MFG-CNC14-06 · Lesson 11 · 14 clock hours · lab
First-Article Inspection and Part Disposition
Objective. Students measure every print-specified feature on a first-off part using the correct gaging for each feature type, record results on a first-article inspection (FAI) form, and make a documented accept, rework, or scrap disposition based solely on the measured evidence.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by a licensed engineer or certified journey-level tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
What Is a First-Article Inspection?
A first-article inspection (FAI) is a structured, documented measurement of every print-specified feature on the very first part produced from a new or revised setup. Its purpose is simple: confirm that the machine, tooling, fixturing, and program together produce a part that matches the engineering drawing before a full production run begins. Scrapping one first-off part costs far less than scrapping a batch or, worse, shipping non-conforming parts to a customer.
The FAI is not a spot-check. Every feature called out on the drawing must be measured, recorded, and dispositioned. The result is a completed FAI form that becomes a permanent quality record.
Reading the Drawing Before You Pick Up a Gage
Start at the title block. Confirm part number, revision level, material, and any general tolerance notes. Then walk the drawing feature by feature. For each feature, ask two questions: What is the nominal dimension and its tolerance? Which gage is capable of resolving that tolerance?
A rule of thumb used throughout the trade is the 10:1 gage-to-tolerance ratio: your measuring instrument should have a resolution and accuracy at least ten times finer than the tolerance band. A ±0.010 in tolerance allows a caliper; a ±0.001 in tolerance demands a micrometer or bore gage.
Selecting the Right Gage for Each Feature Type
| Feature | Recommended Gage |
|---|---|
| Outside diameter | Outside micrometer |
| Bore (internal diameter) | Telescoping gage + micrometer, or bore gage |
| Length / step | Digital calipers or micrometer |
| Surface finish (Ra) | Surface roughness comparator |
| Angular chamfer | Protractor or angle gage |
| Thread | GO/NO-GO thread gage |
GO/NO-GO thread gages work on the Taylor Principle. The GO member checks that the full thread form fits (pitch diameter, lead, and flank angle all within limits). The NO-GO member checks that the pitch diameter is not beyond the maximum-material limit. A conforming thread accepts the GO ring and rejects the NO-GO ring. If the GO ring will not enter, the thread is undersize or damaged. If the NO-GO ring enters fully, the thread is oversized and the part is non-conforming.
Measuring Bores Safely and Accurately
A telescoping gage transfers the bore diameter to a micrometer for the actual reading. Compress the plungers, insert the gage at a slight angle, allow it to expand to the bore wall, then tilt it to the bore axis while locking the plunger. Remove and measure across the plunger heads with the matching outside micrometer. Take at least two readings 90° apart to detect out-of-round conditions. A bore gage with a dial or digital indicator is faster and reads directly but must be calibrated to a ring gage or micrometer setting before use.
Completing the FAI Form
For every feature, the form captures:
- Feature description (e.g., "Ø0.750 OD")
- Nominal dimension
- Upper and lower limits
- Actual measured value
- In tolerance (Y/N)
- Disposition
Write every number you read — do not round toward the tolerance limit to make a borderline value look good. Falsifying inspection records is a serious professional and legal violation in regulated industries.
Making the Disposition
Three outcomes are possible for each out-of-tolerance feature:
1. Accept as-is — only valid with written engineering disposition (a deviation or waiver). You cannot unilaterally accept a non-conforming feature.
2. Rework — material can be removed or a feature corrected and brought into tolerance. A diameter that is 0.002 in oversize on an OD can be taken to size; a diameter that is 0.002 in undersize on an OD cannot be built back up without a process such as welding, which requires separate engineering approval.
3. Scrap — the feature cannot be corrected. Record the specific reason (e.g., "bore 0.005 in undersize, no material to remove").
The disposition must be based on measured evidence recorded on the form — not on intuition, appearance, or what you expect the machine to have done.
Safety in the Inspection Area
- Deburr parts before handling. Sharp edges and chips cause lacerations; wear cut-resistant gloves when carrying freshly machined parts to the inspection station.
- Cleaning fluid and coolant residue on parts can be slippery and irritating; use a lint-free cloth and approved part-washing solvent in a ventilated area; consult the SDS for the solvent in use.
- Gage handling: Micrometers and bore gages are precision instruments; dropping them on the concrete floor alters calibration. Store in cases when not in use.
- Lockout/tagout is not required at the inspection bench, but if you must return to the machine to make an adjustment after the FAI reveals an out-of-tolerance feature, full LOTO procedures apply before touching any machine component.
Comparing to the CMM Report
A coordinate measuring machine (CMM) is a reference-grade instrument. Your hand-gage measurements will be compared to CMM values at the end of this lab. Differences larger than ±0.001 in on the same feature point to a technique error, a gage that needs calibration, or a gage that is under-qualified for that tolerance. Use the comparison as a learning tool, not a shortcut — the CMM report is instructor reference only during this exercise.
Key terms9
First-Article Inspection (FAI)A complete, documented measurement of every print-specified feature on the first part produced from a new or revised setup, used to confirm conformance before full production begins.
DispositionThe documented decision made for each inspected feature: accept as-is (with engineering authority), rework, or scrap, based solely on measured evidence.
GO/NO-GO Thread GageA fixed-limit attribute gage set used to verify that a threaded feature falls within its specified pitch-diameter tolerance; the GO member must enter and the NO-GO member must not enter for the part to conform.
Bore GageA direct-reading internal measuring instrument, set to a reference diameter, that indicates deviation from that reference when inserted into a bore; used for accurate internal-diameter measurement.
