Airway Suctioning Techniques

Objective. Students will perform oropharyngeal, nasopharyngeal, and endotracheal suctioning using correct sterile technique while monitoring patient SpO2 and keeping suction duration within evidence-based limits.

⚠ Pending professional review

This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.

VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.

Airway Suctioning Techniques

Airway suctioning is one of the most frequently performed — and most consequential — skills in respiratory therapy. When a patient cannot clear secretions effectively, those secretions obstruct airflow, impair gas exchange, and create a breeding ground for infection. Proper suctioning restores airway patency, but improper technique can cause hypoxemia, mucosal trauma, cardiac arrhythmias, or infection. Mastering suctioning means mastering both the mechanical steps and the patient-monitoring habits that go with them.

Indications for Suctioning

Suction only when there is a clinical reason to do so — not on a fixed schedule. Indications include: visible or audible secretions in the airway, decreased breath sounds caused by secretions, increasing airway pressures on a ventilator, a drop in SpO2 or oxygen saturation without another clear cause, and a patient's inability to cough effectively. Unnecessary suctioning stresses the patient and increases the risk of complications.

Oropharyngeal Suctioning

Oropharyngeal suctioning uses a rigid Yankauer catheter to clear the mouth and back of the throat. It is used for patients who cannot swallow or cough out oral secretions. This is a clean — not sterile — procedure, though you must still use good infection-control practices. Insert the Yankauer along the inside of the cheek toward the pharynx, apply suction during withdrawal, and limit each pass to approximately 10–15 seconds. Avoid triggering the gag reflex, and watch for the patient biting the catheter.

Nasopharyngeal Suctioning

Nasopharyngeal suctioning uses a flexible catheter passed through a naris to reach secretions in the nasal passages and upper pharynx. It is indicated when the oral route is inaccessible or contraindicated (for example, wired jaws). This procedure uses sterile technique. Lubricate the catheter with sterile water-soluble lubricant. Pass it gently along the floor of the nasal passage without applying suction; suction only during slow, rotating withdrawal. Each pass should last no longer than approximately 10–15 seconds. Avoid this route in patients with skull-base fractures, coagulopathy, or recent nasal surgery.

Endotracheal Suctioning — Open Technique

Open suctioning requires disconnecting the patient from the ventilator circuit briefly. Before you begin, pre-oxygenate the patient with 100% oxygen for approximately 30 seconds to build oxygen reserve and reduce the risk of suction-induced hypoxemia. Assemble a sterile field: sterile gloves, sterile suction catheter, and sterile saline if lavage is used (note that routine saline lavage is not recommended by current evidence). Set suction pressure to the lowest effective level — generally no more than 80–120 mmHg for adults, and lower for pediatric patients. Insert the catheter to the appropriate depth (to the carina, then withdraw slightly), apply suction only during withdrawal, and limit each pass to approximately 10 seconds. Reconnect the ventilator immediately after each pass and allow the patient to recover SpO2 before suctioning again. If SpO2 drops below 90% — or below the patient's baseline — stop suctioning and restore oxygenation.

Endotracheal Suctioning — Closed (In-Line) Technique

Closed suction catheters are housed in a protective plastic sleeve attached permanently to the ventilator circuit. The patient is never disconnected from the ventilator, so oxygenation and PEEP are maintained throughout. Closed technique is preferred for patients requiring high PEEP, FiO2 above 0.60, or who desaturate quickly. The mechanics are similar — insert without suction, suction only on withdrawal, limit each pass — but the closed system significantly reduces the risk of aerosolizing infectious secretions, making it the safer choice in airborne-precaution situations. After each use, flush the catheter sleeve with the manufacturer's recommended volume of sterile saline.

Suction Pressure and Catheter Size

For adult patients, suction pressure is generally set between 80 and 120 mmHg. Pressure higher than needed increases mucosal trauma and atelectasis. Choose a catheter no larger than half the internal diameter of the artificial airway. A catheter that is too large occludes the airway and dramatically worsens hypoxemia during suctioning.

Monitoring During Suctioning

Never leave the patient unobserved during suctioning. Watch SpO2 continuously. Monitor heart rate and rhythm: suctioning can stimulate the vagus nerve and cause a vasovagal response characterized by sudden bradycardia and hypotension. If this occurs, stop suctioning immediately, oxygenate the patient, and notify the supervising clinician. Document all findings — SpO2 before and after, suction pressure used, catheter size, secretion characteristics, and any adverse responses.

