Objective. Students will identify the major components of CCTV and intrusion-alarm systems, explain applicable low-voltage safety rules, and demonstrate correct personal protective equipment selection for installation work.
This lesson, its worked examples and its practice questions has not yet been verified by a credentialed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Before you pull a single wire or mount a single camera, you need a clear mental map of how CCTV and intrusion-alarm systems are built, what safety rules govern low-voltage electrical work, and which personal protective equipment (PPE) belongs on your body during installation. These foundations protect you, your co-workers, and your customers — and they are the first things a licensing board or credentialing exam will test.
An intrusion-alarm system has four functional layers: detection, processing, notification, and power.
Control panel (alarm panel): The brain of the system. It receives signals from detectors, processes them against programmed zones, and triggers outputs such as sirens or communicator calls. The panel is usually housed in a metal enclosure and runs on 12 V DC supplied by its own transformer and standby battery.
Passive infrared (PIR) sensor: Detects changes in infrared energy caused by a moving body. Most residential and light-commercial PIRs operate at 9–15 V DC and draw only milliamps. They are "passive" because they emit nothing — they only listen.
Door and window contacts: Magnetic reed switches that open or close a circuit when a door or window moves. Simple, reliable, and very low current.
Keypad: The user interface. Keypads communicate with the panel over a data bus, typically 4-wire (power, ground, data, clock).
Siren/sounder and strobe: Output devices. Verify voltage and current ratings before wiring; exceeding the panel's output capacity can damage the panel.
Communicator/dialer: Sends alerts over a phone line, cellular network, or IP path to a central monitoring station.
Standby battery: A sealed lead-acid (SLA) battery, usually 12 V, that keeps the system running during a power outage. Panels are designed to support a minimum standby period — always check the manufacturer specification.
Power supply/transformer: Steps utility AC voltage down and converts it to regulated DC for the panel and devices.
Camera (analog or IP): Captures video. Analog cameras output a composite video signal over coaxial cable. IP cameras digitize the image on-board and transmit data over a network cable. Both types specify a field of view, resolution, and minimum illumination rating.
Digital video recorder (DVR) / Network video recorder (NVR): The DVR digitizes and stores analog camera feeds; the NVR stores streams from IP cameras. Both require adequate storage capacity and network or coaxial connectivity.
Power supply: Cameras may be powered by a centralized multi-camera supply, by individual plug-in adapters, or — for IP cameras — by Power over Ethernet (PoE) from a PoE switch or injector.
Monitors and remote viewing clients: Output devices for live or recorded footage.
The National Electrical Code (NEC) classifies alarm and signal wiring under Article 725 (remote-control, signaling, and power-limited circuits) and CCTV/audio wiring under Article 760 (fire-alarm systems share Article 760 as well). These articles define wire types, separation requirements from power wiring, and installation methods. Always consult the authority having jurisdiction (AHJ) — your local building or fire inspector — for any project-specific interpretation.
"Low voltage" does not mean "no hazard." Key safety points:
| Task | Minimum PPE |
|---|---|
| Opening an energized panel or working near AC terminals | Safety glasses, insulated gloves (Class 00 minimum for 120 V AC) |
| Drilling overhead or into walls | Safety glasses, dust mask |
| Climbing a ladder | Hard-soled non-slip footwear; hard hat if work is below others |
| Cutting or stripping wire | Safety glasses |
Never substitute fashion gloves or rubber dishwashing gloves for rated insulated gloves. Check that insulated gloves carry the ASTM voltage-class marking.
| Wire | Typical Application | NEC Article |
|---|---|---|
| RG-59 coaxial | Analog CCTV, short to medium runs | 820 |
| RG-6 coaxial | Analog CCTV, longer runs; better shielding | 820 |
| 18/2 or 18/4 alarm wire (unshielded) | Sensor loops, keypad wiring, siren runs | 725 |
| CAT5e / CAT6 (UTP) | IP cameras, keypad data buses, access control | 725 |
| 16/4 or 18/4 (multi-conductor) | PIR power and data, multi-wire sensor runs | 725 |
Always verify maximum run distances from the manufacturer's data sheet for the specific device — the data sheet overrides a general rule of thumb.
When you receive a component, find the data sheet (often inside the box or on the manufacturer's website). Locate: operating voltage range, current draw (quiescent and alarm), wire-gauge recommendation, and maximum zone loop resistance. Record these before you design or run any wire. Undersized wire over a long run creates voltage drop that can prevent a detector from operating correctly.