BLD-WELD01-05 · Lesson 2 · 10 clock hours · demo
Wire Selection, Shielding Gas, and Machine Setup
Objective. Students will select the correct AWS A5.20 or A5.36 wire classification and shielding gas mixture for a given base metal and position, then set voltage, wire feed speed, and inductance on a CV power source to within the WPS-specified range.
What Is FCAW and Why Wire Selection Matters
Flux-Cored Arc Welding (FCAW) uses a continuously fed tubular wire electrode whose hollow core contains flux ingredients. Those ingredients shield the arc, control the weld chemistry, and determine what positions and base metals the wire suits. Choosing the wrong wire for the job produces porosity, cracking, or mechanical properties that fall short of the Welding Procedure Specification (WPS). Your first task on any FCAW job is to match the wire classification to the base metal, joint position, and shielding gas already written into the WPS.
Reading an AWS A5.20 or A5.36 Classification
AWS A5.20 covers carbon-steel FCAW electrodes; AWS A5.36 is a newer, open-classification standard that allows manufacturers more flexibility in reporting optional designators. Both use the same basic prefix structure.
Take E71T-1C-H8 as an example and read it digit by digit:
- E — electrode
- 7 — minimum tensile strength in units of 10 ksi (70 ksi minimum)
- 1 — usability position: 1 = all positions; 0 = flat and horizontal only
- T — tubular (flux-cored)
- -1 — usability designator; indicates flux type, polarity, and shielding gas family (T-1 wires run DCEP with external gas)
- C — shielding gas: C = 100% CO₂; M = 75% Ar / 25% CO₂ (C25); some classifications list both (e.g., T-1C/M)
- H8 — optional diffusible hydrogen designator: maximum 8 mL of hydrogen per 100 g of deposited weld metal; lower numbers (H4, H2) indicate even drier deposits and reduce the risk of hydrogen-induced cracking
Under A5.36, an open-classification wire may carry designators such as T15-M21-A8-CS1-H4, encoding flux type, gas group, composition, and hydrogen level in a slightly expanded format. Your classification chart decodes each field.
Gas-Shielded (FCAW-G) vs. Self-Shielded (FCAW-S)
FCAW-G wires (T-1, T-2, T-9, T-12, and others) require external shielding gas. Common choices:
- 75% Ar / 25% CO₂ (C25): lower spatter, smoother bead, good for out-of-position work
- 100% CO₂: deeper penetration, slightly more spatter, lower cost, preferred by some codes for certain groove welds
Check the wire classification — the letter after the dash (C or M) tells you which gas the wire is qualified for. Using the wrong gas voids the electrode's classification and can violate the WPS.
FCAW-S wires (e.g., E71T-8, E70T-7) contain all shielding in the core; they run without any cylinder gas. They are useful in wind or outdoors where external gas would blow away, but they typically generate more fume and require strict attention to electrode extension (stickout) to maintain adequate self-shielding. Never apply external shielding gas to an FCAW-S wire — it disrupts the core chemistry.
Machine Setup on a CV Power Source
FCAW runs on a constant-voltage (CV) power source. The machine holds voltage essentially steady while wire feed speed (WFS) controls amperage. The three essential variables you will set are:
1. Voltage (V): controls arc length and bead width. Too low = stubbing, cold lap. Too high = excessive spatter, undercut.
2. Wire Feed Speed (WFS, in inches per minute, ipm): directly sets amperage for a given wire diameter. Higher WFS = higher amperage = deeper penetration.
3. Inductance (if available): controls how quickly current rises at arc start. Higher inductance softens the arc and reduces spatter; lower inductance gives a crisper, faster-freezing puddle useful for out-of-position work.
Always set voltage and WFS to the values written in the WPS before you strike an arc. A typical starting range for .045 in. E71T-1C on 3/8 in. plate in the flat position is roughly 26–29 V and 350–450 ipm, but your WPS is the authority — not memory.