Sterile Technique: Non-Negotiable

Breaking sterile technique during endotracheal or nasopharyngeal suctioning introduces pathogens directly into the lower airway. Use a new sterile catheter for each suctioning episode. Do not allow the catheter to contact non-sterile surfaces. Keep your dominant (catheter-holding) gloved hand sterile at all times. Ventilator-associated pneumonia (VAP) is a serious and largely preventable complication; meticulous technique is your primary defense.

Documenting in the Lab Log

In clinical practice and in today's lab, thorough documentation is as important as the procedure itself. Record: indication for suctioning, suction pressure setting, catheter size and type, number of passes, duration of each pass, pre- and post-suction SpO2, description of secretions (color, consistency, estimated amount), and any adverse events and interventions. Accurate records protect patients and demonstrate professional accountability.

Key terms10

SpO2Peripheral oxygen saturation measured by pulse oximetry; used to monitor the patient's oxygenation status before, during, and after suctioning.
Sterile techniqueA set of practices — sterile gloves, sterile equipment, avoiding contact with non-sterile surfaces — used to prevent introduction of pathogens into the lower airway during endotracheal suctioning.
Open suction techniqueEndotracheal suctioning method that requires disconnecting the patient from the ventilator circuit; a new sterile catheter is used for each episode.
Closed (in-line) suction catheterA suction catheter housed in a protective sleeve permanently attached to the ventilator circuit, allowing suctioning without disconnection and without loss of PEEP or oxygenation.
Vasovagal responseA reflex mediated by the vagus nerve that can be triggered by suctioning, causing sudden bradycardia and hypotension; requires immediate cessation of suctioning and oxygenation.
Suction pressureThe negative pressure applied to draw secretions into the suction catheter; in adults generally limited to no more than 80–120 mmHg to minimize mucosal trauma.
Pre-oxygenationAdministration of 100% oxygen for approximately 30 seconds before suctioning to build oxygen reserve and reduce the risk of suction-induced hypoxemia.
Yankauer catheterA rigid, angled suction catheter used for oropharyngeal suctioning to clear secretions from the mouth and upper pharynx.
Ventilator-associated pneumonia (VAP)A pneumonia that develops in a patient who has been receiving mechanical ventilation; largely preventable through strict sterile technique and evidence-based care bundles.
Catheter depthThe distance the suction catheter is advanced into the artificial airway; typically advanced to the level of the carina and then withdrawn slightly before suction is applied.

Worked examples4

1. Selecting suction catheter size: A patient is intubated with a size 8.0 mm internal-diameter (ID) endotracheal tube. What is the maximum recommended catheter size (French) to use?
  1. Step 1 – Apply the standard rule: the catheter's outer diameter should be no more than half the inner diameter of the endotracheal tube.
  2. Step 2 – Convert the ETT ID to the same units. The ETT ID is 8.0 mm.
  3. Step 3 – Calculate half: 8.0 mm ÷ 2 = 4.0 mm maximum catheter outer diameter (OD).
  4. Step 4 – Convert mm OD to French: French size = OD in mm × 3. So 4.0 mm × 3 = 12 French.
  5. Step 5 – Select a catheter of 12 Fr or smaller. A 14 Fr catheter would exceed the limit and risk occluding the airway.
Answer: The maximum recommended catheter size is 12 French for an 8.0 mm ID endotracheal tube.
2. Suction duration check: The instructor's stopwatch shows you applied suction for 18 seconds on a single pass. Is this within the evidence-based limit, and what should you do next?
  1. Step 1 – Recall the evidence-based limit: each suction pass should last no longer than approximately 10 seconds (some sources allow up to 15 seconds); 10 seconds is the widely cited upper limit for minimizing hypoxemia and trauma.
  2. Step 2 – Compare: 18 seconds exceeds the 10-second limit.
  3. Step 3 – Immediate action: withdraw the catheter, reconnect the ventilator (open technique) or simply stop suctioning (closed technique), and provide supplemental oxygen.
  4. Step 4 – Monitor SpO2 and heart rate until values return to pre-suction baseline before considering another pass.
  5. Step 5 – Document the event, including duration and post-suction SpO2, in the lab log.
Answer: 18 seconds exceeds the recommended limit. Stop suctioning immediately, restore oxygenation, and allow the patient to recover before any additional pass.
3. Suction pressure conversion: Your suction gauge reads 100 mmHg. A colleague asks if this is within the adult limit. Convert 100 mmHg to cmH2O and confirm whether it is acceptable.
  1. Step 1 – Recall the conversion factor: 1 mmHg ≈ 1.36 cmH2O.
  2. Step 2 – Multiply: 100 mmHg × 1.36 = 136 cmH2O.
  3. Step 3 – Recall the adult guideline: suction pressure generally should not exceed 80–120 mmHg (approximately 108–163 cmH2O) for adults.
  4. Step 4 – 100 mmHg falls within the 80–120 mmHg range, so this setting is acceptable for an adult patient.
  5. Step 5 – Remind yourself to always use the lowest pressure that effectively clears secretions.
Answer: 100 mmHg (≈ 136 cmH2O) is within the accepted adult suction pressure range of 80–120 mmHg and is an appropriate setting.
4. Catheter depth estimation: A patient's endotracheal tube is marked at 22 cm at the lips, and the tube extends approximately 2 cm beyond the lips to the adapter. How would you estimate a safe catheter insertion depth to reach near the carina without traumatizing it?
  1. Step 1 – Identify the tube length inside the patient: the tube is marked 22 cm at the lip marking, meaning 22 cm of tube is inside the airway from that reference point.
  2. Step 2 – The catheter should be advanced just to the tip of the endotracheal tube (approximately 22 cm from the lips) and then 0.5–1 cm further to reach the carina area, after which you withdraw slightly before applying suction.
  3. Step 3 – Many institutions use a 'measured' or 'carina-level' approach: advance until resistance is felt (carina), withdraw 1 cm, then suction. Do not force the catheter past resistance.
  4. Step 4 – Always apply suction only during withdrawal, never during insertion.
  5. Step 5 – Document the insertion depth used in the lab log so subsequent caregivers are consistent.
Answer: Advance the catheter approximately to the tube tip depth (about 22 cm from the lips in this example), then withdraw 1 cm before applying suction to avoid direct carina trauma.

