MFG-MECH15-10 · Lesson 4 · 18 clock hours · lab

Full Integrated Mock Certification Exam Day: FANUC CERT, Siemens SMSCP L1, and PMMI Mechatronics

Objective. Under timed, exam-day conditions students will achieve a passing score on a full integrated written mock exam spanning all three credential families and complete a FANUC CERT performance mock without critical errors, then use a scored debrief to finalize their personal exam strategy.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a licensed engineer or certified journey-level tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

What This Day Is For

Today is your full dress rehearsal. You will sit a timed integrated written mock exam covering all three credential families—PMMI Mechatronics, Siemens SMSCP Level 1, and FANUC CERT—under conditions that match the actual exam as closely as possible. You will then complete the full FANUC CERT performance sequence in the robot cell, scored on a NOCTI-style checklist. At the end of the day, you will meet with your instructor for a scored debrief and leave with a signed, written exam strategy plan. There is nothing new to learn today; this is about executing what you already know under pressure and finding any remaining gaps before they cost you on the real exam.

Exam-Day Rules and Conditions

During the written mock, treat the room as an actual testing site. No notes, no phones, no open browser tabs. A basic calculator is permitted. Sit at a single station and do not talk until time is called. The proctor will announce time at the midpoint and again five minutes before the end. When you receive your score sheet by domain immediately after the session, do not compare scores with classmates—use that time to review your own results quietly before the performance portion.

For the performance mock, all standard shop safety rules apply with no exceptions. Before you touch the robot or the cell, don the required PPE: safety glasses and any additional PPE specified by the cell's posted hazard assessment. Before any maintenance or setup step that requires entering the cell or defeating a guard, apply full lockout/tagout per OSHA 29 CFR 1910.147—identify the energy source, isolate it, apply your personal lock, and verify zero energy state. Electrical work inside the panel is governed by NFPA 70E: verify absence of voltage with a properly rated meter before making contact. Machine guarding requirements under OSHA 1910.212 and robot-specific safeguarding under ANSI/RIA R15.06 must be confirmed in place before automatic-mode operation begins. No one enters the robot's restricted envelope while power is on unless the teach pendant is in T1 mode and you hold the enabling device—that is an ANSI/RIA R15.06 requirement and a critical checklist item.

Written Mock: What the Domains Cover

PMMI Mechatronics areas: Fluid Power; Industrial Electricity 1 and 2; Mechanical Components 1 and 2; Motor and Motor Controls; Programmable Logic Controllers 1 and 2. Each area is its own knowledge exam in the real credentialing process, so your mock score sheet will break out each area separately. Know your cylinder-force and hydraulic-speed formulas, 4–20 mA scaling, synchronous speed (Ns = 120f / P), slip, Ohm's law and power, gear and pulley ratios, and the five IEC 61131-3 PLC languages.

Siemens SMSCP Level 1 domains: electrical components; mechanical components and electrical drives; electro-pneumatic and hydraulic control circuits; digital fundamentals and PLCs. Expect questions on series and parallel circuits, drive fundamentals, ladder logic, and pneumatic/hydraulic circuit symbols.

FANUC CERT written domains: HandlingTool Operation and Programming, and ROBOGUIDE offline simulation. Topics include teach pendant jogging, coordinate frames (world, user, tool), I/O configuration, program creation and editing, and system backup procedures.

FANUC Performance Mock: The Full Sequence

You will rotate through the cell one at a time. The instructor scores you; observers score their own checklists to build evaluation skills. Complete these steps in order:

1. Pre-operation safety check — verify guarding, E-stop function, and teach pendant enable switch before energizing.

2. Coordinate-frame jogging — demonstrate jogging in world, joint, and tool frames at T1 speed with the enabling device held correctly.

3. Tool-frame calibration — use the three-point or six-point method to set a tool frame; confirm the TCP is accurate by rotating about the TCP and observing minimal tip movement.

4. Program creation — create a motion program using position registers, motion types (J, L, C), and appropriate speed and termination settings.

5. I/O setup — configure at least one digital output and one digital input in the I/O screen; demonstrate a controlled signal.

