Objective. Students will transfer laboratory results onto a simulated state drinking water monitoring report and a discharge monitoring report, flag exceedances, and describe the required notification and follow-up actions for each violation scenario.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Every licensed water and wastewater operator has a legal duty to accurately record laboratory results and submit them to the appropriate regulatory authority on time. Falsifying, omitting, or misreporting data is a federal and state crime that can result in license revocation, fines, and criminal prosecution. Accurate reporting also protects public health: a missed exceedance that goes unreported can leave a community drinking unsafe water or expose a waterway to harmful pollutants.
Discharge Monitoring Reports (DMRs) are required under the National Pollutant Discharge Elimination System (NPDES), which is administered by the U.S. Environmental Protection Agency (EPA) and delegated to most state agencies. Wastewater treatment facilities permitted under NPDES must submit DMRs — usually monthly — listing measured effluent values, permit limits, and the number of samples taken for each regulated parameter. Many states now require electronic submission through EPA's NetDMR system.
Drinking Water Monitoring Reports are submitted to the state primacy agency (the state drinking water program authorized to enforce the Safe Drinking Water Act). These reports document sampling results for regulated contaminants such as total coliform, nitrate, disinfection byproducts, and turbidity. The frequency and format vary by system size and contaminant, but the principle is the same: measured values go into designated fields alongside the applicable Maximum Contaminant Level (MCL) or treatment technique trigger.
Follow this sequence every time:
1. Collect and log – Record raw results in the plant laboratory logbook at the time of measurement, including date, time, sample location, method, and analyst initials.
2. Verify units – Confirm that units on the lab result (mg/L, NTU, CFU/100 mL, etc.) match the units required by the permit or rule. A unit mismatch is a common reporting error.
3. Calculate averages or totals – Many permits require both individual sample values and a monthly average. Calculate the average from all valid samples in the reporting period; do not drop outliers without documented justification.
4. Transfer to the form – Enter each value in the correct field. On a DMR, match each parameter to its monitoring location (e.g., Outfall 001) and reporting period.
5. Compare to limits – Write the permit limit next to the measured value if it is not pre-printed. Flag any value that equals or exceeds the limit (for effluent limits) or equals or exceeds the MCL (for drinking water).
6. Sign and certify – The responsible operator or designated official must sign the certification statement, which affirms that the information is true, accurate, and complete to the best of their knowledge. Never sign a form you have not personally reviewed.
An exceedance occurs when a measured value violates a regulatory limit. On a DMR, a daily maximum effluent limit violation means even one sample over the limit is a violation. A monthly average limit violation occurs when the average of all samples in the month exceeds the limit. On a drinking water monitoring report, exceeding an MCL or failing a treatment technique requirement triggers specific follow-up obligations.
Mark each exceedance clearly — many programs require a specific violation code. Circle the value, note the applicable limit, and calculate the magnitude of exceedance so you can communicate it accurately.
Notification timelines vary by contaminant and violation type, but the general framework is:
Water systems serving community customers must produce an annual CCR (also called a water quality report) summarizing the previous year's monitoring results. The CCR must list detected contaminants, their measured levels, the MCL, the likely source, and any violations. Lab result data feed directly from monitoring reports into the CCR. Operators who complete monitoring reports accurately all year make CCR preparation straightforward.
Laboratory work that generates the data you report carries real hazards. Always wear appropriate PPE (gloves, safety glasses, lab coat) when handling samples, reagents, or preserved sample containers. Wastewater samples may contain pathogens — treat all samples as potentially infectious. Chemical preservatives used in sample collection (such as acids for pH preservation) are corrosive; review the Safety Data Sheet (SDS) before use. When working around electrical instrumentation near water, follow your facility's lockout/tagout (LOTO) procedures before performing maintenance on any analytical equipment.
A report submitted on time with one honest error is far better — legally and ethically — than a late report or one where data has been altered. If you discover an error after submission, contact your state agency promptly and submit a corrected report with a clear explanation. Document everything.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.