HLT-CNA36-03 · Lesson 3 · 8 clock hours · lab
Respiration, Blood Pressure, and Oxygen Saturation: Technique and Abnormal Recognition
Objective. Students will measure respiratory rate by unannounced 60-second observation, obtain manual and automated blood pressure readings within 4 mmHg of an instructor reference reading, and accurately read pulse oximetry values while identifying factors that cause false readings.
⚠ Pending professional review
This lesson, its worked examples and its practice questions has not yet been verified by a licensed clinician in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it to make decisions about any patient or medication. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Respiration, Blood Pressure, and Oxygen Saturation: Technique and Abnormal Recognition
Measuring and reporting vital signs accurately is one of the most important skills you will practice as a nursing assistant. The three signs covered in this lesson—respiratory rate, blood pressure, and oxygen saturation—together tell the care team whether a patient's heart, lungs, and circulation are working within safe ranges. An error in measurement or a missed abnormal value can delay treatment and harm the patient. Accuracy is not optional.
Measuring Respiratory Rate
Respiration is the rise and fall of the chest with each breath. One respiration equals one inhale plus one exhale. The normal adult rate is 12–20 breaths per minute at rest.
Why covert counting matters. Breathing is partly under conscious control. If a patient knows you are watching their breathing, they may unconsciously breathe faster or slower and give you a false number. The standard technique is to keep your fingers on the patient's wrist as though you are still counting the pulse, then shift your eyes to the chest and count silently for a full 60 seconds. Never count for 30 seconds and double; irregular breathing will not be detected that way.
What to observe. Note the rate (breaths per minute), depth (shallow, normal, or deep), and rhythm (regular or irregular). Noisy breathing, labored effort, or the use of neck and shoulder muscles to breathe are additional findings to report.
Abnormal respiratory rates:
- Tachypnea: rate above 20 breaths per minute
- Bradypnea: rate below 12 breaths per minute
- Apnea: complete absence of breathing—report immediately
Measuring Blood Pressure
Blood pressure (BP) is the force of blood against artery walls. It is recorded as two numbers: systolic (the pressure when the heart contracts) over diastolic (the pressure when the heart relaxes), written as mmHg. A typical normal adult range is roughly 90–119 mmHg systolic and 60–79 mmHg diastolic, though normal varies by the individual patient and their baseline.
Selecting and Applying the Cuff
Cuff size matters. A cuff that is too small will read falsely high; a cuff that is too large will read falsely low. The inflatable bladder inside the cuff should encircle at least 80 percent of the upper arm. Most clinical settings stock adult and large-adult cuffs—choose the correct one. Center the bladder over the brachial artery, align the cuff's artery marker with that landmark, and position the lower edge of the cuff about one inch (2–3 cm) above the antecubital crease. The patient's arm should rest at heart level, palm up.
Manual Auscultation Technique
1. Locate the brachial pulse with your fingertips.
2. Place the stethoscope diaphragm (or bell) lightly over the brachial artery—do not tuck it under the cuff.
3. Inflate the cuff to about 30 mmHg above the point where the radial pulse disappears, then release air at roughly 2–3 mmHg per second.
4. The first clear tapping sound you hear is the systolic reading. Note the gauge number.
5. The point at which sounds completely disappear is the diastolic reading.
6. Record to the nearest even number.
Automated Cuff
Automated devices apply the cuff the same way. Keep the arm still and at heart level during the reading; movement and talking cause errors. Cross-check automated readings against manual readings whenever results seem unexpected.
Factors That Affect Accuracy
- Talking, crossing legs, or a full bladder can raise systolic reading
- A recently used arm (IV site, dialysis shunt, mastectomy side) must not be used
- White-coat anxiety may elevate readings; allow the patient to rest for at least five minutes when possible
- Record which arm was used and the patient's position
Oxygen Saturation (SpO2)
A pulse oximeter uses light to estimate the percentage of hemoglobin in the blood that is carrying oxygen. Normal SpO2 in a healthy adult is 95–100%. Values below 95% require prompt reporting; values at or below 90% are generally considered a clinical emergency, though your facility's policy and the patient's baseline guide specific thresholds.
Applying the Oximeter
Clip-style sensors fit on a fingertip, usually the index or middle finger. The finger must be warm, dry, and free of dark nail polish or acrylic nails. Wait until the waveform on the device stabilizes before reading the number.
Causes of False or Inaccurate Readings
| Factor | Effect on reading |
|---|---|
| Dark nail polish or acrylic nails | May read falsely low |
| Cold or poorly perfused extremities | Weak signal; reading may be unreliable |
| Patient movement or shivering | Artifact; unstable waveform |
| Severe anemia | Device may read normal despite low oxygen-carrying capacity |
| Carbon monoxide exposure | Device cannot distinguish; may read falsely normal |
If the reading seems inconsistent with the patient's appearance (color, breathing effort), report your clinical observation to the nurse and note the factor you suspect.
Reporting with SBAR
When you find an abnormal value, report it to the nurse promptly using the SBAR format:
- Situation: what you observed right now
- Background: relevant patient context
- Assessment: what seems abnormal
- Recommendation: what you are requesting (a nurse to come assess the patient)
Example: *"The patient in room 4 has an SpO2 of 88% on room air. She is a 72-year-old with COPD. Her oxygen level is lower than her usual baseline of 93%. I need you to come assess her."
Safety Points
- Never take blood pressure on an arm with an IV line, a dialysis access site, or on the side of a mastectomy without a specific nurse order.
- Always report respiratory rates below 12 or above 20, BP readings significantly outside the patient's established baseline, and SpO2 below 95% (or per facility policy) without delay.
