO2 reliability (carbon monoxide exposure, peripheral vasoconstriction, nail polish, motion artifact) and apply this knowledge to two written case vignettes where SpO2 data would be misleading without capnography.
Materials: Capnography training device or simulation monitor, printed waveform strip set, simulation manikin, pulse oximetry probes, monitoring competency worksheets, reference guide for waveform interpretation
Check: Students correctly identify all 12 waveform strips and state the correct clinical action for each; pass mark is 10 of 12 correct with no errors on esophageal intubation or cardiac arrest strips.