MFG-MECH15-05 · Lesson 8 · 12 clock hours · demo

DC Motors and DC Drives: Shunt, Series, and Compound Wound

Objective. Students will identify armature and field connections on shunt, series, and compound DC motors, describe how a phase-controlled SCR drive regulates armature voltage to control speed, and apply the power equation P = V × I to calculate drive output.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a licensed engineer or certified journey-level tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

DC Motor Fundamentals

A DC motor converts electrical energy into mechanical rotation by the interaction of magnetic fields. Every DC motor contains two main magnetic circuits: the armature (the rotating part, also called the rotor) and the field (the stationary part, also called the stator). The armature winding sits in slots on the rotor core and connects to external circuits through the commutator — a segmented copper ring — and carbon brushes that slide against it. The commutator keeps current flowing in the correct direction through the armature conductors as the rotor turns, sustaining continuous rotation.

DC motor speed is directly related to the voltage applied to the armature and inversely related to field flux. The basic speed relationship is:

Speed ∝ Armature Voltage / Field Flux

This means you can control speed by raising or lowering armature voltage, by varying field current, or both.

Shunt-Wound DC Motors

In a shunt-wound motor the field winding is connected in parallel (shunt) with the armature across the supply voltage. Because the field receives nearly constant voltage, field flux stays essentially constant under normal load changes. This gives the shunt motor a nearly flat speed-torque curve — speed drops only a few percent from no-load to full-load. Shunt motors are the most common DC machine in industrial service because of this predictable, stable speed regulation. They are well suited to fans, blowers, conveyors, and machine tool spindles.

Series-Wound DC Motors

In a series-wound motor the field winding is connected in series with the armature. All armature current also flows through the field, so field flux varies directly with load. At light loads, current is low, flux is low, and speed climbs steeply — a series motor with no load can reach destructive speeds and must never be operated unloaded. Under heavy load, high current creates high flux, which slows the motor and produces very high torque. The series motor delivers the highest starting torque of any DC type and is used in applications needing large torque bursts: hoists, cranes, and traction drives.

Compound-Wound DC Motors

A compound-wound motor has both a shunt field (in parallel with the armature) and a series field (in series with the armature). The two fields add together in a cumulative compound connection, the most common arrangement. The result is a compromise: better speed regulation than a pure series motor, higher starting torque than a pure shunt motor. Compound motors serve loads with high starting torque requirements where runaway is unacceptable, such as punch presses, elevators, and compressors.

Commutator, Brushes, and Armature Resistance

The commutator and brushes are the principal maintenance items on a DC motor. Worn or glazed brushes increase contact resistance, cause sparking, and reduce efficiency. Armature resistance (R_A) can be measured with the motor de-energized using a digital multimeter (DMM) set to the ohms function. Field resistance is measured the same way across the field terminals. Always follow lockout/tagout procedures (OSHA 29 CFR 1910.147) before making resistance measurements on any machine connected to a power source: isolate the energy source, apply a lock and tag, and verify absence of voltage with the DMM before touching terminals.

SCR Phase-Controlled DC Drives

Modern DC drives regulate armature voltage electronically using silicon-controlled rectifiers (SCRs). An SCR is a thyristor that blocks current until a gate pulse fires it, then conducts for the remainder of that AC half-cycle. By delaying the gate pulse (changing the firing angle), the drive controls how much of each AC half-cycle reaches the armature — effectively varying average DC output voltage from near zero to near full supply voltage. A full-wave SCR bridge typically uses six SCRs (three-phase input) or four SCRs (single-phase input).

Non-regenerative drives can only accelerate and run the motor in one direction; braking is resistive or by coasting. Regenerative drives use a second SCR bridge that allows armature current to reverse direction, returning energy to the AC supply during braking — useful for hoists and precision machine tools.

Most SCR drives also include a separate field power supply. Field weakening (reducing field current) allows the motor to run above base speed at reduced torque, a technique called extended speed range or field weakening control.

Applying P = V × I to Drive Output

The electrical power delivered to the motor armature is:

P = V × I

where P is power in watts, V is armature voltage in volts, and I is armature current in amperes. At nameplate current and rated voltage, this is approximately the motor's input power. Efficiency losses in the armature resistance, brushes, and core are not captured in this simple calculation but it is a reliable first check of drive output.

