HLT-SURG65-04 · Lesson 8 · 21 clock hours · lab

Ophthalmic Surgery: Cataract Extraction, Vitrectomy, and Corneal Procedures

Objective. Students will set up a microsurgical sterile field for ophthalmic surgery, handle delicate ophthalmic instruments without damage, and describe the sequence of phacoemulsification cataract extraction.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

Ophthalmic Surgery: Cataract Extraction, Vitrectomy, and Corneal Procedures

Ophthalmic surgery is performed on some of the most delicate tissues in the human body. The surgical technologist working in an ophthalmic suite must master microsurgical technique, sterile field management on a very small scale, and a precise understanding of the procedural sequence. Errors that would be minor in general surgery can permanently damage vision. Patient safety depends on your attention to detail at every step.

The Ophthalmic Sterile Field

The ophthalmic mayo stand is set up differently from a general surgery tray. Instruments are tiny, lightweight, and easily damaged. Always handle them by the handle, never the tip. Lay each instrument flat with tips pointed away from the edge of the field and never stacked. Many programs use magnifying loupes during setup and case performance to verify instrument condition and placement. Before the case begins, inspect every tip under magnification for burrs, misalignment, or debris. A bent or contaminated microsurgical tip can cause corneal or lens-capsule injury.

The ophthalmic drape isolates the eye and provides a small sterile work surface. It typically incorporates an adhesive aperture that adheres directly to the periorbital skin, securing the drape and reducing the risk of it shifting during the procedure. Place irrigating solutions, viscoelastic syringes, and intraocular lens (IOL) supplies in an organized, consistent layout so you can retrieve any item without looking away from the field.

Cataract Extraction by Phacoemulsification

Cataract extraction is one of the most commonly performed surgical procedures in the United States. The standard modern technique is phacoemulsification (phaco), in which ultrasonic energy emulsifies the cloudy crystalline lens so it can be aspirated through a small self-sealing incision, usually less than 3 mm.

Procedural sequence:

1. Incision. The surgeon creates a corneal or scleral tunnel incision, often with a keratome or diamond blade. A paracentesis port is added for the second instrument.

2. Viscoelastic injection. An ophthalmic viscosurgical device (OVD), commonly called viscoelastic, is injected into the anterior chamber to protect the corneal endothelium and maintain space.

3. Capsulorhexis. A continuous curvilinear capsulorhexis (CCC) tears a circular opening in the anterior lens capsule. The instrument used is a cystotome needle or capsulorhexis forceps.

4. Hydrodissection. Balanced salt solution (BSS) is injected beneath the capsule to separate the lens nucleus from the capsule.

5. Phacoemulsification. The phaco handpiece, connected to the phacoemulsification unit via tubing, is introduced. Ultrasonic vibration at the tip emulsifies the nucleus while simultaneous irrigation (BSS) and aspiration maintain chamber pressure and remove lens material.

6. Irrigation/Aspiration (I/A). After the nucleus is removed, a separate I/A handpiece removes remaining cortical lens material.

7. IOL implantation. The posterior lens capsule is left intact as a scaffold. The surgeon inserts a foldable IOL using an IOL injector; the lens unfolds within the capsular bag.

8. OVD removal. Viscoelastic is aspirated to prevent postoperative pressure elevation.

9. Incision hydration/closure. The self-sealing corneal wound is hydrated with BSS; sutures are rarely needed for small-incision phaco.

Scrub technologist actions include preparing and loading the IOL injector immediately before use, flushing the phaco handpiece tubing to confirm flow and remove air, passing instruments with tips protected, and keeping the sterile field free of excess fluid.

Phacoemulsification Equipment Setup

The phaco machine combines ultrasound, irrigation, and aspiration in one console. The scrub tech is responsible for connecting the sterile tubing cassette to the handpiece and confirming the system is primed and bubble-free before the surgeon uses it. Always follow the manufacturer's instructions for the specific unit in your facility. Verify that irrigation fluid is flowing freely and that aspiration lines are not kinked. A clogged or air-filled line during the case can cause anterior chamber collapse, risking serious ocular injury.

Vitrectomy Overview

Vitrectomy removes the vitreous gel from the posterior segment of the eye and is indicated for retinal detachment, vitreous hemorrhage, macular conditions, and other posterior-segment pathology. Three small-gauge ports (commonly 23-, 25-, or 27-gauge) are placed through the pars plana. Instruments include the vitrector (cutting/aspiration handpiece), light pipe for intraocular illumination, and an infusion cannula to maintain intraocular pressure. The scrub tech sets up the vitrectomy pack, connects the infusion line, and ensures the light source cable is patent.

