Objective. Students will load a flat load, accordion load, and minuteman load on an apparatus tailboard and deploy each to a simulated doorway within required distance and without kinks.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
A hose load is not just a way to keep hose tidy on an apparatus. It is a pre-planned deployment system. The way hose is loaded directly controls how fast a crew can stretch a line, whether the line flows without kinks, and how many firefighters are needed to advance it. Choosing the wrong load for a building type or staffing level costs critical seconds and can put crews in a working fire without water. NFPA 1001 Firefighter I standards require competency in multiple load types because conditions vary on every incident.
The flat load is the most basic configuration. Hose is folded back and forth across the bed in flat, parallel folds that lie side by side. Each fold is the full width of the hose bed. The first length is placed with the male coupling at the rear of the bed so it is accessible at the tailboard. Subsequent lengths are connected and folded in alternating directions across the bed.
Strengths: Easy to load, easy to inspect, and easy to reload on the scene. Hose couplings are visible and accessible.
Limitations: Pulling a flat load typically requires at least two firefighters — one to pull the load off the tailboard and one to advance toward the building. It does not self-deploy as efficiently as the minuteman load.
Finish: The working end of the hose (the end that connects to the nozzle) is placed on top, oriented so a firefighter can pull it off first and advance toward the hazard.
In an accordion load, hose folds run lengthwise in the hose bed, stacked on top of one another like the bellows of an accordion. The folds are vertical rather than horizontal. Each successive fold stands upright against the previous one.
Strengths: The accordion load deploys smoothly because the folds peel away cleanly from the bed. It resists tangling and is a common choice for preconnected attack lines because the entire load can be pulled off quickly.
Limitations: Requires careful alignment of folds to prevent bunching. Hose couplings must be kept to the sides of the bed so they do not catch on folds during deployment.
Finish: The nozzle or working end exits the bed last as the load is pulled. Pack the finish so the nozzle operator can grab the top loop and move immediately.
The minuteman load is specifically designed for a single firefighter to pull and advance the entire line without assistance. Hose is loaded so that approximately half the length deploys from the bed as the firefighter pulls, and the remaining half is draped over the firefighter's shoulder in a shouldered carry — the "minuteman" position.
Loading sequence: Start the load at the discharge, running the first section toward the front of the bed, then fold it back. Continue stacking folds. The top portion — the shoulder load — is folded separately and placed on top so it rides on the firefighter's shoulder during advance.
Advance: The firefighter pulls the bottom portion of the load off the bed, places the upper folds on their shoulder, and walks toward the entry point. As they advance, hose pays off the shoulder and off the bed simultaneously, reducing drag and kinking.
Strengths: Designed for understaffed situations or fast initial attack. One firefighter can move the line alone.
Limitations: Requires precise loading to work correctly. If folds are uneven, hose tangles on the shoulder or piles on the ground.
A kink can reduce or stop water flow entirely. Kinks occur when hose makes a sharp bend that collapses the bore. To prevent them:
After deployment to the simulated doorway, the line is charged (water is admitted) by the engineer or by opening the discharge valve. Before charging:
1. Confirm the nozzle is closed.
2. Confirm all personnel are holding the hose.
3. Signal the engineer or call for water.
4. Bleed air from the line through a brief nozzle opening, then close.
5. Announce "charged" and prepare to advance.
Never charge a line with a kink present — the sudden pressure surge can injure the nozzle operator and may rupture the hose.
Hose loads and deployment are tested as Job Performance Requirements (JPRs) under NFPA 1001 Firefighter I. Pro Board and IFSAC certification requires a skills evaluator to observe each critical step on a standardized checklist. A missed critical step — such as deploying a kinked line or failing to fully connect a coupling — is an automatic failure requiring remediation. Practice each load type until the sequence is automatic.