Loading Wire and Setting Electrode Extension
1. Verify the drive roll groove size matches the wire diameter (knurled rolls for flux-cored wire).
2. Feed the wire through the inlet guide, drive rolls, cable liner, and contact tip. Trim the wire flush at the tip, then pull out 3/4 in. (approximately 19 mm) as your initial electrode extension (stickout). Electrode extension for FCAW-G is typically 3/4 in. to 1 in.; FCAW-S may require longer extension per the manufacturer.
3. Set gas flow with a flowmeter. Most FCAW-G procedures call for roughly 35–50 CFH; confirm your WPS value. Check for drafts — even a light breeze can disrupt shielding.
4. Verify contact tip size matches wire diameter. A mismatched tip causes erratic feeding and arc instability.
Safety Points
- Fume extraction: FCAW produces more fume than GMAW. Use local exhaust ventilation (LEV) or a fume extraction gun. Never weld over galvanized or coated steel without engineering controls and awareness of toxic oxide risks.
- PPE: minimum shade 10 lens for most FCAW amperages (verify ANSI Z87.1 / AWS F2.2 filter shade table); leather gloves, flame-resistant jacket, and leather boots.
- Cylinder safety: chain all cylinders upright; keep caps on when not in use; never use cylinders as rollers or stands.
- Wire and drive rolls: de-energize and follow lockout/tagout (LOTO) procedures before changing drive rolls, liners, or contact tips — the wire feeder can feed unexpectedly if the trigger is bumped.
- Spatter burns: FCAW-G with CO₂ can throw spatter several feet. Clear the area and use spatter-resistant spray on fixtures.
Key terms10
AWS A5.20The AWS filler metal specification that classifies carbon-steel flux-cored arc welding electrodes, defining mechanical properties, usability, shielding gas, and optional diffusible hydrogen requirements.
AWS A5.36A newer AWS specification using an open-classification system for carbon and low-alloy steel FCAW and GMAW-S electrodes, allowing manufacturers to report flux type, gas group, composition, and hydrogen level with expanded designators.
Constant-Voltage (CV) Power SourceA welding power source that maintains a nearly fixed output voltage while current varies automatically with wire feed speed; the standard power source type for FCAW and GMAW.
Wire Feed Speed (WFS)The rate, in inches per minute (ipm), at which electrode wire is driven through the gun; on a CV machine, WFS is the primary control for welding amperage.
Diffusible Hydrogen DesignatorAn optional suffix on an electrode classification (H16, H8, H4, H2) indicating the maximum milliliters of diffusible hydrogen per 100 grams of deposited weld metal; lower values reduce risk of hydrogen-induced cracking.
Electrode Extension (Stickout)The distance from the end of the contact tip to the end of the wire; for FCAW-G this is typically 3/4 in. to 1 in. Longer extension increases electrical resistance, raises heat in the wire, and can affect shielding effectiveness.
FCAW-S (Self-Shielded)A variant of flux-cored arc welding in which all shielding comes from elements within the wire core; no external cylinder gas is used, making it suitable for outdoor or windy conditions.
InductanceA power source setting that controls the rate of current rise during short-circuit events; higher inductance produces a softer arc with less spatter, while lower inductance gives a crisper, faster-freezing arc.
Welding Procedure Specification (WPS)A written document that specifies essential and non-essential variables — including voltage, WFS, shielding gas type and flow rate, and position — that a welder must follow to produce a code-compliant weld.
Shielding Gas Flow RateThe volume of shielding gas delivered to the weld zone per unit of time, measured in cubic feet per hour (CFH) and set with a flowmeter; too low allows atmospheric contamination, too high causes turbulence and porosity.
Worked examples4
1. A WPS calls for a shielding gas flow rate of 40 CFH. Your flowmeter reads 33 CFH. How many CFH must you increase flow, and is this within or outside the ±2 CFH acceptance tolerance specified for the setup check?
- Identify the WPS target: 40 CFH.
- Identify the acceptable range: 40 − 2 = 38 CFH minimum, 40 + 2 = 42 CFH maximum.
- Current reading is 33 CFH.
- Difference from target: 40 − 33 = 7 CFH below minimum.
- Required increase: turn the regulator until the flowmeter reads 40 CFH — an increase of 7 CFH.
