Objective. Students expose and evaluate standard horizontal and vertical bitewing radiographs of the posterior regions on a typodont, correctly positioning the receptor to capture interproximal contacts and alveolar bone levels.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Bitewing radiographs are among the most frequently exposed images in a dental office. They are designed to show the crowns of the maxillary and mandibular posterior teeth on a single image, along with the interproximal (contact) surfaces and the alveolar bone crest. Mastering bitewing technique is essential for passing the State Dental Radiology exam and for daily clinical practice.
Bitewing images serve two primary diagnostic purposes. First, they reveal interproximal caries — decay that forms between teeth where the explorer cannot easily reach. Second, they show the alveolar bone crest, allowing the dentist to assess bone height and detect early signs of periodontal (gum) disease. When interproximal contacts are truly open on the image, overlapping enamel does not hide potential decay. When the bone crest is visible just below the cementoenamel junction (CEJ), the dentist can evaluate bone levels accurately.
Horizontal bitewing radiographs are the standard for routine caries detection. The receptor (film or digital sensor) is positioned with its long axis running horizontally (parallel to the floor). A four-image series covering the premolar and molar regions is the most common adult survey. Horizontal bitewings show adequate crown detail and interproximal contacts, but the area of bone captured below the CEJ is limited.
Vertical bitewing radiographs are indicated when the dentist needs to evaluate bone levels in patients with known or suspected periodontal disease. The receptor is rotated 90 degrees so its long axis runs vertically. This orientation shows more of the root and alveolar bone apical to the CEJ while still opening the interproximal contacts. A four-image vertical series covers the same posterior regions as the horizontal series but captures significantly more bone height.
For both types, use a size 2 receptor for adults in the posterior regions. The receptor is held in a Rinn bitewing film holder (XCP-DS or similar) or secured with a commercial tab system. The patient bites down gently on the bite block or tab to stabilize the receptor. Key placement rules:
The central ray must pass through the interproximal contacts at a +8 to +10 degree vertical angulation (slightly downward from horizontal). This positive angle prevents the beam from projecting one tooth's crown over another (overlapping). Horizontal angulation is set so the beam is perpendicular to the receptor and directed through the contacts, not from a mesial or distal angle that would cause overlapping.
When using a Rinn holder, the aiming ring aligns the tubehead so that the beam angulation and direction are correct automatically — this is a major advantage over the free-hand tab technique, which demands careful angulation judgment by the operator.
| Error | Cause | Correction |
|---|---|---|
| Overlapping contacts | Incorrect horizontal angulation | Align beam perpendicular to contacts; use Rinn holder |
| Cone cut (missed receptor) | Tubehead not centered on receptor | Use aiming ring; check alignment before exposure |
| Bone crest not visible | Receptor placed too high in arch | Lower receptor; ensure 3–4 mm below occlusal plane |
| Blurry image | Patient or receptor moved during exposure | Stabilize receptor; remind patient to hold still |
| Dark (overexposed) image | Excessive kVp, mA, or time setting | Check exposure settings for patient size and receptor type |
| Light (underexposed) image | Insufficient exposure settings | Verify and adjust settings |
Always apply the ALARA principle (As Low As Reasonably Achievable). Before any exposure:
1. Drape the patient with a lead apron and thyroid collar.
2. Confirm the correct exposure settings for the patient's size and the receptor type (digital sensors generally require less radiation than conventional film).
3. Stand at least 6 feet from the tubehead and behind a barrier during exposure, or step out of the room.
4. Never hold the receptor in the patient's mouth during exposure — use a holder.
5. Verify that the patient is not pregnant or that the clinical need justifies exposure with appropriate shielding.
Following these steps protects both the patient and the dental assistant and reflects the professional and legal standards required for your State Dental Radiology license.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.