BLD-WELD01-06 · Lesson 7 · 10 clock hours · theory
Shielding Gas, Filler Metal, and Code Documentation
Objective. Students will explain the effects of argon versus argon/helium shielding gas blends on arc characteristics and heat input, classify filler metals using AWS A5-series designations, and complete a sample Welding Procedure Specification (WPS) record for a GTAW application.
Shielding Gas, Filler Metal, and Code Documentation in GTAW
Why Shielding Gas Matters
In Gas Tungsten Arc Welding (GTAW), the shielding gas does three jobs simultaneously: it protects the molten weld pool and hot tungsten electrode from atmospheric oxygen and nitrogen, it influences the shape and penetration of the arc, and it affects how much heat reaches the base metal. Choosing the wrong gas or flow rate can cause porosity, tungsten contamination, or inadequate fusion — all of which are rejectable defects under structural and pipe codes.
Argon (100% Ar) is the standard shielding gas for most GTAW work. It ionizes easily, which means the arc starts smoothly and remains stable at lower voltages. Argon produces a narrow, focused arc with moderate penetration. Its lower thermal conductivity also means the heat stays concentrated at the arc center, producing a well-defined bead with minimal width. For thin base metals, aluminum, and most stainless steel work, 100% argon is the everyday choice.
Argon-Helium blends (typically 25% to 75% helium) raise arc voltage at the same current because helium has much higher thermal conductivity than argon. The result is a hotter, wider arc that increases travel speed potential and penetration depth. Helium blends are used when welding thick sections, when higher heat input is needed to meet preheat or interpass temperature requirements, or when faster travel speeds are required on production work. The trade-off is that helium is more expensive, the arc is slightly harder to start, and flow rates must be higher (helium is lighter than air and rises, requiring more volume to maintain adequate coverage).
Flow rates for argon typically run in the range of 15–25 cubic feet per hour (CFH) depending on cup size and joint geometry. Helium blends require higher flow rates — often 25–35 CFH or more — to maintain equivalent shielding coverage. Always verify the flow rate called out on the Welding Procedure Specification (WPS) for your job; never guess.
Safety note: Shielding gases are stored in high-pressure cylinders. Secure cylinders upright with a chain or bracket at all times. Use regulators and flowmeters rated for the specific gas. Argon and helium are colorless, odorless, and non-toxic, but both are simple asphyxiants — they displace oxygen in confined spaces. Ensure adequate ventilation. Follow lockout/tagout (LOTO) procedures when changing cylinders on automated equipment.
AWS A5-Series Filler Metal Designations
The American Welding Society publishes the A5-series standards that classify filler metals by chemistry and mechanical properties. Every electrode or filler rod you pick up has an AWS designation on its packaging, and reading that designation tells you exactly what the wire is made of and what it is designed to weld.
The most common A5 standards you will encounter in GTAW:
- AWS A5.18 — Carbon steel filler metals (e.g., ER70S-2, ER70S-6)
- AWS A5.9 — Stainless steel filler metals (e.g., ER308L, ER316L)
- AWS A5.10 — Aluminum and aluminum-alloy filler metals (e.g., ER4043, ER5356)
Reading the designation: Take ER70S-2 as an example.
- E = electrode (can carry current)
- R = rod (can be used as a filler rod without current)
- 70 = minimum tensile strength of the deposited weld metal in thousands of psi (70,000 psi)
- S = solid wire
- 2 = chemical composition group (deoxidizer package)
For stainless ER308L: ER = electrode/rod; 308 = alloy type matching 304 stainless base metal; L = low carbon content (0.03% max), which reduces sensitization risk in the heat-affected zone.
For aluminum ER4043: ER = electrode/rod; 40 = alloy family; 43 = specific alloy designation within that family (silicon-bearing alloy, good for 6000-series aluminum).
Filler metals are also assigned F-numbers (F1 through F6 for most arc processes) in ASME Section IX and in AWS D1.1. The F-number groups filler metals with similar usability characteristics for the purpose of welder and procedure qualification. Knowing the F-number lets you determine whether a filler substitution is permitted without re-qualifying a procedure.