The math in this lesson1

Learners halve the ET tube inner diameter and convert millimeters to French catheter size by multiplying by 3.
N-Q.1
Brush up in the math halls at newSchoolWorks.com:
In class: Set up a sterile suction field and demonstrate open-technique endotracheal suctioning on a manikin with a simulated artificial airway in place; instructor calls out SpO2 readings and student responds appropriately. · Practice closed-suction-catheter technique on a ventilated manikin scenario, adjusting suction pressure and catheter depth to avoid simulated mucosal trauma, and recording each parameter on the lab log. · Complete a timed competency drill: perform oropharyngeal and nasopharyngeal suctioning back-to-back on the manikin, maintaining sterile field throughout, as the instructor introduces a simulated vasovagal response for the student to identify and manage.
Materials: Suction training manikin with artificial airway, suction machine with adjustable pressure, suction catheters (multiple sizes), open and closed suction catheter kits, sterile gloves, sterile saline, SpO2 simulator or pulse oximeter, lab log forms
Check: Skills checklist and lab log review: student maintains sterile technique throughout, keeps suction duration within evidence-based limits, and correctly identifies and responds to the simulated vasovagal response; pass = zero sterile technique breaks and zero critical safety errors.

Practice check8

Answer each question, then check it. Nothing is recorded; this is your own practice.

Patient Care and Clinical Practice
1. A patient on a mechanical ventilator requires endotracheal suctioning. Which action should the respiratory therapist perform FIRST?
Emergency and Acute Care Management
2. During open endotracheal suctioning, the patient's heart rate drops suddenly from 88 to 42 beats per minute and blood pressure falls. What is the most likely cause and the correct immediate response?
Equipment Selection and Maintenance
3. A size 7.5 mm ID endotracheal tube is in place. According to the one-half rule, what is the maximum suction catheter size (in French) that should be used?
Mechanical Ventilation and Airway Management
4. Which of the following BEST describes the primary advantage of closed (in-line) suction catheters over open suction technique?
Infection Control and Patient Safety
5. A respiratory therapy student breaks sterile technique by touching the suction catheter to the bed rail during endotracheal suctioning. What is the correct action?
Therapeutic Procedures
6. Which of the following suction pressure settings is generally considered appropriate for adult endotracheal suctioning?
Therapeutic Procedures
7. During nasopharyngeal suctioning, when should suction be applied?
Emergency and Acute Care Management
8. A patient's SpO2 drops from 96% to 87% during a suction pass that has lasted 12 seconds. Which action is MOST appropriate?