Objective. Students will identify electrical shock hazards present at an electronics workbench, select appropriate PPE, and demonstrate the lockout/tagout sequence for a bench DC power supply without error.
This lesson, its worked examples and its practice questions has not yet been verified by an industry-certified professional or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Electrical shock kills and injures workers across every level of voltage. A common misconception among new technicians is that bench-level voltages—12 V, 24 V, 30 V—are automatically safe. In fact, the danger from electricity comes primarily from the amount of current that flows through the body, not the voltage label on the supply. Understanding this principle is the foundation of bench safety.
Ohm's Law tells us that current equals voltage divided by resistance (I = V / R). Human skin resistance varies widely—from roughly 1,000 ohms when wet to 100,000 ohms or more when dry and unbroken. At these ranges, even modest voltages can drive dangerous currents through the body if contact is made with both poles of a circuit.
Generally accepted thresholds (from standard electrical safety references) are:
The key takeaway: currents well under one ampere can kill. A 9 V battery touching wet fingers can push currents into the perception range. A 120 V line supply can easily exceed the lethal threshold through ordinary skin contact.
Extra-Low Voltage (ELV) is generally defined as voltages at or below 50 V AC or 120 V DC (exact thresholds vary by standard; IEC 60364 is a common reference). Most bench DC power supplies operate in ELV territory—0 to 30 V is typical in this lab. ELV circuits present a lower but not zero shock risk. The greater hazards at an ELV bench are often secondary: arc flash from a short circuit igniting flammable material, or the power supply itself being connected to 120 V line voltage internally.
Line voltage (120 V AC in the US) is present at every wall outlet and inside bench power supplies, oscilloscopes, and soldering stations. Line voltage can deliver lethal current through normal body resistance. Never probe inside an energized line-voltage enclosure without proper training, PPE, and authorization.
A ground fault occurs when current finds an unintended path to earth ground—often through a person's body. At the bench, ground-fault paths include:
Always inspect test leads before use. Replace any lead with cracked, melted, or abraded insulation. Never work with both hands inside a live circuit simultaneously—one-hand technique keeps the current path away from the heart.
Selecting the right PPE for the task is a professional responsibility. Using the wrong PPE gives false confidence without real protection.
| Task | Required PPE |
|---|---|
| Probing live 120 V circuits | Safety glasses; insulated gloves rated for the voltage; insulated test leads |
| Soldering | Safety glasses (splash/fume protection); proper ventilation |
| Working on de-energized, verified circuit | Safety glasses minimum; ESD wrist strap if working on static-sensitive components |
| ELV bench work (0–30 V, de-energized) | Safety glasses; ESD wrist strap when handling semiconductor devices |
Safety glasses protect against solder splash, component fragments from a short-circuit event, and wire ends during cutting. They are required any time you are at the bench.
Insulated gloves must be rated for the voltage level. Gloves rated for line voltage are bulky and reduce dexterity; they are used when working on or near energized line-voltage equipment.
ESD wrist straps protect components from electrostatic discharge—they do not protect you from shock. A wrist strap must never be worn while working on a live line-voltage circuit.
OSHA's Control of Hazardous Energy standard (29 CFR 1910.147) requires lockout/tagout procedures whenever equipment is being serviced or when an unexpected startup could injure workers. Although bench power supplies are lower energy than industrial machinery, the same disciplined sequence protects you and your lab partner.
The six-step LOTO sequence:
1. Notify — Inform all affected persons that the equipment is being shut down and why.
2. De-energize — Turn off the power supply using its normal shutdown procedure (power switch to OFF).
3. Isolate — Disconnect the supply from its energy source. For a bench supply, this means unplugging the line cord from the wall outlet.
4. Lock — Apply a personal padlock to the isolation point. In a lab setting this may mean looping the cord and locking it, or using a plug lockout device.
5. Tag — Attach an OSHA-compliant LOTO tag identifying who applied the lock, the date, and why.
6. Verify zero energy — Use a meter or the supply's own voltage display to confirm that the output and any stored energy (capacitors) have discharged to zero before touching the circuit.
Each technician working on the equipment applies their own lock. Locks are never shared. Only the person who applied a lock removes it.
Building these habits now prepares you for field work in telecommunications and electronics, where the stakes are higher and supervisors are not always present.