Safety Points

Key terms8

ArmatureThe rotating winding of a DC motor that carries the main current and produces torque; connected to the external circuit through the commutator and brushes.
CommutatorA segmented copper ring on the DC motor shaft that maintains correct current direction in the armature conductors as the rotor turns.
Shunt fieldA field winding connected in parallel with the armature; receives nearly constant voltage, producing stable flux and near-constant speed under varying load.
Series fieldA field winding connected in series with the armature; flux varies with load current, giving very high starting torque but unstable speed at light loads.
SCR (Silicon-Controlled Rectifier)A thyristor used in DC drives to convert and control AC power to variable DC voltage by adjusting the firing angle of the gate pulse.
Firing angleThe point in the AC cycle at which the SCR gate is triggered; increasing the firing angle reduces average DC output voltage and motor speed.
Field weakeningReducing field current to increase motor speed above base speed; exploits the inverse relationship between speed and field flux.
Regenerative driveA DC drive with a second SCR bridge that allows armature current reversal, returning braking energy to the AC supply instead of dissipating it as heat.

Worked examples4

1. A DC shunt motor nameplate reads: 180 V armature, 10 A full-load armature current. Calculate the electrical power delivered to the armature at full load.
  1. Identify the formula: P = V × I
  2. Substitute values: P = 180 V × 10 A
  3. Calculate: P = 1,800 W
Answer: P = 1,800 W (1.8 kW)
2. A DC drive output is measured at two speed setpoints. At setpoint 1 the armature voltage is 120 V and nameplate current is 10 A. At setpoint 2 the armature voltage is 180 V and nameplate current is 10 A. Calculate drive output power at each setpoint.
  1. Setpoint 1: P₁ = V₁ × I = 120 V × 10 A = 1,200 W
  2. Setpoint 2: P₂ = V₂ × I = 180 V × 10 A = 1,800 W
  3. The difference is 1,800 W − 1,200 W = 600 W additional power at the higher setpoint
Answer: Setpoint 1: 1,200 W; Setpoint 2: 1,800 W
3. A DC shunt motor is running at 1,200 RPM with normal field current. The field current is then weakened by 25% (field flux reduced to 75% of original). Estimate the new approximate no-load speed.
  1. Use the inverse speed-field relationship: Speed ∝ 1 / Field Flux
  2. New flux = 0.75 × original flux
  3. New speed = Original speed × (1 / 0.75) = 1,200 RPM × (1 / 0.75)
  4. New speed = 1,200 × 1.333 = 1,600 RPM
Answer: Approximately 1,600 RPM
4. A student measures armature resistance of a DC motor with a DMM and gets 2.4 Ω. The nameplate lists armature current as 10 A. Calculate the voltage dropped across the armature resistance at full-load current.
  1. Use Ohm's law: V = I × R
  2. V = 10 A × 2.4 Ω
  3. V = 24 V
Answer: 24 V is dropped across the armature resistance at full load

The math in this lesson2

Learners estimate shunt-motor speed change when field flux drops to 75 percent.
6.RP.3A-CED.4
Brush up in the math halls at newSchoolWorks.com:
In class: Instructor demonstration with cut-away DC motor: identify commutator, brushes, armature, shunt field, and series field windings; compare speed-torque characteristics of each type using a graph. · Hands-on: students use a DMM to measure armature resistance and field resistance on a lab DC motor; calculate expected no-load speed change if field current is weakened by 25% using the inverse speed-field relationship. · Instructor shows a DC drive (regenerative or non-regenerative SCR type) on the training panel; students trace the circuit from AC input through SCR bridge to armature output; measure armature voltage at two speed setpoints and verify with P = V × I using nameplate current.
Materials: Cut-away DC motor (fractional or integral hp), DC drive training unit (SCR type), DMM, clamp ammeter, speed-torque curve charts, DC motor nameplate examples, whiteboard
Check: Resistance measurements recorded with correct units; power calculation worksheet graded. Pass = resistance within ±10% of nameplate and power calculation correct; students can orally distinguish shunt vs. series torque behavior.

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

Motor and Motor Controls
1. In a shunt-wound DC motor, the field winding is connected:
Motor and Motor Controls
2. A series-wound DC motor must never be operated without a mechanical load because:
Motor and Motor Controls
3. An SCR phase-controlled DC drive controls motor speed primarily by:
Industrial Electricity
4. A DC motor armature is rated 240 V and 15 A. Using P = V × I, what is the power delivered to the armature at full load?
Motor and Motor Controls
5. Which DC motor type offers the highest starting torque and is commonly used in crane and hoist applications?
Safety
6. Before measuring armature resistance with a DMM on a DC motor connected to a drive, a technician must first:
Motor and Motor Controls
7. A shunt DC motor runs at 900 RPM at normal field current. Field current is reduced so that field flux drops to 60% of its original value. What is the approximate new no-load speed?
Motor and Motor Controls
8. A compound-wound DC motor differs from both shunt and series motors because it:
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.