Telescoping GageA transfer instrument with spring-loaded plungers that expand to the bore wall; the locked plunger span is then measured with an outside micrometer to obtain the internal diameter.
Surface Roughness ComparatorA reference plate carrying standardized machined surfaces of known Ra values, used to estimate a part's surface finish by visual and tactile comparison.
10:1 Gage-to-Tolerance RatioA widely applied industry guideline stating that a measuring instrument's resolution and accuracy should be at least ten times finer than the tolerance being checked.
ReworkA disposition indicating that an out-of-tolerance feature can be corrected by additional machining or processing to bring it within print specification.
CMM (Coordinate Measuring Machine)A reference-grade instrument that uses a touch probe moving in three axes to measure part geometry with very high accuracy; its output is used as ground-truth comparison in this lab.
Worked examples4
1. The drawing calls for an outside diameter of 1.250 in with a bilateral tolerance of ±0.002 in. Your 1–2 in outside micrometer reads 1.2534 in. Is the feature in tolerance, and what is the deviation from nominal?
- Identify the limits: Lower limit = 1.250 − 0.002 = 1.248 in; Upper limit = 1.250 + 0.002 = 1.252 in.
- Compare the actual reading: 1.2534 in versus the upper limit of 1.252 in.
- Calculate deviation from nominal: 1.2534 − 1.250 = +0.0034 in (0.0034 in oversize).
- Since 1.2534 in is greater than the upper limit of 1.252 in, the feature is OUT OF TOLERANCE.
Answer: The OD reads +0.0034 in from nominal and exceeds the upper limit by 0.0014 in. Record actual value 1.2534 in on the FAI form, mark 'N' for in-tolerance, and evaluate for rework (material can be removed to reduce the diameter to within 1.248–1.252 in).
2. A bore is specified as 0.875 in diameter with a unilateral tolerance of +0.003/−0.000 in (a minimum-material-condition bore). Your telescoping gage, measured with a 0–1 in outside micrometer, gives 0.8768 in. Determine conformance.
- Identify the limits: Lower limit = 0.875 + 0.000 = 0.875 in; Upper limit = 0.875 + 0.003 = 0.878 in.
- Compare actual: 0.8768 in versus limits 0.875–0.878 in.
- Check lower limit: 0.8768 ≥ 0.875 ✓
- Check upper limit: 0.8768 ≤ 0.878 ✓
Answer: The bore at 0.8768 in falls within 0.875–0.878 in. Record actual 0.8768 in, mark 'Y' for in-tolerance. No disposition action required for this feature.
3. A thread is specified as 1/2-13 UNC-2B (internal). You apply the GO thread plug gage: it enters the full thread length. You apply the NO-GO plug gage: it also enters the full thread length. What is the correct disposition?
- Recall the acceptance rule: GO must enter (confirms minimum material is present and thread form is correct); NO-GO must NOT enter (confirms pitch diameter has not exceeded the maximum limit).
- GO entered — this condition is satisfied.
- NO-GO also entered — this means the pitch diameter has exceeded its maximum limit; the thread is oversized.
- An oversized internal thread cannot be corrected by removing material in a useful way (making the bore larger would worsen the condition, and the thread form is already cut).
Answer: The thread is OUT OF TOLERANCE — oversized. Record 'NO-GO entered' on the FAI form, mark 'N' for in-tolerance, and disposition as SCRAP with reason: 'Internal thread pitch diameter exceeds maximum limit; condition not reworkable.'
4. The drawing specifies a chamfer angle of 45° ±2°. Your protractor reads 43.5°. Calculate the deviation and state the disposition.
- Identify the limits: Lower limit = 45 − 2 = 43°; Upper limit = 45 + 2 = 47°.
- Compare actual: 43.5° versus limits 43°–47°.
- Deviation from nominal: 43.5 − 45 = −1.5° (1.5° below nominal).
- 43.5° ≥ 43° lower limit ✓ and 43.5° ≤ 47° upper limit ✓.
Answer: The chamfer at 43.5° is within the ±2° tolerance band (43°–47°). Record actual 43.5°, mark 'Y' for in-tolerance. No disposition action required.
The math in this lesson1
Learners compute upper and lower tolerance limits and deviation from nominal to accept, rework, or scrap features.
N-Q.3
In class: Instructor distributes a part drawing with eight specified features (two diameters, one bore, two lengths, one surface finish, one angular chamfer, one thread); students identify the correct gage for each feature before measuring begins. · Students measure all eight features on their first-off part, recording nominal, tolerance, and actual values on the FAI form; they apply GO/NO-GO gages to the thread and bore as appropriate. · Students write a disposition statement for each out-of-tolerance feature (rework path or scrap reason) and discuss total decisions as a class; instructor reveals true values from a CMM report for comparison.
Materials: First-off milled or turned part (from Lesson 8 or 9), part drawing, FAI form, 0–1 in and 1–2 in outside micrometers, digital calipers, telescoping gage set, bore gage, surface roughness comparator, GO/NO-GO thread gage, protractor, CMM report (instructor reference)
Check: All eight feature measurements within ±0.001 in of CMM reference values; disposition on each feature matches CMM-based ground truth; FAI form fully completed — 7 of 8 features correctly measured and correctly dispositioned required to pass.
Practice check8
Answer each question, then check it. Nothing is recorded; this is your own practice.
Record this lesson on my transcript. Sign in with your key and enrollment email to record lessons (enroll free if you have no key). This page stays open to read and practise.