Objective. Students will accurately assemble two complete instrument trays from written count sheets, place instruments in correct tray sequence, complete all required documentation, and achieve a zero-error count on a final verification check.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Every sterile instrument tray that reaches an operating room represents a direct promise to the surgical team and the patient: the right instruments, in the right condition, in the right number, ready at the right moment. A missing clamp or a mislabeled tray can force a surgeon to pause mid-procedure, extend anesthesia time, or substitute an instrument that is not ideal. These are patient safety events, not just workflow inconveniences. Accurate tray assembly and complete documentation are therefore among the most critical skills a sterile processing technician performs.
A count sheet (also called a preference card or instrument list) is the authoritative reference for a specific procedure's instrument set. Every count sheet contains at minimum:
Read the quantity column carefully. A column may be divided into "Count In" and "Count Out" fields, both of which must match. Size notations such as "sm," "med," and "lg" are not interchangeable — verify each instrument against its description before placing it. If a count sheet lists "2 – Crile forceps, 5.5 in, curved," you must place exactly two of that specific instrument; a 6.25-inch Crile or a straight Crile does not satisfy the requirement.
Instruments are arranged in a logical, consistent order that mirrors how the scrub tech will hand them to the surgeon. Common practice places instruments in functional groups: cutting instruments together, clamping instruments together, retractors together, and so on. Within each group, instruments are typically ordered from smallest to largest or in the sequence they will be used.
On a stringer, instruments are loaded with tips facing the same direction, rings oriented consistently, and tip protectors applied to sharp or delicate tips to prevent damage during sterilization and to protect staff handling the tray. Instruments should lie flat and should not be stacked in ways that could trap air or moisture, which would compromise sterilization efficacy.
Tray baskets must not be overloaded. Crowded trays restrict steam or sterilant penetration and make accurate counting difficult. Follow your department's set-weight guidelines and the manufacturer's instructions for use (IFU) for both the tray system and the sterilizer.
Counting is a two-person process whenever possible. The assembler counts instruments as they are placed; a second person verifies the completed tray against the count sheet before wrapping or containering.
When counting, touch each instrument individually — do not count by eyeballing a group. Count one type of instrument completely before moving to the next line on the count sheet. If the count sheet lists 10 Kelly forceps and you can only locate 9, stop and resolve the discrepancy before proceeding. Never proceed with an incorrect count.
Documentation of a completed tray must include:
1. Tray or set name as it appears on the count sheet
2. Instrument count confirmation — signature or initials indicating count is correct
3. Assembler identification — your name or employee ID
4. Date of assembly
5. Inspection confirmation — that instruments were checked for cleanliness, function, and integrity
6. Verifier identification — the second person who confirmed the count
Any field left blank is an incomplete record. Incomplete records are a regulatory and accreditation concern: surveyors from bodies such as The Joint Commission review sterilization and set assembly records as part of infection control oversight.
Personal protective equipment (PPE): Wear cut-resistant gloves when handling sharps. Even in the clean assembly area, scalpel blades, trocars, and sharp retractors can cause injury.
Instrument inspection: Every instrument must be inspected during assembly, not just at decontamination. Check for visible soil, corrosion, broken tips, misaligned jaws, and non-functioning ratchets. A faulty instrument found in the OR wastes time and may compromise patient safety. Remove any instrument that fails inspection and follow your facility's repair or replacement procedure.
Scope of practice: Do not substitute an instrument that is not on the count sheet without authorization from a supervisor or the preference card owner (typically the surgeon or charge nurse). Unauthorized substitutions can create safety risks and are a documentation liability.
Preventing foreign body retention: In sterile processing, this principle mirrors the OR concern about retained surgical items. A complete, verified count is the department's contribution to ensuring nothing unintended ends up in a sterile field.
After assembly and documentation are complete, a final verification check is performed. The verifier works from the count sheet independently, touching each instrument, confirming size and type, and comparing the result to the documented count. Any discrepancy — missing instrument, wrong size, wrong quantity — is recorded on a verification form and must be resolved before the tray advances to wrapping and sterilization. A zero-error count is the only acceptable outcome for a tray that will be used on a patient.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.