TEC-ELEC48-04 · Lesson 8 · 16 clock hours · lab
Fusion Splicing
Objective. Students will perform fusion splices on singlemode and multimode fiber using an arc fusion splicer and achieve estimated splice loss within the equipment's pass threshold on at least 4 of 5 splices.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by an industry-certified professional or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
What Is Fusion Splicing?
Fusion splicing is the process of permanently joining two optical fibers end-to-end by melting them together with a precisely controlled electric arc. The result is a continuous glass path that carries light with very low signal loss — typically well under 0.10 dB on singlemode fiber when the splice is done correctly. Because no connector is involved, fusion splices outperform mechanical splices in both loss and long-term reliability, making them the standard method for outside-plant and high-performance inside-plant fiber runs.
How an Arc Fusion Splicer Works
A modern arc fusion splicer holds two prepared fiber ends in V-grooves and uses a camera and image-processing software to align the cores automatically. Once alignment is confirmed, the machine fires a high-voltage arc between two tungsten electrodes. The arc briefly liquefies the glass at the fiber tips, and the machine pushes the fibers together so the molten ends fuse into one piece. After the arc, the splicer displays an estimated splice loss (ESL) — an optical calculation based on core alignment and geometry. This is an estimate, not a measured value; an optical time-domain reflectometer (OTDR) or optical loss test set gives the true insertion loss after the splice is protected and installed.
Fiber Preparation: The Critical Step
More than any other variable, cleave quality determines splice loss. A poor cleave — one that is angled, chipped, or has a lip — prevents the molten ends from fusing cleanly, creating air gaps, bubbles, or core offsets.
Follow this preparation sequence every time:
1. Strip the buffer coating back at least 30–40 mm using a buffer striper sized for your fiber. Remove all coating completely.
2. Clean the bare glass with a fresh lint-free wipe moistened with isopropyl alcohol (IPA, 99% pure). Wipe in one direction only; never re-use the wipe on the same fiber.
3. Cleave the fiber with a precision cleaver set to the blade position and length your splicer manufacturer specifies (commonly 8–16 mm of bare fiber, depending on splicer model). A properly cleaved end face is flat and perpendicular — a cleave angle under 0.5° is ideal for singlemode.
4. Do not touch the cleaved end face or let it contact any surface before loading into the splicer.
Loading, Aligning, and Fusing
Open the splicer wind cover and place each prepared fiber into its V-groove with the cleaved end positioned just inside the electrode gap. Close the cover — this triggers the auto-align and pre-fusion sequence on most machines. The splicer:
- Fires a brief cleaning arc to burn off residual contaminants
- Captures images and aligns cores (X, Y, and sometimes angular)
- Performs the main fusion arc
- Displays the ESL
If the ESL exceeds the pass threshold (the splicer's limit, often ≤ 0.10 dB for singlemode and somewhat higher for multimode), inspect the error message. The splicer may flag a bubble, a fat or thin fiber, or excessive core offset. Re-do the splice: re-cleave both fibers and repeat. Never re-arc a failed splice without re-cleaving.
Splice Protection
A fusion splice is mechanically fragile until protected. Slide a heat-shrink splice protection sleeve over the splice before cleaving — this is a common beginner error to avoid. The sleeve contains a stainless-steel rod and a hot-melt adhesive layer. Center it over the splice and place it in the splicer's heat oven. The oven shrinks the sleeve tightly around the fiber, providing bend resistance and environmental sealing. Allow it to cool before handling.
Splice Tray Loading and Bend Radius
Protected splices are coiled and stored in a splice tray inside a splice closure or enclosure. When loading:
- Observe the minimum bend radius for your fiber type (check the fiber data sheet; a common guideline for standard singlemode is no tighter than 30 mm diameter coil, though some bend-insensitive fibers allow tighter routing).
- Lay excess fiber in smooth coils in the tray channels; do not kink or cross fibers sharply.
- Seat each protected splice in its retaining clips.
- Photograph the finished tray for your lab log before closing.
Safety
Cleaved fiber shards are extremely hazardous. Bare glass slivers are invisible, nearly impossible to remove from skin, and can penetrate the eye. Follow these rules at all times:
- Wear safety glasses whenever handling bare fiber.
- Dispose of all cleaved fiber ends and stripped buffer debris in a designated puncture-resistant sharps container — never in an open trash can or on the bench where they can stick to clothing.
- Never look into a live fiber end; although training fiber is dark, treat every fiber as potentially live.
- IPA is flammable — keep it away from the arc splicer's heat oven and open arcs; cap the bottle when not in use.
- The fusion arc produces UV radiation; keep the splicer wind cover closed during arcing.
- Follow your facility's lockout/tagout procedures when working inside any energized enclosure or splice case that involves electrical equipment.
Key terms8
Fusion spliceA permanent joint between two optical fibers made by melting the glass ends together with an electric arc, producing very low insertion loss.
Estimated splice loss (ESL)The optical loss value displayed by the fusion splicer after a splice, calculated from core alignment images; it is an approximation, not a directly measured value.