6. Automatic-mode run — cycle-start the program in AUTO mode from outside the cell with guarding confirmed; monitor execution.

7. Fault acknowledgment — respond to an instructor-introduced alarm, identify the fault, clear it correctly, and resume.

8. System backup — perform a controller backup to USB media, confirm the files are present, and label the backup.

A single critical error—entering the restricted envelope with power on and no enabling device, bypassing a guard, or skipping lockout before a maintenance step—results in an automatic checklist failure regardless of score on other items.

Scored Debrief and Personal Exam-Strategy Plan

After the performance mock, you meet individually with your instructor. Bring your domain score sheet and your performance checklist. Together you will:

Your instructor will sign the plan if you are cleared to register, or will document a specific remediation assignment with a follow-up date. Instructor sign-off is the final gate before you schedule the actual credentialing exams.

Key terms10

FCR-O1 / FCR-O2FANUC CERT operator-level credentials issued by FANUC America and administered with NOCTI; earned by passing a written exam and a hands-on performance exam covering HandlingTool operation and programming.
FCR-T1 / FCR-T2FANUC CERT technician-level credentials; similar format to operator credentials but covering deeper programming, I/O, and system maintenance tasks.
NOCTI-style performance checklistA structured observation instrument used to score hands-on performance tasks against defined criteria, modeled on the assessment format NOCTI uses in partnership with FANUC America.
Tool-frame calibration (TCP)The process of teaching the robot controller the position and orientation of the tool center point relative to the robot's faceplate, using a multi-point method so the robot can perform accurate tool-tip motion.
ANSI/RIA R15.06 / ISO 10218The U.S. and international safety standards for industrial robots, specifying safeguarding requirements, speed limits in teach mode, restricted envelope control, and collaborative operation guidelines.
IEC 61131-3The international standard defining five PLC programming languages: ladder diagram, function block diagram, structured text, sequential function chart, and instruction list.
SMSCP Level 1Siemens Mechatronic Systems Certification Program Level 1, titled Certified Mechatronic Systems Assistant; covers electrical components, mechanical components and electrical drives, electro-pneumatic and hydraulic control circuits, and digital fundamentals and PLCs.
Lockout/Tagout (LOTO)The hazardous-energy control procedure required by OSHA 29 CFR 1910.147: isolate energy sources, apply personal locks, and verify zero energy state before any servicing that could expose workers to unexpected energization.
4–20 mA analog signalAn industry-standard current loop used to transmit sensor and control signals over distance; 4 mA represents the minimum (0%) process value and 20 mA represents the maximum (100%), allowing wire-break detection at 0 mA.
Synchronous speed (Ns)The theoretical no-load speed of an AC induction motor's rotating magnetic field, calculated as Ns = 120f / P, where f is supply frequency in Hz and P is the number of poles.

Worked examples4

1. A pressure-sensitive analog sensor outputs a 4–20 mA signal scaled to 0–250 PSI. The PLC reads a raw current of 13.2 mA. What pressure does this represent?
  1. Identify the usable current span: 20 mA – 4 mA = 16 mA represents the full 250 PSI span.
  2. Find how far the reading is above the 4 mA baseline: 13.2 mA – 4 mA = 9.2 mA above zero.
  3. Calculate the fraction of full span: 9.2 mA ÷ 16 mA = 0.575 (57.5%).
  4. Apply the fraction to the engineering-unit span: 0.575 × 250 PSI = 143.75 PSI.
Answer: 143.75 PSI
2. An AC induction motor is connected to a 60 Hz supply and has 4 poles. Its nameplate lists full-load speed as 1,746 RPM. Calculate synchronous speed and full-load slip.
  1. Apply Ns = 120f / P: Ns = (120 × 60) / 4 = 7,200 / 4 = 1,800 RPM synchronous speed.
  2. Slip (RPM) = Ns – actual speed = 1,800 – 1,746 = 54 RPM.
  3. Slip as a percentage = (54 / 1,800) × 100 = 3.0%.
Answer: Synchronous speed = 1,800 RPM; full-load slip = 3.0%
3. A pneumatic cylinder has a bore diameter of 2.0 inches and the system supply pressure is 90 PSI. Calculate the theoretical extend force.
  1. Calculate piston area: A = π × r² = π × (1.0 in)² = 3.1416 in².
  2. Apply the force formula: F = P × A = 90 PSI × 3.1416 in² = 282.7 lbf.
Answer: Approximately 283 lbf (rounding to three significant figures)
4. A motor produces 5 horsepower at 1,750 RPM. What is its full-load torque?
  1. Use the torque formula: T = (hp × 5,252) / RPM.
  2. Substitute values: T = (5 × 5,252) / 1,750 = 26,260 / 1,750.
  3. Calculate: T = 15.006 lb·ft, rounded to 15.0 lb·ft.
Answer: 15.0 lb·ft