Corneal Procedures

Keratoplasty (corneal transplant) replaces diseased corneal tissue with donor tissue. Penetrating keratoplasty (PK) replaces the full thickness of the cornea; endothelial keratoplasty procedures such as DSAEK or DMEK replace only the posterior layers. Trephines are used to cut both donor and recipient tissue. Fine sutures (typically 10-0 nylon) require microsurgical needle holders and tying forceps. Handle donor tissue with extreme care; it must remain moist and be used within the time specified by the eye bank.

Safety Principles for Ophthalmic Surgery

Key terms10

PhacoemulsificationA cataract extraction technique using high-frequency ultrasonic vibration delivered through a handpiece tip to emulsify the crystalline lens nucleus so it can be aspirated through a small corneal incision.
CapsulorhexisA circular tear made in the anterior lens capsule, usually continuous and curvilinear (CCC), to provide access to the lens nucleus while preserving capsular support for the IOL.
Ophthalmic Viscosurgical Device (OVD)A viscoelastic gel-like substance injected into the anterior chamber to protect the corneal endothelium, maintain intraocular space, and stabilize ocular structures during surgery.
Intraocular Lens (IOL)An artificial lens implanted inside the eye, typically within the capsular bag, to replace the refractive power of the removed natural crystalline lens.
Irrigation/Aspiration (I/A)A two-function handpiece system that simultaneously infuses balanced salt solution to maintain anterior chamber depth while aspirating lens cortex or other material from the eye.
VitrectomyA posterior-segment surgical procedure in which the vitreous gel is mechanically cut and removed from the eye, typically through small-gauge pars plana ports, to treat retinal or vitreous pathology.
KeratoplastyA corneal transplant procedure in which diseased or damaged corneal tissue is replaced with donor tissue; may be full-thickness (penetrating) or layer-specific (endothelial or lamellar).
HydrodissectionThe injection of balanced salt solution beneath the anterior lens capsule to hydraulically separate the lens nucleus and cortex from the surrounding capsule before phacoemulsification.
Balanced Salt Solution (BSS)A sterile, isotonic intraocular irrigating solution formulated to be compatible with intraocular tissues; used to maintain chamber pressure and rinse structures during ophthalmic surgery.
TrephineA circular cutting instrument used in corneal surgery to excise a precise-diameter disc of corneal tissue from the donor or recipient eye.
In class: Students inventory and arrange an ophthalmic instrument tray on a draped mayo stand using magnifying loupes, identifying each microsurgical instrument by name and function before the instructor checks the arrangement. · Instructor demonstrates phacoemulsification handpiece connection and irrigation/aspiration setup; students practice connecting tubing to a simulated unit, flushing the system, and verifying flow before 'passing' the handpiece. · Using a written case card, students sequence the steps of a cataract extraction with IOL implantation on a flowchart, noting the instrument or supply used at each step and the scrub technologist's specific action.
Materials: Ophthalmic microsurgical instrument tray; magnifying loupes; phacoemulsification trainer or simulation unit; irrigation/aspiration tubing; IOL inserter (simulation); ophthalmic drape; cataract extraction flowchart template
Check: Instructor inspects arranged instrument tray against a labeled reference photo; all instruments must be present, correctly identified, and undamaged; tubing connection must be leak-free on instructor check; pass requires both stations complete.

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

Surgical Procedures
1. During phacoemulsification cataract extraction, which instrument is used to create the circular opening in the anterior lens capsule?
Sterile Technique and Instrumentation
2. When setting up an ophthalmic microsurgical instrument tray, the surgical technologist should FIRST:
Surgical Procedures
3. The PRIMARY purpose of injecting an ophthalmic viscosurgical device (OVD) into the anterior chamber during cataract surgery is to:
Equipment and Technology
4. Before the surgeon uses the phacoemulsification handpiece, the scrub surgical technologist must verify that the irrigation/aspiration tubing is:
Surgical Procedures
5. In which step of phacoemulsification cataract extraction does the scrub technologist load and pass the IOL inserter to the surgeon?
Surgical Procedures
6. A surgical technologist is preparing for a penetrating keratoplasty. Which instrument is used to cut the precise disc of tissue from the donor and recipient corneas?
Surgical Procedures
7. During a vitrectomy procedure, the infusion cannula placed through the pars plana serves which primary function?
Patient and Worker Safety
8. Before an intraocular lens is opened and delivered to the sterile field, the surgical technologist should: