Objective. The student will apply sterile drapes for at least three surgical site configurations — including extremity, abdominal, and head/neck setups — without contaminating the field or the patient prep site.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Sterile draping is the process of covering the patient and surrounding surfaces with sterile barriers so that only the intended operative site is exposed. Drapes create and define the sterile field; every action you take during draping either protects or destroys that field. Because a contaminated field places the patient at direct risk for surgical site infection (SSI), accuracy and discipline are not optional.
Handle drapes as little as possible. Each unnecessary movement increases the chance that a non-sterile surface will be touched or that the drape will fall below the table level, where it is considered contaminated.
Drapes are placed from the operative site outward. Begin closest to the incision site and work toward the periphery. This sequence protects the cleanest area first and moves contamination risk away from the wound.
Unfold away from yourself and away from the sterile field. Never reach across a sterile drape. Fan-fold drapes so they open in a controlled direction. Keep your gloved hands cuffed over the folded edge to protect them from contact with non-sterile surfaces.
Once placed, a drape is not repositioned toward the sterile field. A drape that has been moved away from the incision site may be adjusted further outward, but pulling it back toward the wound drags contamination with it. If a drape is placed incorrectly, it must be discarded and replaced.
Strike-through is contamination. Any fluid that soaks through a drape from a non-sterile surface to a sterile surface — or vice versa — renders that area non-sterile. Use impervious (fluid-resistant) drapes whenever fluid contact is likely.
Below table level is not sterile. Any portion of a drape that falls below the level of the operating table is considered contaminated and must not be brought back up.
1. The scrub technologist squares off the operative site using four sterile towels, placing them edge-to-edge around the incision area. Towels nearest the incision are placed first.
2. Towel clips or an adhesive incise drape secures the towels.
3. The laparotomy drape is opened and positioned over the squared site, with the fenestration aligned over the incision. The drape is unfolded toward the foot of the table, then toward the head, keeping hands cuffed.
4. The top portion of the drape covers the anesthesia screen; the foot end extends over and below the foot of the table.
1. The extremity is held elevated by a non-scrubbed team member or held by the scrub using a sterile impervious stockinette applied from the distal end upward.
2. A split sheet or bar drape is placed beneath the extremity once it is lowered onto the field.
3. Additional drapes cover the proximal body and adjacent surfaces.
4. The stockinette may be rolled back to expose the operative site, or cut with sterile scissors at the incision area.
1. A fluid-control head drape or split sheet is placed to isolate the head from the body.
2. A small fenestrated drape is centered over the operative eye or surgical site, with the opening exactly over the site.
3. Care is taken to keep drape material from obstructing the airway and to communicate with the anesthesia provider before placing any drape near the face.
Every member of the sterile team is responsible for identifying and announcing contamination immediately. If a breach occurs — a non-sterile hand reaching across the field, a drape falling below table level, or strike-through — you must:
1. State the breach calmly and clearly ("The field has been contaminated at the upper-left corner").
2. Isolate the contaminated drape or area.
3. Replace affected drapes before the procedure continues.
Silence is not acceptable. Patient safety depends on a culture in which any team member, regardless of experience level, speaks up without hesitation.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.