- Confirm 40 CFH is within the 38–42 CFH window.
Answer: You must increase flow by 7 CFH to reach 40 CFH. The original reading of 33 CFH is 5 CFH outside the ±2 CFH tolerance band (38–42 CFH), so it would have failed the setup check.
2. A WPS specifies 27 V and 400 ipm WFS. After setting the machine, your digital meters read 25.3 V and 440 ipm. Determine which parameters are within the ±2 V / ±50 ipm acceptance tolerance.
- Voltage tolerance band: 27 − 2 = 25 V minimum, 27 + 2 = 29 V maximum.
- Measured voltage: 25.3 V. Is 25.3 ≥ 25? Yes. Is 25.3 ≤ 29? Yes. Voltage is within tolerance.
- WFS tolerance band: 400 − 50 = 350 ipm minimum, 400 + 50 = 450 ipm maximum.
- Measured WFS: 440 ipm. Is 440 ≥ 350? Yes. Is 440 ≤ 450? Yes. WFS is within tolerance.
- Both parameters pass.
Answer: Both 25.3 V (within 25–29 V) and 440 ipm (within 350–450 ipm) are within the specified tolerances. The setup passes both checks.
3. Decode each part of the electrode classification E70T-4 and identify whether external shielding gas is required.
- E — electrode.
- 7 — minimum tensile strength designator: 70 ksi minimum tensile strength.
- 0 — position: flat and horizontal only.
- T — tubular flux-cored electrode.
- -4 — usability designator T-4: self-shielded (FCAW-S), DCEP or DCEN depending on manufacturer data sheet; no external shielding gas listed.
- Because the classification ends at T-4 with no gas letter (C or M), this is a self-shielded wire — no external shielding gas cylinder is used.
Answer: E70T-4 is a self-shielded, flat/horizontal-only flux-cored electrode with 70 ksi minimum tensile strength. No external shielding gas is required or should be applied.
4. You are welding with .045 in. E71T-1C wire. The WPS allows 26–28 V and 380–430 ipm. You want to set the midpoint of each range. What voltage and WFS should you dial in?
- Voltage midpoint: (26 + 28) ÷ 2 = 54 ÷ 2 = 27 V.
- WFS midpoint: (380 + 430) ÷ 2 = 810 ÷ 2 = 405 ipm.
- Set the machine to 27 V and 405 ipm.
- Verify with digital meters that readings fall within the WPS range before welding.
Answer: Set voltage to 27 V and WFS to 405 ipm to operate at the midpoint of the WPS range.
The math in this lesson1
Learners check meter readings against ±2 V and ±50 ipm tolerances and find midpoints of WPS voltage and wire-feed ranges.
N-Q.3
In class: Instructor demonstrates how to read an AWS A5.20 electrode classification (e.g., E71T-1C-H8) digit by digit, decoding usability, flux type, and diffusible hydrogen designator; students decode three additional classifications on a worksheet. · Hands-on machine setup drill: each student loads a spool of E71T-1C wire, threads it through the drive rolls and liner, trims the electrode extension to 3/4 in., sets voltage and wire feed speed per a provided WPS, and verifies shielding gas flow rate with a flowmeter. · Parameter comparison runs: students run short beads at three different voltage/WFS combinations on scrap plate, compare bead width, crown height, and spatter level, and record findings in a process variable log.
Materials: CV power source with digital meters, wire feeder, E71T-1C .045 in. and 0.035 in. wire spools, E71T-8 self-shielded wire, 75%Ar/25%CO2 and 100% CO2 cylinders with regulators and flowmeters, drive roll sets, contact tips and liners, scrap 3/8 in. A36 plate, WPS handout, AWS A5.20/A5.36 classification chart
Check: Students successfully set up the machine to match all essential variables on an instructor-provided WPS (voltage ±2 V, WFS ±50 ipm, gas flow ±2 CFH) with no prompting; instructor signs setup checklist; pass requires all three parameters within tolerance.
Practice check8
Answer each question, then check it. Nothing is recorded; this is your own practice.
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.