CleaveA controlled break made with a precision cleaver that produces a flat, perpendicular fiber end face suitable for fusion splicing.
Cleave angleThe angle between the fiber end face and a perfect perpendicular plane; low angles (< 0.5°) are required for low-loss singlemode splices.
Heat-shrink splice protection sleeveA tube containing a stainless-steel rod and hot-melt adhesive that is shrunk around a completed fusion splice in a heat oven to provide mechanical protection and environmental sealing.
Buffer striperA hand tool used to strip the polymer coating (buffer) from the bare glass of an optical fiber before cleaving and splicing.
Splice trayA rigid organizer inside a splice closure or enclosure that holds protected fusion splices and stores excess fiber coils at safe bend radii.
Core offsetLateral misalignment of the two fiber cores at a splice joint, one of the primary causes of splice loss.
Worked examples4
1. A student performs three singlemode fusion splices. The splicer displays ESL values of 0.04 dB, 0.09 dB, and 0.12 dB. The pass threshold is 0.10 dB. How many splices pass, and what is the average ESL of the passing splices?
- Identify which splices are at or below 0.10 dB: 0.04 dB ✓, 0.09 dB ✓, 0.12 dB ✗ (exceeds threshold).
- Count passing splices: 2 pass.
- Sum the ESL of passing splices: 0.04 + 0.09 = 0.13 dB.
- Divide by the number of passing splices: 0.13 ÷ 2 = 0.065 dB average.
Answer: 2 splices pass. The average ESL of the passing splices is 0.065 dB.
2. A student must pass at least 4 of 5 singlemode splices at ≤ 0.10 dB. Their recorded ESL values are: 0.05, 0.08, 0.11, 0.07, and 0.09 dB. Does the student meet the lab objective? What is the total estimated loss across all five splices?
- Check each value against 0.10 dB threshold: 0.05 ✓, 0.08 ✓, 0.11 ✗, 0.07 ✓, 0.09 ✓.
- Count passing splices: 4 out of 5 pass — the objective requires at least 4, so the student meets the requirement.
- Sum all five ESL values for total estimated loss: 0.05 + 0.08 + 0.11 + 0.07 + 0.09 = 0.40 dB.
Answer: Yes, the student meets the lab objective (4 of 5 pass). Total estimated loss across all five splices is 0.40 dB.
3. A splice tray holds fiber in a coil. The manufacturer's minimum bend diameter for the singlemode fiber being used is 50 mm. A student coils 1.2 m of excess fiber. Approximately how many full 50 mm-diameter loops fit in 1.2 m of fiber? (Use π ≈ 3.14.)
- Calculate the circumference of one loop at 50 mm diameter: C = π × d = 3.14 × 50 mm = 157 mm = 0.157 m.
- Divide total fiber length by circumference per loop: 1.2 m ÷ 0.157 m/loop ≈ 7.64 loops.
- Round down to whole loops that fit: approximately 7 full loops.
Answer: Approximately 7 full loops at the minimum 50 mm bend diameter fit in 1.2 m of excess fiber.
4. A student's five singlemode ESL readings are 0.06, 0.08, 0.05, 0.09, and 0.07 dB. What is the average ESL, and by how much does the worst splice exceed or fall below the 0.10 dB pass threshold?
- Sum all five values: 0.06 + 0.08 + 0.05 + 0.09 + 0.07 = 0.35 dB.
- Divide by 5 to find average: 0.35 ÷ 5 = 0.07 dB average ESL.
- Identify the worst (highest) splice: 0.09 dB.
- Compare to threshold: 0.10 − 0.09 = 0.01 dB below the threshold, meaning the worst splice still passes with 0.01 dB margin.
Answer: Average ESL is 0.07 dB. The worst splice (0.09 dB) falls 0.01 dB below the pass threshold — all five splices pass.
The math in this lesson1
Learners screen splices against 0.10 dB and average the passing losses: (0.04 + 0.09) / 2 = 0.065 dB.
S-ID.2
In class: Instructor demonstration of the complete fusion splicing sequence: fiber preparation, loading into the splicer, alignment, fusion arc, loss estimation display, and protection sleeve shrinking in the heat oven; students complete a process flowchart worksheet. · Guided practice: students perform 5 singlemode and 5 multimode splices under instructor supervision, recording estimated splice loss for each in their lab log; instructor coaches on cleave quality as the most common error cause. · Splice sleeve installation and splice tray loading: students protect completed splices with heat-shrink sleeves, load them into a splice tray using proper bend radius, and photograph the completed tray for their lab log.
Materials: Arc fusion splicer with spare electrodes, singlemode and multimode fiber (bare and jacketed), heat-shrink splice protection sleeves, splice heat oven, precision cleaver, buffer striper, lint-free wipes, IPA, splice tray, lab log sheets
Check: Student's 5 singlemode splices are reviewed; at least 4 must show estimated splice loss at or below the splicer's pass threshold (typically ≤0.10 dB for SM); instructor records values in lab log and signs off.
Practice check8