The math in this lesson3

Learners scale 13.2 mA to pressure on a 0–250 PSI range.
F-LE.1G-MG.2A-CED.4
Brush up in the math halls at newSchoolWorks.com:
In class: Full timed written mock exam administered in a single sitting under examination conditions (no notes, no phones, calculator permitted): the exam consists of questions drawn proportionally from all PMMI Mechatronics test areas, all Siemens SMSCP Level 1 domains, and all FANUC CERT written domains; students are notified of their score by domain immediately after the session so they can see exactly where they stand relative to each credential's passing requirement. · FANUC CERT full performance mock exam: students rotate through the robot cell one at a time and complete the entire FCR performance sequence—pre-operation safety check, coordinate-frame jogging, tool-frame calibration, program creation, I/O setup, automatic-mode run, fault acknowledgment, and system backup—timed and scored by the instructor on the NOCTI-style performance checklist; observers complete their own checklists to build inter-rater reliability and professional evaluation skills. · Scored individual debrief and exam-strategy session: each student meets with the instructor, reviews their written mock results by credential domain and their performance checklist, sets a written personal plan listing any final study tasks and exam-day strategies (time allocation per section, formula recall sequence, performance task order), and receives instructor sign-off confirming readiness or a specific remediation assignment before sitting the actual credentialing exams.
Materials: Integrated written mock exam (instructor-authored, covering all three credential families); FANUC robot cell with full performance setup; NOCTI-style performance checklist; individual score-by-domain feedback sheets; personal exam-strategy planning worksheet; FANUC operator and maintenance manuals for reference during debrief only; PPE; lockout/tagout kit; ROBOGUIDE workstation available for final review if needed
Check: 75% or higher on the integrated written mock exam overall and 75% or higher in each credential family's domain set; zero critical errors on the FANUC CERT performance mock checklist; instructor signs the personal exam-strategy plan confirming the student is cleared to register for the actual exams or documents required remediation steps

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

FANUC CERT — Robot Safety and Standards
1. During the FANUC performance mock, a student needs to enter the robot's restricted envelope to adjust a fixture while the controller is powered on. Which action is required before entering?
FANUC CERT — System Backup and Restore
2. A FANUC controller backup is stored on USB media. Which statement best describes why a backup is a critical performance task?
PMMI Mechatronics — Motor and Motor Controls
3. A 60 Hz, 6-pole AC induction motor runs at 1,160 RPM under full load. What is the motor's slip percentage?
Siemens SMSCP L1 — Electrical Safety / NFPA 70E
4. In NFPA 70E, what must a technician do before touching a conductor that has been de-energized by opening a disconnect switch?
PMMI Mechatronics — Fluid Power
5. A hydraulic cylinder has a 3-inch bore (area ≈ 7.07 in²) and the pump delivers 5 GPM. What is the approximate extension speed of the cylinder rod?
PMMI Mechatronics — Programmable Logic Controllers / Siemens SMSCP L1 — PLCs
6. Which IEC 61131-3 programming language uses graphical networks of function blocks connected by signal lines, making it especially readable for signal-flow applications like PID loops?
FANUC CERT — Frames and Calibration
7. During tool-frame calibration on a FANUC robot, a student sets the TCP and then rotates the robot about the TCP to verify accuracy. What observation confirms a correct calibration?
Siemens SMSCP L1 — Program Overview
8. The Siemens SMSCP Level 1 assessment covers four main domains. Which of the following is NOT one of them?
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.