Welding Procedure Specifications (WPS)
A WPS is the written recipe a welder follows to produce a weld that meets code. Under AWS D1.1 (structural steel), ASME Section IX (pressure piping and vessels), and other codes, qualified WPSs must be on hand at the work site and available to the welder and inspector.
Key fields you must fill in correctly on a GTAW WPS:
1. Base metal P-number — classifies the base metal by chemistry for qualification purposes
2. Filler metal classification and F-number — AWS designation and the matching F-number
3. Shielding gas type and flow rate — exact gas composition (e.g., 100% Ar) and CFH range
4. Amperage range — minimum and maximum current for the qualified position and thickness
5. Welding position — 1G, 2G, 5G, 6G, etc.
6. Joint design — groove angle, root opening, backing if used
Critical variables are those variables whose change requires re-qualification of the procedure. Shielding gas type, filler metal classification, base metal P-number, and position are all critical variables under most codes. An error in any of these fields on a WPS invalidates the document for code compliance.
Safety Reminders for GTAW Operations
- Wear proper shade lens (typically shade 9–13 for GTAW, per lens shade selection charts)
- Use leather gloves; GTAW gloves are thinner than SMAW gloves to allow dexterity, but still required
- Keep the tungsten electrode ground or prepared correctly to prevent contamination of the weld pool
- Never touch a hot tungsten or weld puddle — burns are severe
- Ensure fume extraction is active, especially on stainless steel (hexavalent chromium hazard)
Key terms9
Shielding gasAn inert or semi-inert gas (commonly argon or argon-helium blends) directed over the weld pool and tungsten electrode to exclude oxygen and nitrogen from the arc zone during GTAW.
Thermal conductivityA gas property that describes how efficiently heat is transferred through it; helium has much higher thermal conductivity than argon, which raises arc voltage and heat input at the same welding current.
AWS A5-seriesThe family of American Welding Society standards that classify filler metals — including electrodes and rods — by chemical composition, mechanical properties, and intended base metal application.
ER designationAn AWS filler metal prefix indicating the product can serve as both an electrode (E) and a filler rod (R); used in GTAW and GMAW classifications such as ER70S-2 and ER308L.
F-numberA grouping number assigned by ASME Section IX and AWS codes that clusters filler metals with similar usability characteristics; determines whether a filler metal substitution requires re-qualification of the welding procedure.
P-numberA code-assigned grouping number for base metals with similar chemical and mechanical properties; used in WPS and welder qualification records to identify which metals a procedure covers.
Welding Procedure Specification (WPS)A written document that prescribes the variables — base metal, filler metal, shielding gas, current, position, and joint design — required to produce a weld meeting a specific code.
Critical variableA WPS element (such as shielding gas type, filler metal classification, or base metal P-number) whose change requires the welding procedure to be re-qualified under the applicable code.
Simple asphyxiantA non-toxic gas such as argon or helium that poses a hazard not by being poisonous, but by displacing oxygen in confined or poorly ventilated spaces, potentially causing unconsciousness or death.
Worked examples4
1. Decode the AWS filler metal designation ER308L and identify its intended base metal application.
- Step 1 — Read the prefix: 'E' means electrode (can carry current); 'R' means rod (can be used without current as a filler rod). So ER = electrode/rod, usable in GTAW as a filler rod.
- Step 2 — Read the alloy number: '308' identifies the stainless steel alloy type. AWS A5.9 defines 308 as an 18% chromium / 10% nickel composition, designed to match or overmatch 304 and 304L stainless base metals.
- Step 3 — Read the suffix: 'L' stands for low carbon — the deposited weld metal contains 0.03% carbon maximum. Low carbon reduces carbide precipitation in the heat-affected zone, which lowers the risk of intergranular corrosion (sensitization).
- Step 4 — Match to base metal: ER308L is the standard filler metal for welding 304 and 304L austenitic stainless steel, which are common in food-service equipment, pharmaceutical piping, and structural stainless applications.
Answer: ER308L is an electrode/rod for GTAW (and GMAW) classified under AWS A5.9; it is an 18Cr-10Ni, low-carbon stainless filler metal used to weld 304 and 304L stainless steel base metals.