- Document exactly what the device displayed or what you counted—never round or estimate.
- Scope of practice: you measure and report; you do not diagnose or independently decide treatment.
Key terms9
Systolic pressureThe upper number in a blood pressure reading; the pressure in the arteries when the heart muscle contracts and pumps blood.
Diastolic pressureThe lower number in a blood pressure reading; the pressure in the arteries when the heart is at rest between beats.
AuscultationListening with a stethoscope to sounds produced by the body, used in manual blood pressure measurement to detect Korotkoff sounds.
SpO2The percentage of hemoglobin in arterial blood that is saturated with oxygen, measured non-invasively by a pulse oximeter.
TachypneaAn abnormally fast respiratory rate, defined as more than 20 breaths per minute in an adult at rest.
BradypneaAn abnormally slow respiratory rate, defined as fewer than 12 breaths per minute in an adult at rest.
Korotkoff soundsThe tapping sounds heard through a stethoscope over the brachial artery during manual blood pressure measurement; their first appearance marks systolic pressure and their disappearance marks diastolic pressure.
SBARA structured communication format standing for Situation, Background, Assessment, and Recommendation, used to report patient changes to the nurse clearly and efficiently.
Pulse oximeterA non-invasive clip-on device that uses light absorption to estimate the oxygen saturation of the blood (SpO2) and displays the value as a percentage.
Worked examples4
1. You inflate a cuff and the radial pulse disappears at 122 mmHg. At what pressure should you stop inflating, and why?
- The radial pulse disappears at 122 mmHg—this is your estimated systolic pressure.
- Add 30 mmHg to that number: 122 + 30 = 152 mmHg.
- Inflate the cuff to 152 mmHg before beginning slow deflation.
- This extra 30 mmHg ensures you do not miss the first Korotkoff sound if the true systolic is slightly higher than your estimate.
Answer: Stop inflating at 152 mmHg (30 mmHg above the point where the radial pulse disappeared).
2. You count 8 complete chest rises in 30 seconds while watching your patient's chest. What is the respiratory rate per minute, and is it normal?
- A 30-second count must be multiplied by 2 to convert to breaths per minute: 8 × 2 = 16 breaths per minute.
- Note: In practice you should count for a full 60 seconds for accuracy, but this calculation applies when a 30-second count is used.
- Compare 16 to the normal adult range of 12–20 breaths per minute.
Answer: 16 breaths per minute; this is within the normal adult range of 12–20 breaths per minute.
3. The instructor's reference blood pressure reading is 136/84 mmHg. Your reading is 141/80 mmHg. Does your reading pass the competency check?
- Calculate the systolic difference: 141 − 136 = 5 mmHg.
- The acceptable margin is within 4 mmHg; 5 mmHg exceeds that limit.
- Calculate the diastolic difference: 84 − 80 = 4 mmHg.
- The diastolic difference is exactly 4 mmHg, which meets the limit.
- Because the systolic reading exceeds the 4 mmHg margin, the overall reading does not pass, even though the diastolic is acceptable.
Answer: The reading does not pass. The systolic difference of 5 mmHg exceeds the allowed 4 mmHg margin.
4. A patient has an SpO2 of 91% displayed on the oximeter, but you notice she is wearing dark burgundy nail polish and her fingers feel cold. What steps should you take before reporting the value?
- Recognize that dark nail polish and cold extremities are both known causes of falsely low or unreliable SpO2 readings.
- If available, remove or reposition the sensor to a finger without polish, or use an earlobe or forehead sensor per your facility's equipment and policy.
- Warm the patient's hand briefly if possible to improve perfusion and signal quality.
- Wait for the waveform to stabilize, then re-read the device.
- Report the confirmed reading to the nurse along with your clinical observation (patient's color, breathing effort) and note which factors may have affected accuracy.
Answer: Attempt to improve conditions (different finger or site, warming the hand), re-read the stabilized value, then report the finding and the suspected interfering factors to the nurse using SBAR.
The math in this lesson1
Learners add 30 mmHg to the palpated systolic to set cuff inflation and convert 30-second counts to per-minute rates.
6.RP.3
In class: Blood pressure station rotation: students rotate through three stations—manual auscultation with sphygmomanometer and stethoscope, automated electronic cuff, and a practice station for locating the brachial artery and applying the cuff at the correct position; at each station students record two readings and compare with partner · Respiration and SpO2 paired lab: while one student counts the partner's respirations covertly (keeping hand on wrist as if continuing the pulse count), the other student applies the pulse oximeter; both record rate, depth, rhythm description, and SpO2; they then switch roles · Abnormal-values simulation: instructor presents three scenarios using an oxygen saturation trainer or a projected screen showing trending values; students identify the abnormal finding, name the likely contributing factor (nail polish, poor perfusion, movement artifact, cold extremities), and write the verbal report they would give the nurse using SBAR format (Situation, Background, Assessment, Recommendation)
Materials: Aneroid sphygmomanometers, stethoscopes, automated blood pressure cuffs (adult and large-adult sizes), pulse oximeters, SBAR reference card, lab recording worksheets, clock with second hand, Mosby's Textbook for Nursing Assistants, state CNA exam task list
Check: Instructor measures each student's blood pressure as reference, then student measures the same arm; reading must be within 4 mmHg systolic and 4 mmHg diastolic of instructor reading. Respiratory rate must be within 2 breaths per minute of simultaneous instructor count. SpO2 reading must match device display exactly. All three components must be passed in one supervised session; student may retry once on the same day with instructor coaching between attempts
Practice check8