2. A welder switches from 100% argon at 20 CFH to a 75% argon / 25% helium blend on a 3/8-inch stainless steel groove weld. The instructor notes the bead width increased from 0.35 inches to 0.44 inches on cross-section samples. Calculate the percent increase in bead width.
- Step 1 — Identify the two values: original bead width = 0.35 in; new bead width = 0.44 in.
- Step 2 — Calculate the difference: 0.44 − 0.35 = 0.09 in.
- Step 3 — Divide the difference by the original value: 0.09 ÷ 0.35 = 0.2571…
- Step 4 — Convert to percent: 0.2571 × 100 ≈ 25.7%.
Answer: The bead width increased by approximately 25.7%, consistent with the higher heat input produced by the helium-bearing blend raising arc voltage and widening the arc cone.
3. On a WPS for GTAW of carbon steel pipe, the engineer specifies ER70S-2 filler at a flow rate of 18 CFH argon. The inspector finds the welder used ER70S-6 and set flow to 18 CFH. Is the filler substitution a critical variable change requiring re-qualification?
- Step 1 — Identify the filler metals: ER70S-2 and ER70S-6 are both classified under AWS A5.18, both are F-number 6 solid carbon steel filler metals.
- Step 2 — Check the applicable code rule: Under ASME Section IX, filler metals within the same F-number group may generally be substituted without re-qualifying the procedure, because F-number grouping indicates equivalent usability characteristics.
- Step 3 — Check chemistry: ER70S-2 contains aluminum, titanium, and zirconium deoxidizers; ER70S-6 has higher manganese and silicon. For code qualification purposes the F-number is the controlling factor, not the suffix chemistry difference.
- Step 4 — Conclusion: Because both fillers share the same F-number (F-6) under ASME Section IX, the substitution of ER70S-6 for ER70S-2 does not require procedure re-qualification under that code. However, always confirm with the project engineer and the specific edition of the code in effect on your job, as contract documents may impose additional restrictions.
Answer: No re-qualification is required under ASME Section IX because ER70S-2 and ER70S-6 share the same F-number (F-6); confirm with the applicable code edition and project engineer before making any substitution.
4. A student measures shielding gas flow with a flowmeter and reads 12 CFH of 100% argon on a 1/2-inch stainless GTAW groove weld. The WPS requires 18–22 CFH. By how many CFH must flow increase at minimum to meet the WPS?
- Step 1 — Identify the required minimum from the WPS: 18 CFH.
- Step 2 — Identify the current reading: 12 CFH.
- Step 3 — Calculate the shortfall: 18 − 12 = 6 CFH.
- Step 4 — State the answer: Flow must increase by at least 6 CFH to reach the WPS minimum of 18 CFH.
Answer: The flow rate must increase by at least 6 CFH (from 12 CFH to a minimum of 18 CFH) to comply with the WPS. Welding below the specified flow rate risks inadequate shielding coverage and atmospheric contamination of the weld pool.
The math in this lesson1
Learners compute the percent bead-width increase from 0.35 to 0.44 in and the CFH shortfall against a WPS range.
7.RP.3
In class: Comparative arc demonstration (instructor): run identical beads on stainless with 100% argon and a 75/25 argon-helium blend; students measure bead width and penetration depth from cross-sections and record differences in a data table. · Filler metal classification drill: students receive a list of 10 AWS filler designations (ER70S-2, ER308L, ER4043, etc.) and decode each prefix, suffix, and number using an AWS A5-series key card, then match each to its intended base metal. · WPS completion exercise: using a blank AWS-format WPS template, students fill in joint design, base metal P-number, filler metal F-number, shielding gas type and flow rate, amperage range, and position for a given GTAW scenario; instructor reviews entries against a model WPS.
Materials: AWS A5.18, A5.9, A5.10 filler metal standard handouts, blank WPS template (AWS format), polished and etched cross-section samples of argon vs. argon-helium welds, flowmeters, AWS D1.1 structural code (relevant sections), projector/whiteboard
Check: Written WPS completed with no more than two errors in critical variables (base metal, filler, shielding gas, position); filler metal classification drill score 80% or higher — both criteria required to pass.